A cooker should not be placed in rooms where there are gas stoves
or cookers, and in the bathroom, in buildings intended as laundries or
similar. The same applies for rooms or flats with air circulation or hot air
circulation with ventilation systems (air condition, extractor or kitchen
hoods), EXCEPT if such ventilation systems have safety mechanisms, which
sustain the air pressure above 4 Pa in a room, where the cooker is mounted
or in rooms which are in direct contact with exterior air.
It is recommended to place the cooker as close as possible to the
chimney hole, i.e. next to the chimney hole itself in order to avoid using
an additional smoke uptake pipe (
Figure 6a
)!
If you want to place the cooker between the kitchen elements, it is
necessary to ensure the safety distances (spacing between the cooker and
the kitchen element intended for air circulation - cooling) depending on
the temperature durability shown in the certificate of the material used
to make the kitchen element.
Here also you should take care on how to ensure access to a cooker for
maintenance and servicing.
4.2.
CHIMNEY PREPARATION AND CONTROL
Prior to cooker mounting, it is necessary to check the chimney – the
diameter, height, possible clogging or damages. The chimney must be
certified by an authorized local chimney-sweeper. The effective chimney
height must be at least 5 meters from the point of flue gases outlet
(
Figure 6b
).