Sengate PH-15FA Manual Instruction Download Page 4

 4

Web Site : http://www.sengate.com
E-Mail : service @ sengate.com

Designing / Manufacturing

Taiwan Security Net Co., Ltd.

Designing / Manufacturing

Taiwan Security Net Co., Ltd.

No.4-46, Fengren Rd., Renwu Dist., Kaohsiung City 814, Taiwan

TEL 886-7-3721111~4       FAX 886-7-3728650

 : 

No:A059B02-01

Unit : 

(

inch mm)

2.22

56.5)

"

 (

4.13

(104.85)

"

 

3.31

84.0)

"

 (

2.78

70.6)

"

 (

5.14

130.6)

"

 (

1.79 (45.6)

"

 

2.76  (70.0)

"

4.72

120.0)

"

 (

3.29

83.5)

"

 (

2.95

75.0)

"

 (

1.73

44.0)

"

 (

1.14

29.0)

"

 (

PH-15FA 

(

FLUSH Mount

)

PH-15SA 

(

SURFACE Mount

)

PH-15FA

PH-15SA

150ms (100~200ms)

-25

 ~  

+55

2.76"x 4.72"x 1.73"

    

(70.0x120.0x44.0 mm)

2.78"x 5.14"x 2.22"

       

(70.6x130.6x56.5 mm)

Indoor / Surface Mount        

6

TROUBLE-SHOOTING GUIDE

7

8

DIMENSIONS

SPECIFICATION

CONDITION

POSSIBLE CAUSE

 

REMEDY

Operation LED doesn’t light. 
(Transmitter)

Receiver 
when 

Alarm LED does not light

the beam is broken.

Receiver Alarm LED Alarm stays lit.

1. Disruption of power or inadequate power.
2. Bad wiring connection or broken wire, short.

1. Correct Power source.
2. Check and correct wiring.

1. Disruption of power or inadequate power.
2. Bad wiring connection or broken wire, short.
3. Reflection of beam is flooding receiver and  sent into  
    the receiver.

1. Correct Power source.
2. Check and correct wiring.
3. Remove reflecting object or change the
     installation location.

1. Bad wiring

 

Connection.

2. Unstable power source.
3. Shading object between Transmitter and Receiver.
4. The wiring of power machine is located nearby 
    Transmitter and Receiver.
5. Unstable installation of Transmitter and Receiver.
6. Optics of units are soiled.
7. Improper alignment.

1. Check and correct wiring.
2. Stabilize supply voltage.
3. Check and remove any possible obstacles.
4. Change environments or place for installation to 
    avoid the interference source.
5. Looking for proper installation location.
6. Clean the optics

 

with soft cloth.

7. Check and re-adjust.

Intermittent Alarm.

1. Alignment is off.
2. Shading object between Transmitter and Receiver.
3. Optics of units are soiled.

1. Check and adjust.
2. Check and remove any possible obstacles.
3. Clean the optics

 

with a soft cloth.

MODEL

 

NO

.

Supply Voltage

Standard Accessories

Environment Humidity

Ambient Temperature

Detection System

Response Time

Interruption Time

Alarm Output

Tamper Output

 

Indicator

 

LED

Functions

Wiring

Beam Adjustment

Mounting Position

Weight

Dimension 

(W X H X D)

Transmitter

Green Operation LED lights on when 

                    

 

with

 

power

 

on.

cover

 

is

 

opened

 

Receiver

Red Alarm LED lights on when an alarm is initiated. 

                 Yellow

 

Sensitive

 

LED lights on when beam reception

                 is attenuated.
                 Both Yellow and Red LED should be

 

off

 

as

 

correct

                

 

installation

.

   

Horizontal 

  

Vertical 

  

± 90°

± 5°

Please Note

      

1.This sensor is designed to detect intrusion and initiate an alarm

it

 

is

 

not

 

a

 

burglary

-

preventing

 

device

2.We are not responsible for damage, injury or losses caused by accident, theft, 

misuse, abnormal usage, faulty installation or improper maintenance.

3.

Specifications and design are subject to change without prior notice.

 
 

      

 

Acts of God (including inductive surge by lightning), abuse,  

         
      

6.9oz (195g)

      9.7oz (275g)

   

Indoor / Outdoor / Flush Mount

Screw  5/32" x 1  

 

Attenuation sheet X 1 pc

" X 4 pcs

   

Horizontal 

 

 

Vertical 

  

± 15° 

± 5°

   

AWG26 Wiring

   

   

Terminals

   95% (

Max.

)

   

3- step Alignment LED.

   

Dry Contact  NC. 0.2A/30VDC

   

None

  

Dry

 

contact

 

relay NC. / NO. 0.2A / 30VDC

 

  

(When the beam is blocked.)

 

1second

 

Pulsed

 

Infrared 1000pps

Infrared beam interruption system

10.5V~28VCD (Non-Polarity) 

Transmitter 12mA (16mA Max.) 
Receiver  24mA (26mA Max.) 

150 M

Indoor 15 M

Detection Range

Tenfold Distance

Beam Characteristics

Current Consumption

Reviews: