background image

ENGLISH 1/16

MI004202-E

This document is property of SENECA srl. Duplication and reproduction of it are forbidden (t

partial), if not authorized.

hough

Contents of present documentation refers to products and technologies described in it. Though we strive for reach perfection
continually, all technical data contained in this document may be modified or added due to technical and commercial needs.
It’s impossible eliminate mismatches and discordances completely. Contents of present documentation is anyhow subjected to
periodical revision. I

don’t hesitate to contact our structure or to write us to e-mail addresses as above

f you have any questions

mentioned.

SENECA s.r.l.

Via Austria, 26 – 35127 – PADOVA – ITALY
Tel. +39.049.8705355 – 8705359  Fax. +39.049.8706287
Internet site:

Technical assistance:

www.seneca.it

[email protected]

Commercial reference:

[email protected]

Chapter index

Page

1. Preliminary warnings

2

2. Description and characteristics

2.1 Module description
2.2 General characteristics and features

2

3. Technical specifications

3.1 Input
3.2 Outputs
3.3 Connections
3.4 Power supply
3.5 Module case
3.6 Environmental conditions

2

4. Preliminary instructions for use

4

5. Electrical connections

5.1 Safety measures before use
5.2 USB interface
5.3 Connections
5.4 Power supply
5.5 Universal input
5.6 Analog and relay outpu    strobe input

t /

4

6. Configuration

6.1

/

sur

Input selection   Mea

ing scale

6.2 START

END

and

setting at will

6.3 Output selection
6.4

through a PC

Configuration

6.5 Jumpers position
6.6 LED indications on the frontal panel

5

7. Purchase order code

8

8. Module layout

8

9. Decommissioning and disposal

8

USER MANUAL

Z Line

Z109REG2

-1

Universal converter module

with galvanic insulation

EN

Summary of Contents for Z109REG2

Page 1: ... Internet site Technical assistance www seneca it support seneca it Commercial reference sales seneca it Chapter index Page 1 Preliminary warnings 2 2 Description and characteristics 2 1 Module description 2 2 General characteristics and features 2 3 Technical specifications 3 1 Input 3 2 Outputs 3 3 Connections 3 4 Power supply 3 5 Module case 3 6 Environmental conditions 2 4 Preliminary instruct...

Page 2: ...M potentiometer value from W 500 to 100 k with the aid of a parallel resistence equal to 500 W W W Sampling frequency Variable from 240 sps with 11 bits resolution sign to 15 sps with 15 bits sign resolution typical values Response time 35 ms with 11 bits resolution 140 ms with 16 bits resolution measurement of voltage current potentiometer 1 PRELIMINARY WARNINGS 2 DESCRI ION ARA TERISTIC PT AND C...

Page 3: ...4 electromagnetic emission in industrial environment EN61000 6 2 electromagnetic immunity in industrial environment EN61010 1 safety Notes Use with copper conductor Use in Pollution Degree 2 Environment Power Supply must be Class 2 When supplied by an Isolated Limited Voltage and or Limited Current power supply a fuse rated max 2 5 A shall be installed in the field 1500 VA insulating voltage is am...

Page 4: ...ceeds 45 C and at least one of the severe operating conditions exists If the panel operating temperature exceeds 35 C and at least two of the severe operating conditions exist To satisfy the electromagnetic compliance requirements Use shielded cables for signals transmission The cable shield must be connected to an earth wire used specifically for instrumentation Avoid placing signal cables near p...

Page 5: ...ened in event of alarm 8 As an alternative to the relay output It is optoisolated and enables the current analog output 9 You can use it to multiplex a PLC input on n Z109REG2 In order to enable this input please see SETTINGS THROUGH INTERNAL JUMPERS V output 1 6 V mA output 1 6 A mA output RE TRANSMITTED OUTPUT Voltage Generated current 6 External power Supply current 7 1 6 A STROBE INPUT 9 RELAY...

Page 6: ...by a PC or by the programming push buttons Note DIP switches must be set while the module is powered down otherwise the module may be damaged SCALE n Thermocouple J Thermocouple K Thermocouple R Thermocouple S START END START END START END START END z z z 1 z z y 2 200 C 100 C 200 C 200 C 0 C 400 C 0 C 400 C z y z 3 100 C 200 C 100 C 400 C 100 C 600 C 100 C 600 C zy y 4 0 C 300 C 0 C 600 C 200 C 8...

Page 7: ...tware it is possible to set other normally fixed parameters in addition to start and end scale Additional input types digital filter normally disabled square root extraction normally disabled negative burn out normally positive alarm normally set as error signalling start and end scale of the analog output value of the analog output in case of error rejection programmable for 50 or 60 Hz mains fre...

Page 8: ... could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed information about the recycling of the product please contact your local city office waste disposal service of the retail store where you purchased this product 9 ECOMMISSIONING AND DISPOSAL D 8 E LAYOUT MODUL ORDER CODE SPECIFICATIONS CU A MICRO...