SETTING THE R-C TERMINATOR BY SW3 DIP SWITCH
Usually it is not necessary to use a terminator on the RS485 line unless this is inserted into the bus by some
other device (for example some modbus masters have a terminator that cannot be removed).
Terminator
DIP SW3
OFF
OFF
ON
ON
COMPLETE CONFIGURATION WITH EASY SETUP
To configure the device it is necessary to install the free "Easy Setup" software suite which can be downloaded
in section Z-SG2/Z-SG2-L of the
EASY SETUP MENU
Connect: Allows connecting the device to the PC.
New: Loads the default (factory) parameters onto the current project.
Open: Opens a previously saved project.
Save: Saves the current project
Read: Reads the current configuration from the device
Send: Sends the configuration (if the dip switches ARE NOT ALL OFF the device uses the configuration of the
RS485 by dip switch and NOT the one sent by the configuration)
Test and Calibration: Opens a new screen to read the main registers and allows you to send the commands
for the calibration of the load cell to the device.