ENGLISH - 5/8

MI004531-E

Before performing any operation is mandatory to read the full contents of this manual.
The module may only be used by qualified and skilled technicians in the field of electric
installation.                                Specific documentation is available for download at website:
www.seneca.it/products/z-umts.
Only  the  Manufacturer  is  authorized  to  repair  the  module  or  to  replace  damaged  parts. 
The  product  is  susceptible  to  electrostatic  discharge,  take  appropriate  countermeasures
during any operation.
No  warranty  is  guaranteed  in  connection  with  faults  resulting  from  improper  use,  from 
modifications or repairs carried out by Manufacturer-unauthorized personnel on the device, 
or if the content of this user Manual is not followed.

It is forbidden to place anything that could obstruct the ventilation slits.
It is forbidden to install the module near heat sources.

Severe operating conditions: -Powersupply > 30 V

, Powersupply > 26 V

 and

the module power the input sensor

.

 Separate the module at least 5 mm away from the 

other devices installed side by side if the module operate with:
- The operating temperature > 40°C and one of the severe operating condition exists.
- The operating temperature > 35°C and two of the severe operating conditions exist.

Disposal  of  electrical  &  electronic  equipment  (applicable  throughout  the  EU  and  other
countries with separate collection programs).

found on this product or on its

 The symbol 

packaging

,

indicates that this product it must be handed over to an applicable collection point 

 

for the recycling of electrical and electronic

 equipments.

PRELIMINARY WARNINGS

The module has an internal UPS that allows it to remain turned ON even without external power 
supply.         To turn off the module after removing the external power supply you can press the 
button PS1 on the right side of the module for at least 10 seconds.           When you release the 
button the PWR LED turns OFF in order to signal that the module is switched off.

MODULE SHUT DOWN PROCEDURE

MODEM 3G+

GSM / GPRS / EDGE / WCDMA / HSDPA / HSUPA / HSPA+ / DC-HSPA.

SUPPORTED
SYSTEM PROTOCOLS

FTP client,SMTP client, http, https, ModBUS TCP server,
ModBUS TCP client, ModBUS RTU master, ModBUS RTU slave.
For more information, please refer to the User Manual.

STORAGE UNIT

microSD and microSDHC Max. 32GB.

PROCESSOR

ARM 32bit

OPERATING SYSTEM

Real Time Multitasking

CHARACTERISTICS

Embedded Webserver and microSD Webserver

TECHNICAL SPECIFICATIONS

Summary of Contents for Z-LOGGER3

Page 1: ...ed in it This informations may be modified or integrated for technical and or commercial requirements SENECA s r l Headquarters Via Austria 26 35127 PADOVA ITALY Phone 39 049 8705355 8705359 Fax 39 04...

Page 2: ...F Network Searching or Missing Signal OFF Modem OFF LED SIGNALING ON FRONT PANEL Dimensions L H W 35 x 100 x 111 mm with terminals Weight 250 g Case Material PA6 black color 100 mm Z UMTS Connector Re...

Page 3: ...4 Energized 12V closed contact OFF Digital Input 4 De energized open contact PWR STS Green ON Z UMTS ON inactive log status ready Slow Blinking 2 8 sec ON 0 4 sec OFF Z UMTS active log status normal S...

Page 4: ...argeable batteries CONNECTIONS Removable three pole screw terminal pitch 5mm 2 for cable up to 2 5 mm rear IDC10 front RJ45 Micro USB and Antenna SMA POWERSUPPLY Voltage Power absorbed 19 40 V or 19 2...

Page 5: ...ure 40 C and one of the severe operating condition exists The operating temperature 35 C and two of the severe operating conditions exist Disposal of electrical electronic equipment applicable through...

Page 6: ...C10 connector into a free slot of DIN rail accessory as you can see in fig 1a the insertion is one way only because the connectors are polarized 3 To secure the module to the IEC EN 60715 DIN rail tig...

Page 7: ...lations transformers inverters motors induction ovens etc POWERSUPPLY The power supply must be connected to terminals 2 and 3 The supply voltage must be between 19 and 40V any polarity or between 19 a...

Page 8: ...ETH USB The module has a RJ45 socket on frontal panel Note Inserting the RJ45 10 100 Base T Ethernet plug make sure that the connector is securely latched or before inserting the cable into the RJ45...

Reviews: