background image

MI00562-2-EN

INSTALLATION MANUAL

1/4

INSTALLATION MANUAL

T203PM100-MU

T203PM300-MU

T203PM600-MU

SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel.  +39.049.8705359  -  Fax +39.049.8706287

WARNING

: The full content of this manual must be read before any operation. The module must only be used by 

qualified electricians. Specific documentation is available via QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to 

electrostatic discharges. Take appropriate measures during any operation.

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol   indicates conditions or actions that put the user's safety at risk.

The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

CONTACT INFORMATION

Technical support

[email protected]

Product information

[email protected]

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.

The content of this document corresponds to the described products and technologies.

Stated data may be modified or supplemented for technical and/or sales purposes.

DOCUMENTATION

T203PM600-MU

DOCUMENTATION

T203PM300-MU

DOCUMENTATION-

T203PM100-MU

Summary of Contents for T203PM100-MU

Page 1: ...opriate measures during any operation PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user s safety at risk The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment The warranty shall become null and void in the event of improper use or tampering with the module or...

Page 2: ... the magnetic field possibly if the zero error is greater than the declared error try a different arrangement or change orientation CAUTION USB PORT The front USB port allows easy connection to configure the device using the configuration software If it is necessary to restore the initial configuration of the instrument use the configuration software Through the USB port it is possible to update t...

Page 3: ...er manual INPUT Type of measurement AC DC TRMS or DC Bipolar Live 1000Vdc 290Vac Crest factor 100A 1 7 300A 1 9 600A 1 9 Pass band 1 4 kHz Overload 3 x IN continuous CAPACITY AC DC True RMS TRMS DC Bipolar DIP7 ON T203PM600 MU 0 600A 0 290Vac 600 600A 0 1000Vdc T203PM300 MU 0 300A 0 290Vac 300 300A 0 1000Vdc T203PM100 MU 0 100A 0 290Vac 100 100A 0 1000Vdc ANALOGUE OUTPUT Type 0 10 Vdc minimum load...

Page 4: ...GUE OUTPUT DIGITAL OUTPUT Connect just a pair of terminals for the measurement ELECTRICAL CONNECTIONS CAUTION Switch off the module before connecting the inputs and outputs To meet electromagnetic immunity requirements use properly insulated and dimensioned cables use shielded cables for signals connect the shield to a preferred instrumentation ground Keep shielded cables away from other cables us...

Reviews: