31
TD140-038.11 | Version 1.1 | 22 March 2019
7.2 Maintenance of the battery module
The battery modules are protected by an internal battery management system.
Maintenance
Function
Temperature
•
Permanent cell temperature monitoring by the BMS
•
Emergency stop with high or low temperatures
Deep discharge
•
Permanent cell monitoring by the BMS
•
Emergency charge to prevent deep discharge
•
Emergency stop during emergency charge error
Overcharge
•
Permanent cell monitoring by the BMS
•
Emergency stop with high voltages and high charge current
7.3 Cleaning
Material damages due to improper cleaning agent and
unallowed water usage!
Improper cleaning agents may scratch the surfaces of the system. Water may penetrate inside the
storage system and cause damages to the system.
ä
Do not use an abrasive cloth or sponge for cleaning the system.
ä
Do not use an abrasive or chlorine-containing cleaning agent.
ä
Clean the surface of the system with a humid cloth, but never a soaked one.
ä
Do not use a water jet for the system.
Carefully clean the outer panel of the system with a clean, soft humid cloth. For the removal of stubborn contaminants, use a
small quantity of a commercial detergent on the humid cloth.
8 Disposal
Never dispose the SENEC.Home Li and its components with the domestic waste.
Contact SENEC or your installation company. Ensure that this company takes care of the proper dismantling and disposal of the
system.