01/2017
- 6 -
Copyright © 2017, Fast ČR, a.s.
EN
Bagged Vacuum Cleaner
User's manual
■
Prior to using this appliance, please read the user’s manual thoroughly,
even in cases, when one has already familiarised themselves with
previous use of similar types of appliances. Only use the appliance in
the manner described in this user’s manual. Keep this user’s manual in
a safe place where it can be easily retrieved for future use.
■
We recommend saving the original cardboard box, packaging material,
purchase receipt and responsibility statement of the vendor or warranty
card for at least the duration of the legal liability for unsatisfactory
performance or quality. In the event of transportation, we recommend
that you pack the appliance in the original box from the manufacturer.
DESCRIPTION OF THE VACUUM CLEANER AND ITS ACCESSORIES
A1
Removable grill of the outflow
HEPA filter
A2
Washable outflow HEPA filter
is placed behind the grill.
A3
Automatic power cord
winding button
A4
Electronic suction power
control
A5
Full dust bag indicator
A6
Flexible hose connection hole
A7
Top cover locking and
releasing clip
A8
Integrated handle
A9
On/Off button of the vacuum
cleaner
A10
Rubber-coated rear travel
wheel
A11
Front swivel travel wheel
A12
Groove for the vertical
parking position
A13
Groove for the horizontal
parking position
A14
Dust bag*
A15
Dust bag holder
A16
Grill of the inflow micro-filter
A17
Washable inflow micro-filter
is placed in the grill.
A18
Flexible hose with mechanical
suction power control in the
handle
A19
Telescopic metal tube
A20
Floor nozzle with an
extensible brush
A21
2-in-1 brush and slot nozzle
Note*:
One disposable microfibre (nonwoven textile) bag is included.
PREPARING FOR USE
■
Make sure that the dust bag
A14
, inflow micro-filter
A17
and outflow
HEPA filter
A2
are properly installed.
■
Slide the end of the flexible hose
A18
fully into the hole
A6
.
Note:
When disassembling, it is necessary to press both locking clips at
the end of the hose
A18
while at the same time pulling the hose
A18
out of the hole
A6
.
■
On to the handle of the flexible hose
A18
, place the telescopic tube
A19
and set it to the required length as follows. Release the clip on the
telescopic tube
A19
and slide it towards the extensible part of the tube
A19
. After releasing the clip, set the length of the tube
A19
by sliding
its extensible part in or out. When the clip is released, it will lock in at
the set length.
■
Connect the floor nozzle
A20
to the free end of the telescopic tube
A19
.
The flap on the floor nozzle
A20
serves to extend and retract the brush.
■
The 2-in-1 brush and slot nozzle
A21
can be attached directly to the
handle of the flexible hose
A18
or to the telescopic tube
A19
.
USING THE VACUUM CLEANER
■
Pull on the power plug to wind out the required length of the power
cord and connect it to a power socket.
Attention:
The yellow mark on the power cord indicates the approaching
end of its length, and the red mark indicates the complete end of
its length. Do not attempt to pull the power cord past this mark.
■
To start the vacuum cleaner, press button
A9
. When vacuuming smooth
hard floor surfaces, extend the brush on the floor nozzle
A20
, and
retract the brush when vacuuming carpets. The slot nozzle can be used
for vacuuming hard to reach places and the brush nozzle for vacuuming
various types of furniture.
■
Suction power can be set using the electronic control slider
A4
or the
mechanical flap on the handle of the flexible hose
A18
.
■
When you have finished using the vacuum cleaner, turn it off by
pressing button
A9
and disconnect the power cord from the power
socket. To wind the power cord back into the vacuum cleaner, press
and hold button
A3
until its entire length is wound up.
Gently hold the
power cord with one hand while winding it up.
Note:
If the power cord is not wound up completely, release button
A3
, and pull the power cord out of the vacuum cleaner by
approximately 50 cm and then try again to wind it up.
PARKING POSITION OF THE VACUUM CLEANER
■
When not using the vacuum cleaner, you may put it in the parking
position. For the horizontal parking position, use the stopper on
the floor nozzle
A20
and the groove
A13
, see fig.
B1
. For the vertical
parking position, first set the shortest length of the telescopic tube
A19
.
Then put the vacuum cleaner in a vertical position, and slide the stopper
on the floor nozzle
A20
into the groove
A12
, see fig.
B2
.
MAINTENANCE AND CLEANING
■
Before cleaning it, always make sure that the vacuum cleaner is turned
off and disconnected from the power socket.
Changing the dust bag
■
The need to replace the dust bag is signalled by the indicator
A5
.
■
Release the clip
A7
and open the top cover of the vacuum cleaner.
Remove the used dust bag
A14
from the holder
A15
and insert a new
bag intended for this type of a vacuum cleaner in its place. If the dust
bag is not replaced in time, the vacuum cleaner’s suction power will
be reduced.
Cleaning and replacing the inflow micro-filter and the outflow HEPA
filter
■
Release the clip
A7
and open the top cover of the vacuum cleaner. Slide
the grill
A16
out of the vacuum cleaner and take the micro-filter
A17
out
of it. Rinse it under running lukewarm water and allow to dry naturally.
Then reinsert it and close the cover. In the event that the micro-filter
A17
is showing signs of wear or it is heavily soiled, replace it with a new one.
■
Release and remove the grill
A1
. Remove the HEPA filter
A2
from the
vacuum cleaner. In the case of light soiling, tap it out. We recommend
doing this away from living areas. In the event of greater soiling, wash
it under a weak current of running lukewarm water so that the water
washes the dirt out of the folds. Allow the HEPA filter
A2
to dry naturally,
then reinsert it and secure it in place with the grill
A1
. It is recommended
to replace the HEPA filter with a new one after 6 months of use.
■
When filters are soiled, their effectiveness is reduced, so do not neglect
their cleaning.
Attention:
Before putting the filters back into the vacuum cleaner, make
sure that they are completely dry.
Cleaning the flexible hose, telescopic tube, floor nozzle and the
2-in-1 attachment
■
If the vacuum cleaner accessories are soiled, remove them from the
vacuum cleaner and clean all dirt off of them (dust, hair, animal fur, etc.).
Cleaning the outer surface of the vacuum cleaner
■
Clean the outer surface using a dry or a lightly dampened cloth. Then
wipe it thoroughly dry.
■
For cleaning the vacuum cleaner, do not use steel wool, abrasive
cleaning products, solvents etc.
■
Do not submerge the vacuum cleaner under water or any other liquid
and do not rinse it under running water.
TECHNICAL SPECIFICATIONS
Rated voltage range ...................................................................................220−240 V
Rated frequency .............................................................................................50/60 Hz
Rated power input ...........................................................................................1 400 W
Maximum power input...................................................................................1 600 W
Electrical shock protection class ...............................................................................II
Noise level .........................................................................................................81 dB(A)
Dust bag capacity......................................................................................................... 3l
HEPA filter efficiency class ......................................................................................E12
Length of the power cord .................................................................................... 7 m
Operational radius .................................................................................................10 m