Sencor SVC 6000BK Manual Download Page 6

 

01/2017

- 6 -

 Copyright © 2017, Fast ČR, a.s.

EN

Bagged Vacuum Cleaner 

User's manual

 ■

Prior to using this appliance, please read the user’s manual thoroughly, 

even in cases, when one has already familiarised themselves with 

previous use of similar types of appliances. Only use the appliance in 

the manner described in this user’s manual. Keep this user’s manual in 

a safe place where it can be easily retrieved for future use. 

 ■

We recommend saving the original cardboard box, packaging material, 

purchase receipt and responsibility statement of the vendor or warranty 

card for at least the duration of the legal liability for unsatisfactory 

performance or quality. In the event of transportation, we recommend 

that you pack the appliance in the original box from the manufacturer.

DESCRIPTION OF THE VACUUM CLEANER AND ITS ACCESSORIES

A1 

Removable grill of the outflow 

HEPA filter

A2 

Washable outflow HEPA filter 

 

is placed behind the grill.

A3 

Automatic power cord 

winding button

A4 

Electronic suction power 

control

A5 

Full dust bag indicator

A6 

Flexible hose connection hole

A7 

Top cover locking and 

releasing clip 

A8 

Integrated handle 

A9 

On/Off button of the vacuum 

cleaner

A10 

Rubber-coated rear travel 

wheel

A11 

Front swivel travel wheel

 

A12 

Groove for the vertical 

parking position

A13 

Groove for the horizontal 

parking position

A14 

Dust bag*

A15 

Dust bag holder

A16 

Grill of the inflow micro-filter

A17 

Washable inflow micro-filter

 

is placed in the grill.

A18 

Flexible hose with mechanical 

suction power control in the 

handle

A19 

Telescopic metal tube

A20 

Floor nozzle with an 

extensible brush

A21 

2-in-1 brush and slot nozzle

Note*: 

One disposable microfibre (nonwoven textile) bag is included.

PREPARING FOR USE

 ■

Make sure that the dust bag 

A14

, inflow micro-filter 

A17

 and outflow 

HEPA filter 

A2

 are properly installed. 

 ■

Slide the end of the flexible hose 

A18

 fully into the hole 

A6

.

Note: 

When disassembling, it is necessary to press both locking clips at 

the end of the hose 

A18

 while at the same time pulling the hose 

A18

 out of the hole 

A6

.

 ■

On to the handle of the flexible hose 

A18

, place the telescopic tube 

A19

 and set it to the required length as follows. Release the clip on the 

telescopic tube 

A19

 and slide it towards the extensible part of the tube 

A19

. After releasing the clip, set the length of the tube 

A19

 by sliding 

its extensible part in or out. When the clip is released, it will lock in at 

the set length.

 ■

Connect the floor nozzle 

A20

 to the free end of the telescopic tube 

A19

The flap on the floor nozzle 

A20

 serves to extend and retract the brush. 

 ■

The 2-in-1 brush and slot nozzle 

A21

 can be attached directly to the 

handle of the flexible hose 

A18

 or to the telescopic tube 

A19

USING THE VACUUM CLEANER

 ■

Pull on the power plug to wind out the required length of the power 

cord and connect it to a power socket. 

Attention:

The yellow mark on the power cord indicates the approaching 

end of its length, and the red mark indicates the complete end of 

its length. Do not attempt to pull the power cord past this mark.

 ■

To start the vacuum cleaner, press button 

A9

. When vacuuming smooth 

hard floor surfaces, extend the brush on the floor nozzle 

A20

, and 

retract the brush when vacuuming carpets. The slot nozzle can be used 

for vacuuming hard to reach places and the brush nozzle for vacuuming 

various types of furniture.

 ■

Suction power can be set using the electronic control slider 

A4

 or the 

mechanical flap on the handle of the flexible hose 

A18

 ■

When you have finished using the vacuum cleaner, turn it off by 

pressing button 

A9

 and disconnect the power cord from the power 

socket. To wind the power cord back into the vacuum cleaner, press 

and hold button 

A3

 until its entire length is wound up.

 

Gently hold the 

power cord with one hand while winding it up.

Note: 

If the power cord is not wound up completely, release button 

A3

, and pull the power cord out of the vacuum cleaner by 

approximately 50 cm and then try again to wind it up.

PARKING POSITION OF THE VACUUM CLEANER

 ■

When not using the vacuum cleaner, you may put it in the parking 

position. For the horizontal parking position, use the stopper on 

the floor nozzle 

A20

 and the groove 

A13

, see fig. 

B1

. For the vertical 

parking position, first set the shortest length of the telescopic tube 

A19

Then put the vacuum cleaner in a vertical position, and slide the stopper 

on the floor nozzle 

A20

 into the groove 

A12

, see fig. 

B2

MAINTENANCE AND CLEANING

 ■

Before cleaning it, always make sure that the vacuum cleaner is turned 

off and disconnected from the power socket.

Changing the dust bag

 ■

The need to replace the dust bag is signalled by the indicator 

A5

 ■

Release the clip 

A7

 and open the top cover of the vacuum cleaner. 

Remove the used dust bag 

A14

 from the holder 

A15

 and insert a new 

bag intended for this type of a vacuum cleaner in its place. If the dust 

bag is not replaced in time, the vacuum cleaner’s  suction power will 

be reduced.

Cleaning and replacing the inflow micro-filter and the outflow HEPA 

filter

 ■

Release the clip 

A7

 and open the top cover of the vacuum cleaner. Slide 

the grill 

A16

 out of the vacuum cleaner and take the micro-filter 

A17

 out 

of it. Rinse it under running lukewarm water and allow to dry naturally. 

Then reinsert it and close the cover. In the event that the micro-filter 

A17

 

is showing signs of wear or it is heavily soiled, replace it with a new one.

 ■

Release and remove the grill 

A1

. Remove the HEPA filter 

A2

 from the 

vacuum cleaner. In the case of light soiling, tap it out. We recommend 

doing this away from living areas. In the event of greater soiling, wash 

it under a weak current of running lukewarm water so that the water 

washes the dirt out of the folds. Allow the HEPA filter 

A2

 to dry naturally, 

then reinsert it and secure it in place with the grill 

A1

. It is recommended 

to replace the HEPA filter with a new one after 6 months of use. 

 ■

When filters are soiled, their effectiveness is reduced, so do not neglect 

their cleaning.

Attention:

Before putting the filters back into the vacuum cleaner, make 

sure that they are completely dry. 

Cleaning the flexible hose, telescopic tube, floor nozzle and the  

2-in-1 attachment

 ■

If the vacuum cleaner accessories are soiled, remove them from the 

vacuum cleaner and clean all dirt off of them (dust, hair, animal fur, etc.).

Cleaning the outer surface of the vacuum cleaner

 ■

Clean the outer surface using a dry or a lightly dampened cloth. Then 

wipe it thoroughly dry. 

 ■

For cleaning the vacuum cleaner, do not use steel wool, abrasive 

cleaning products, solvents etc. 

 ■

Do not submerge the vacuum cleaner under water or any other liquid 

and do not rinse it under running water. 

TECHNICAL SPECIFICATIONS

Rated voltage range ...................................................................................220−240 V

Rated frequency .............................................................................................50/60 Hz

Rated power input ...........................................................................................1 400 W

Maximum power input...................................................................................1 600 W

Electrical shock protection class ...............................................................................II

Noise level  .........................................................................................................81 dB(A)

Dust bag capacity......................................................................................................... 3l

HEPA filter efficiency class ......................................................................................E12

Length of the power cord  .................................................................................... 7 m

Operational radius .................................................................................................10 m

Reviews: