- 12 -
02/2021
Copyright © 2021, Fast ČR, a.s.
USING THE STICK VACUUM CLEANER
1. Assemble the vacuum cleaner according to the instructions in the section
“
ASSEMBLY AND DISASSAMBLY OF THE STICK VACUUM CLEANER
”.
2. Insert the fully charged
A18
into the motor unit.
3. Press the switch
A12
and the vacuum cleaner starts.
4. The vacuum will operate while you hold the switch
A12
. As soon as it is released, the
operation of the vacuum cleaner stops automatically.
5. If you need to keep the vacuum cleaner running, push the switch lock
A11
towards
the handle
A13
. As soon as the switch lock
A11
is released, the operation of the
vacuum cleaner stops automatically.
USING THE WET CLEANING VACUUM CLEANING
1. Assemble the vacuum cleaner according to the instructions in the section
“
ASSEMBLY AND DISASSEMBLY OF THE WET CLEANING VACUUM CLEANER
”.
2. Insert the fully charged
A18
into the motor unit.
3. Press the lock
C6
to release the clean water tank and carefully remove the tank
C8
from the vacuum cleaner body – see picture
H1
.
4. Turn the tank lid
C7
counterclockwise and remove it from the tank
C8
. Pour clean
water into the tank
C8
minding the MAX mark – see picture
H2
. Place the lid
C7
back
and turn it clockwise to fix it.
5. To insert the clean water tank
C8
back, insert the lower part of the tank
C8
into the
vacuum cleaner body and gently press the upper part to the vacuum cleaner body
until it clicks – see picture
H3
.
Warning:
Never fill the tank
C8
over the MAX mark. There is a risk of damage
of the vacuum cleaner.
Before filling the tank
C8
make sure the wet cleaning vacuum
cleaner is correctly assembled, it is especially important the wet
cleaning nozzle
C15
is attached.
Water temperature you pour into the tank
C8
should not exceed
50°C.
If water starts accumulating in the collecting tank
C11
,
immediately turn the vacuum cleaner off, clean it before using it
again.
Do not tilt the wet cleaning attachment
C4
over 30 °.
Note:
You can add a small amount of neutral cleaning agent with mild foaming
effects into the tank
C8
.
Warning:
Do not use the TURBO function when you use the vacuum
cleaner for wet cleaning.
6. Press the switch
A12
and the vacuum cleaner starts. The vacuum will operate
while you hold the switch
A12
. As soon as it is released, the operation of the
vacuum cleaner stops automatically. If you need to keep the vacuum cleaner
running, push the switch lock
A11
towards the handle
A13
. As soon as the switch
lock
A11
is released, the operation of the vacuum cleaner stops automatically.
7. To start the wet cleaning function, press the
C18
button and the water will be
released from the tank
C8
through the nozzle
C15
into the soft rotary brush
C23
which will wipe the dirt from the floor. At the same time, the dirty water will be
vacuumed back into the vacuum cleaner and through the collecting tank
C11
, it
will be discharged into the dirty water tank
C14
.
8. If you release the switch
A12
, the water supply from the tank
C8
will be also
interrupted and you will have to press the
C18
button when turning the vacuum
cleaner on again.
9. You can use the wet cleaning vacuum cleaner for vacuuming split water, wine, or
other wet dirt from the floor. In such case, there is no need to press the
C18
button
to dose water. Dirty water will be vacuumed into the vacuum cleaner and through
the collecting tank
C11
, it will be discharged into the dirty water tank
C14
.
10. After finishing the vacuuming, empty the dirty water tank
C14
. Follow the
instructions in the section “
Cleaning and maintenance”
.
Lights of the wet cleaning nozzle
Lights
Definition
White light is lit.
Water dose is on.
No light is lit.
Water dose is stopped.
Red light flashes.
Dirty water tank is full.
TURBO FUNCTION
■
If you need to increase the power of the vacuum cleaner to the maximum, press
the TURBO
A7
button. The vacuum cleaner starts at the maximum power. Once you
need to lower the power, press the TURBO
A7
button again.
STORAGE UNDER NORMAL USE
■
The charging base
D13
is designed to store the motor unit and accessories in it and
to charge one battery
A18
at the same time. Insert the motor unit into the charging
base
D13
.
■
There is a groove at the back of the charging base
D13
to attach the floor nozzle
B4
or wet cleaning nozzle
C15
. Both the floor nozzle
B4
and the wet cleaning nozzle
C15
are provided with stoppers which you insert into the groove.
■
You can attach the selected accessories you use the most often to the two pins
located at the back of the charging base
D13
.
CLEANING AND MAINTENANCE
■
Before cleaning, always make sure the vacuum cleaner is switched off. Remove the
battery
A18
from the motor unit.
CLEANING THE MOTOR UNIT AND ACCESSORIES
■
Use a soft cloth, lightly dampened in a lukewarm water, to clean the outer parts of
the vacuum cleaner. Do not use abrasive cleaning agents, solvents, or dissolving
agents, otherwise the unit surface may be damaged.
CLEANING THE STICK VACUUM CLEANER
Empty the dust container
■
It is advised to empty the dust container
A15
after each use. However, if the dirt level
reaches the MAX mark, it is necessary to empty the dust container
A15
immediately.
1. Remove the accessory from the motor unit.
2. Place the motor unit above the waste bin with the dust container bottom facing
down.
3. Press the
A16
button and the dust container bottom is released and it opens – see
picture
I1
.
4. This will empty the container content directly into the waste bin.
5. Use your hand to close the container bottom. It clicks once correctly fitted – see
picture
I2
.
Cleaning the dust container
■
Clean the dust container
A15
regularly to prevent unpleasant odours.
1. Remove the accessory from the motor unit and empty the dust container
A15
according to the instructions above.
2. Press the button
A17
to release the dust container and carefully remove it from the
motor unit – see picture
I3
.
3. Wipe the inner walls of the dust container
A15
using a light dampened soft sponge.
Dry with a clean cloth.
4. Turn the filter unit
A14
counter clockwise and remove it from the motor unit.
Remove the dirt from the filter unit above the waste bin. You can use a cleaning
brush if needed – see picture
I4
.
Note:
Cleaning brush is not a part of the packaging.
5. Attach the filter unit
A14
to the motor unit (align the symbol of open lock with an
arrow on the motor unit) and turn the filter unit
A14
clockwise until the arrow points
to the closed lock symbol.
6. Attach the container
A15
to the motor unit. The container
A15
clicks once correctly
assembled.
Cleaning and change of the outflow filter
■
It is advised to clean the outflow filter
A9
regularly to ensure proper vacuum cleaner
operation. Depending on how often you use the vacuum cleaner, change the
outflow filter
A9
once every 3 or 6 months.
1. Press the locks
A10
on both sides of the cover
A8
and pull the cover with outflow
filter out – see picture
I5
.
2. Remove the dirt from the filter
A9
. If the filter
A9
is heavily soiled, rinse it under
running clean water. Leave it to dry and then insert it back into the motor unit – see
picture
I6
.
Warning:
Never insert wet or damp filter
A9
into the motor unit! Always
wait until it is completely dry. Do not use any appliances, e.g., hair
dryer, or never place it to dryer to dry the filter
A9.
Avoid drying
on the direct sunshine.
Cleaning and change of the inflow filters
■
It is advised to clean inflow filters
A3
and
A5
regularly to ensure proper vacuum
cleaner operation. Depending on how often you use the vacuum cleaner, change
the inflow filters
A3
and
A5
once every 3 or 6 months. Always change both filters
at the same time.
1. Hold the cover
A2
and pull it upwards.
2. Remove the outer inflow filter
A5
from the holder
A4
and beat it above the waste
bin.
3. Remove the inner inflow filter
A3
from the holder
A4
and beat it above the waste
bin. If the inner inflow filter
A3
is heavily soiled, rinse it under running clean water.
Leave it to dry and then insert it back into the holder
A4
.
4. Place the outer inflow filter
A5
onto the holder
A4
and then insert the assembled
inflow filter into the motor unit until it clicks.
Cleaning the floor nozzle
■
It is necessary to clean the floor nozzle
B4
regularly to ensure the desired and stable
suction power.
1. Remove the floor nozzle
B4
from the vacuum cleaner and turn it upside down.
2. Turn the lock
B10
to release the side cover.
3. Carefully remove the rotary brush
B11
– see picture
I7
.
Summary of Contents for SVC 0825WH
Page 5: ...02 2021 5 Copyright 2021 Fast R a s 9 10 11 12 4 5 6 7 8 2 3 1 B...
Page 7: ...02 2021 7 Copyright 2021 Fast R a s 1 2 3 5 6 4 8 10 11 12 13 7 9 D E1 E3 E2 E4...
Page 8: ...02 2021 8 Copyright 2021 Fast R a s F G1 G2 G3 H1 H2 H3...
Page 9: ...02 2021 9 Copyright 2021 Fast R a s I1 I2 I3 I4 I5 I6 I7 I8 I9...
Page 10: ...02 2021 10 Copyright 2021 Fast R a s J1 J2 J3 J4 J5 J6 J9 J10 J7 J8...