Sencor SVC 0825WH Manual Download Page 12

- 12 -

 

02/2021

 Copyright © 2021, Fast ČR, a.s.

USING THE STICK VACUUM CLEANER

1. Assemble the vacuum cleaner according to the instructions in the section 

ASSEMBLY AND DISASSAMBLY OF THE STICK VACUUM CLEANER

”.

2. Insert the fully charged 

A18

 into the motor unit.

3. Press the switch 

A12

 and the vacuum cleaner starts.

4.  The vacuum will operate while you hold the switch 

A12

. As soon as it is released, the 

operation of the vacuum cleaner stops automatically.

5. If you need to keep the vacuum cleaner running, push the switch lock 

A11

 towards 

the handle 

A13

. As soon as the switch lock 

A11

 is released, the operation of the 

vacuum cleaner stops automatically.

USING THE WET CLEANING VACUUM CLEANING

1. Assemble the vacuum cleaner according to the instructions in the section 

ASSEMBLY AND DISASSEMBLY OF THE WET CLEANING VACUUM CLEANER

”.

2. Insert the fully charged 

A18

 into the motor unit.

3. Press the lock 

C6 

to release the clean water tank and carefully remove the tank 

C8 

from the vacuum cleaner body – see picture 

H1

.

4. Turn the tank lid 

C7

 counterclockwise and remove it from the tank 

C8

. Pour clean 

water into the tank 

C8

 minding the MAX mark – see picture 

H2

. Place the lid 

C7

 back 

and turn it clockwise to fix it.

5. To insert the clean water tank 

C8

 back, insert the lower part of the tank 

C8

 into the 

vacuum cleaner body and gently press the upper part to the vacuum cleaner body 

until it clicks – see picture 

H3

.

Warning:

Never fill the tank 

C8

 over the MAX mark. There is a risk of damage 

of the vacuum cleaner.

Before filling the tank 

C8

 make sure the wet cleaning vacuum 

cleaner is correctly assembled, it is especially important the wet 

cleaning nozzle 

C15

 is attached.

Water temperature you pour into the tank 

C8 

should not exceed 

50°C.

If water starts accumulating in the collecting tank 

C11

immediately turn the vacuum cleaner off, clean it before using it 

again.

Do not tilt the wet cleaning attachment 

C4 

over 30 °.

Note:

You can add a small amount of neutral cleaning agent with mild foaming 

effects into the tank 

C8

.

Warning:

Do not use the TURBO function when you use the vacuum 

cleaner for wet cleaning. 

6.  Press the switch 

A12

 and the vacuum cleaner starts. The vacuum will operate 

while you hold the switch 

A12

. As soon as it is released, the operation of the 

vacuum cleaner stops automatically. If you need to keep the vacuum cleaner 

running, push the switch lock 

A11

 towards the handle 

A13

. As soon as the switch 

lock 

A11

 is released, the operation of the vacuum cleaner stops automatically.

7.  To start the wet cleaning function, press the 

C18

 button and the water will be 

released from the tank 

C8

 through the nozzle 

C15

 into the soft rotary brush 

C23

 

which will wipe the dirt from the floor. At the same time, the dirty water will be 

vacuumed back into the vacuum cleaner and through the collecting tank 

C11

, it 

will be discharged into the dirty water tank 

C14

.

8.  If you release the switch 

A12

, the water supply from the tank 

C8

 will be also 

interrupted and you will have to press the 

C18 

button when turning the vacuum 

cleaner on again.

9.  You can use the wet cleaning vacuum cleaner for vacuuming split water, wine, or 

other wet dirt from the floor. In such case, there is no need to press the 

C18 

button 

to dose water. Dirty water will be vacuumed into the vacuum cleaner and through 

the collecting tank 

C11

, it will be discharged into the dirty water tank 

C14

.

10.  After finishing the vacuuming, empty the dirty water tank 

C14

. Follow the 

instructions in the section “

Cleaning and maintenance”

.

Lights of the wet cleaning nozzle

Lights

Definition

White light is lit.

Water dose is on.

No light is lit.

Water dose is stopped.

Red light flashes.

Dirty water tank is full.

TURBO FUNCTION

 ■

If you need to increase the power of the vacuum cleaner to the maximum, press 

the TURBO 

A7 

button. The vacuum cleaner starts at the maximum power. Once you 

need to lower the power, press the TURBO 

A7

 button again.

STORAGE UNDER NORMAL USE

 ■

The charging base 

D13

 is designed to store the motor unit and accessories in it and 

to charge one battery 

A18 

at the same time. Insert the motor unit into the charging 

base 

D13

.

 ■

There is a groove at the back of the charging base 

D13

 to attach the floor nozzle 

B4

 

or wet cleaning nozzle 

C15

. Both the floor nozzle 

B4

 and the wet cleaning nozzle 

C15

 are provided with stoppers which you insert into the groove.

 ■

You can attach the selected accessories you use the most often to the two pins 

located at the back of the charging base 

D13

.

CLEANING AND MAINTENANCE

 ■

Before cleaning, always make sure the vacuum cleaner is switched off. Remove the 

battery 

A18

 from the motor unit.

CLEANING THE MOTOR UNIT AND ACCESSORIES

 ■

Use a soft cloth, lightly dampened in a lukewarm water, to clean the outer parts of 

the vacuum cleaner. Do not use abrasive cleaning agents, solvents, or dissolving 

agents, otherwise the unit surface may be damaged.

CLEANING THE STICK VACUUM CLEANER

Empty the dust container

 ■

It is advised to empty the dust container 

A15 

after each use. However, if the dirt level 

reaches the MAX mark, it is necessary to empty the dust container 

A15 

immediately.

1. Remove the accessory from the motor unit.

2. Place the motor unit above the waste bin with the dust container bottom facing 

down.

3. Press the 

A16 

button and the dust container bottom is released and it opens – see 

picture 

I1

.

4. This will empty the container content directly into the waste bin.

5. Use your hand to close the container bottom. It clicks once correctly fitted – see 

picture 

I2

.

Cleaning the dust container

 ■

Clean the dust container 

A15

 regularly to prevent unpleasant odours.

1. Remove the accessory from the motor unit and empty the dust container 

A15 

according to the instructions above.

2. Press the button 

A17

 to release the dust container and carefully remove it from the 

motor unit – see picture 

I3

.

3.  Wipe the inner walls of the dust container 

A15 

using a light dampened soft sponge. 

Dry with a clean cloth.

4. Turn the filter unit 

A14 

counter clockwise and remove it from the motor unit. 

Remove the dirt from the filter unit above the waste bin. You can use a cleaning 

brush if needed – see picture 

I4

.

Note:

Cleaning brush is not a part of the packaging.

5. Attach the filter unit 

A14 

to the motor unit (align the symbol of open lock with an 

arrow on the motor unit) and turn the filter unit 

A14 

clockwise until the arrow points 

to the closed lock symbol. 

6. Attach the container 

A15 

to the motor unit. The container 

A15 

clicks once correctly 

assembled.

Cleaning and change of the outflow filter

 ■

It is advised to clean the outflow filter 

A9 

regularly to ensure proper vacuum cleaner 

operation. Depending on how often you use the vacuum cleaner, change the 

outflow filter 

A9 

once every 3 or 6 months.

1. Press the locks 

A10 

on both sides of the cover 

A8 

and pull the cover with outflow 

filter out – see picture 

I5

.

2. Remove the dirt from the filter 

A9

. If the filter 

A9 

is heavily soiled, rinse it under 

running clean water. Leave it to dry and then insert it back into the motor unit – see 

picture 

I6

.

Warning:

Never insert wet or damp filter 

A9

 into the motor unit! Always 

wait until it is completely dry. Do not use any appliances, e.g., hair 

dryer, or never place it to dryer to dry the filter 

A9. 

Avoid drying 

on the direct sunshine.

Cleaning and change of the inflow filters

 ■

It is advised to clean inflow filters 

A3

 and 

A5

 regularly to ensure proper vacuum 

cleaner operation. Depending on how often you use the vacuum cleaner, change 

the inflow filters 

A3 

and 

A5 

once every 3 or 6 months. Always change both filters 

at the same time.

1. Hold the cover 

A2

 and pull it upwards.

2. Remove the outer inflow filter 

A5

 from the holder 

A4

 and beat it above the waste 

bin.

3. Remove the inner inflow filter 

A3

 from the holder 

A4

 and beat it above the waste 

bin. If the inner inflow filter 

A3

 is heavily soiled, rinse it under running clean water. 

Leave it to dry and then insert it back into the holder 

A4

.

4. Place the outer inflow filter 

A5 

onto the holder 

A4

 and then insert the assembled 

inflow filter into the motor unit until it clicks.

Cleaning the floor nozzle

 ■

It is necessary to clean the floor nozzle 

B4 

regularly to ensure the desired and stable 

suction power.

1. Remove the floor nozzle 

B4 

from the vacuum cleaner and turn it upside down.

2. Turn the lock 

B10

 to release the side cover.

3. Carefully remove the rotary brush 

B11 

– see picture 

I7

.

Summary of Contents for SVC 0825WH

Page 1: ...02 2021 1 Copyright 2021 Fast R a s EN Cordless StickVacuum Cleaner All in One Translation of the original manual SVC 0825WH...

Page 2: ...ial dangers Children must not play with the vacuum cleaner Cleaning and maintenance performed by the user must not be performed by unsupervised children If the power adapter is damaged it must be repl...

Page 3: ...ile materials items e g broken glass needles pins etc flour wall plaster cement and other building materials larger pieces of paper or plastic bags which can easily block the suction hole Vacuuming of...

Page 4: ...02 2021 4 Copyright 2021 Fast R a s SVC 0825WH A 3 4 5 10 11 12 13 1 2 14 1718 15 16 6 7 8 19 9...

Page 5: ...02 2021 5 Copyright 2021 Fast R a s 9 10 11 12 4 5 6 7 8 2 3 1 B...

Page 6: ...02 2021 6 Copyright 2021 Fast R a s 1 2 3 4 9 10 11 12 13 14 6 7 8 5 16 21 22 23 15 17 18 19 20 C...

Page 7: ...02 2021 7 Copyright 2021 Fast R a s 1 2 3 5 6 4 8 10 11 12 13 7 9 D E1 E3 E2 E4...

Page 8: ...02 2021 8 Copyright 2021 Fast R a s F G1 G2 G3 H1 H2 H3...

Page 9: ...02 2021 9 Copyright 2021 Fast R a s I1 I2 I3 I4 I5 I6 I7 I8 I9...

Page 10: ...02 2021 10 Copyright 2021 Fast R a s J1 J2 J3 J4 J5 J6 J9 J10 J7 J8...

Page 11: ...k C5 and remove the wet cleaning nozzle C15 3 ASSEMBLY AND DISASSEMBLY OF THE VACUUM CLEANER WITH ACCESSORIES To ensure perfect cleaning of your home you can attach any of the supplied accessories to...

Page 12: ...tor unit into the charging base D13 There is a groove at the back of the charging base D13 to attach the floor nozzle B4 or wet cleaning nozzle C15 Both the floor nozzle B4 and the wet cleaning nozzle...

Page 13: ...1 Place the filter unit C9 into the collecting tank C11 so that the holes around the filter unit C9 are aligned with the protrusions around the collecting tank C11 Then turn the filter unit C9 clockw...

Page 14: ...ling hand over these appliances to determined collection points Alternatively in some European Union states or other European countries you may return your appliances to the local retailer when buying...

Reviews: