- 7 -
03/2021
Copyright © 2021, Fast ČR, a.s.
EN
Humidifier
User's manual
■
Prior to using this appliance, please read the user's manual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of
appliances. Only use the appliance in the manner described in this user’s manual.
Keep this user's manual in a safe place where it can be easily retrieved for future use.
■
We recommend saving the original cardboard box, packaging material, purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event
of transportation, we recommend that you pack the appliance in the original box
from the manufacturer.
DESCRIPTION OF THE APPLIANCE
A1
Steam outlet nozzle
A2
Pillow for applying drops of
aromatic oil
A3
Water tank
A4
Filling opening cap on the water
tank
A5
Ultrasound disc
A6
Brush
A7
Air outlet
A8
Water tank illumination
A9
Button for On / Off / Operating
mode selection / Low water level in
tank indicator
A10
Base unit
A11
Anti-slip feet
A12
Power adapter
BEFORE FIRST USE
■
Before first use, take the appliance and its accessories out of the packaging material
and remove all promotional labels and stickers. Check that neither the appliance nor
any of its parts is damaged.
Filling the water tank
1. Check that the power adapter
A12
is disconnected.
2. Carefully take the water tank
A3
off the base unit
A10
.
3. Turn the water tank
A3
upside down and screw out the cap
A4
– see figure
B1
.
4. Pour clean cold water into the water tank
A3
– see figure
B2
.
5. Screw on the cap
A4
– see figure
B3
. Check that it is tightened firmly to prevent
water from leaking. Turn the water tank over
A3
so that the cap
A4
is pointing
downwards. If no water is leaking from the water tank
A3
, then the cap
A4
is
properly tightened.
6. Put it back on the base
A10
.
Connecting the power adapter
1. Insert the connector of the power adapter
A12
into the socket located at the rear of
the base unit
A10
– see figure
B4
.
2. Then insert the power adapter plug into a properly grounded power socket. The
humidifier is now ready for use.
Turning on the humidifier
1. Position the humidifier on a dry, even and water-resistant surface approx. 15 cm
away from walls and other objects. Ensure that there is sufficient free space around
the appliance. Do not place the humidifier on carpets, towels, blankets or other
absorptive materials.
2. Press button
A9
to start the humidifier. The humidifier will automatically start at low
speed and the illumination
A8
will be turned off.
Selecting an operating mode
■
Repeatedly press button
A9
to select one of the following operating modes.
Operating mode
Number of times
button A9 is
pressed
Setting
Water tank
illumination
Mode 1
Once
Low speed
Off
Mode 2
Twice
Low speed
On
Mode 3
Three times
High speed
On
Mode 4
Four times
High speed
Off
■
If button
A9
is pressed five times, the humidifier will turn off.
Note:
The water tank illumination colour changes automatically when the
illumination is turned on.
Low water level indicator
■
When the water level falls below the set level, the backlight of button
A9
will change
from blue to red and the humidifier will turn off automatically.
■
Add water if necessary. Prior to adding water, check that the humidifier is turned
off and that the power adapter
A12
is disconnected from the power socket. Then
you may continue according to the instructions in section "
Filling the water tank
".
Warning:
Never remove the water tank
A3
from the base unit
A10
while
the humidifier is running. This would automatically turn off the
humidifier and creates a risk of its irreversible damage, risk of
a dangerous situation arising and risk of injury.
Setting the direction of outflowing steam
■
The direction of the outflowing steam can be adjusted within an angle of 360 ° by
turning the steam outlet nozzle
A1
.
Aromatic oil
■
This humidifier has been designed to enable the use of aromatic oil in it. Next to the
steam outlet there is a special pillow
A2
, on to which drops of aromatic oil can be
applied.
ALWAYS USE ONLY 3 DROPS OF AROMATIC OIL
.
Warning:
Under no condition pour aromatic oil into the water tank
A3
or
into the base unit
A10
. This risks damaging the inner parts of the
humidifier.
CLEANING AND MAINTENANCE
■
Disconnect the adapter power plug from the power socket and allow the appliance
to cool down before cleaning it.
■
Adhere to the following instructions relating to the cleaning and maintenance of the
humidifier. Otherwise its performance may be negatively affected and undesirable
microorganisms may multiply inside.
Warning:
To prevent the risk of injury by electrical shock, do not submerge
the appliance, the adapter or its power cord in water or any
another liquid.
Clean after every use
1. Turn off the humidifier and disconnect the power adapter
A12
from the power
socket.
2. Take the water tank
A3
off the base unit
A10
and also remove the nozzle
A1
.
3. Screw off the cap
A4
and pour any remaining water out into the sink or down the
drain.
4. Rinse out the water tank using clean water and remove any dirt or deposits out of it.
5. Wipe it with a dry wiping cloth.
6. To clean the base unit
A10
and the nozzle
A1
, use a clean soft wiping cloth lightly
dampened in warm water. Wipe dry using a clean wiping cloth.
Note:
For cleaning, do not use cleaning products with an abrasive effect,
solvents, etc. that could damage the appliance. No part of this appliance
is intended for washing in a dishwasher.
Warning:
Do not leave water inside the water tank
A3
for an extended
period of time.
Removing limescale deposits
■
Depending on the hardness of the water that is used and the frequency of use,
we recommend regularly removing water scale deposits, at least once per week.
Limescale deposits can negatively affect the operation of the humidifier and its
lifetime.
■
In the event that your water is too hard, we recommend using distilled water.
1. Turn off the humidifier and disconnect the power adapter
A12
from the power
socket.
2. Take the water tank
A3
off the base unit
A10
and also remove the nozzle
A1
.
3. Screw off the cap
A4
and pour any remaining water out into the sink or down the
drain.
4. Fill the water tank
A3
with one cup of white vinegar and allow it to act for 15
minutes. Using a cleaning brush with soft bristles, you can remove limescale
deposits that have accumulated inside the water tank
A3
.
5. Pour out the contents of the water tank
A3
into a sink or down the drain and rinse
out the water tank
A3
using clean cold water.
6. Wipe it with a dry wiping cloth.
Cleaning the ultrasound disc
1. Turn off the humidifier and disconnect the power adapter
A12
from the power
socket.
2. Take the water tank
A3
off the base unit
A10
.
3. For cleaning the ultrasound disc
A5
, use only the supplied cleaning brush
A6
.
4. Carefully wipe the disc
A5
with the cleaning brush
A6
to remove any dust and dirt
that is on it – see figure
C
.
Warning:
Do not push on the cleaning brush
A6
so that you do not scratch
or damage the disc
A5
.