- 7 -
04/2021
Copyright © 2020, Fast ČR, a.s.
EN
Humidifier
User's manual
■
Prior to using this appliance, please read the user's manual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of
appliances. Only use the appliance in the manner described in this user’s manual.
Keep this user's manual in a safe place where it can be easily retrieved for future use.
■
We recommend saving the original cardboard box, packaging material, purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event
of transportation, we recommend that you pack the appliance in the original box
from the manufacturer.
DESCRIPTION OF THE APPLIANCE
A1
Steam outlet
A2
Pillow for applying drops of
aromatic oil
A3
Water tank
A4
Filling opening cap on the water
tank
A5
Power cord
A6
Power indicator light / low water
level in water tank
A7
Power control knob / off / speed
selection
A8
Water tank illumination button
A9
Base unit
A10
Anti-slip feet
A11
Cleaning brush
A12
Air outlet
A13
Ultrasound disc
BEFORE FIRST USE
■
Before first use, take the appliance and its accessories out of the packaging material
and remove all promotional labels and stickers. Check that neither the appliance nor
any of its parts is damaged.
Filling the water tank
1. Make sure that the power cord
A5
is disconnected from the power socket.
2. Carefully take the water tank
A3
off the base unit
A9
– see figure
B1
.
3. Turn the water tank
A3
upside down and screw out the cap
A4
– see figure
B2
.
4. Pour clean cold water into the water tank
A3
– see figure
B3
.
5. Screw on the cap
A4
– see figure
B4
. Check that it is tightened firmly to prevent
water from leaking. Turn the water tank over
A3
so that the cap
A4
is pointing
downwards. If no water is leaking from the water tank
A3
, then the cap
A4
is
properly tightened.
6. Put it back on the base unit
A9
.
Turning the humidifier on / off and selecting the speed
1. Position the humidifier on a dry, even and water-resistant surface approx. 15 cm
away from walls and other objects. Ensure that there is sufficient free space around
the appliance. Do not place the humidifier on carpets, towels, blankets or other
absorptive materials.
2. Insert the power plug
A5
into a properly grounded power socket.
3. Turn the control knob
A7
to the right to turn on the humidifier. Power on is indicated
by the emission of steam.
4. Turn the control knob
A7
to the right to set the speed. Turn it towards "MAX" to
increase the speed, turn it away from "MAX" to reduce the speed.
5. When not using the humidifier, turn the control knob
A7
to the left to "ON/OFF" to
turn it off.
Power indicator light / low water level in water tank
■
The indicator light
A6
is lit green when the humidifier is turned on.
■
When the water level in the water tank
A3
falls, the indicator light
A6
will be lit red.
Likewise, the illumination of the water tank will also turn off.
■
Add water to the water tank
A3
according to the instructions in section "
Filling the
water tank
". When operation resumes, the illumination of the water tank will remain
turned off.
Warning:
Never remove the water tank
A3
from the base unit
A9
while
the humidifier is running. This would automatically turn off the
humidifier and creates a risk of its irreversible damage, risk of
a dangerous situation arising and risk of injury.
Turning on / off the water tank illumination
■
The water tank illumination can only be turned on / off when the humidifier is
turned on, and in the following order:
■
First press of button
A8:
the illumination of the water tank is turned on and the
colours will change in 5-second intervals.
■
Second press of button A8
: the illumination of the water tank will turn on in the
colour in which button
A8
was pressed.
■
Third press of button A8:
the illumination of the water tank will turn off.
Setting the direction of outflowing steam
■
The direction of the outflowing steam can be adjusted within an angle of 360 ° by
turning the steam outlet nozzle
A1
.
Aromatic oil
■
This humidifier has been designed to enable the use of aromatic oil in it. Next to the
steam outlet there is a special pillow
A2
, on to which drops of aromatic oil can be
applied.
ALWAYS USE ONLY 3 DROPS OF AROMATIC OIL
.
Warning:
Under no condition pour aromatic oil into the water tank
A3
or
into the base unit
A9
. This risks damaging the inner parts of the
humidifier.
CLEANING AND MAINTENANCE
■
Disconnect the power plug from the power socket and allow the appliance to cool
down before cleaning it.
■
Adhere to the following instructions relating to the cleaning and maintenance of the
humidifier. Otherwise its performance may be negatively affected and undesirable
microorganisms may multiply inside.
Warning:
To prevent the risk of injury by electrical shock, do not submerge
the appliance, the power plug or its power cord in water or any
another liquid.
Clean after every use
1. Turn off the humidifier and disconnect the power cord
A5
from the power socket.
2. Take the water tank
A3
off the base unit
A9
.
3. Screw off the cap
A4
and pour any remaining water out into the sink or down the
drain.
4. Rinse out the water tank using clean water and remove any dirt or deposits out of it.
5. Wipe it with a dry wiping cloth.
6. To clean the base unit
A9
, use a clean soft wiping cloth lightly dampened in warm
water. Wipe dry using a clean wiping cloth.
Note:
For cleaning, do not use cleaning products with an abrasive effect,
solvents, etc. that could damage the appliance. No part of this appliance
is intended for washing in a dishwasher.
Warning:
Do not leave water inside the water tank
A3
for an extended
period of time.
Removing limescale deposits
■
Depending on the hardness of the water that is used and the frequency of use,
we recommend regularly removing water scale deposits, at least once per week.
Limescale deposits can negatively affect the operation of the humidifier and its
lifetime.
■
In the event that your water is too hard, we recommend using distilled water.
1. Turn off the humidifier and disconnect the power cord
A5
from the power socket.
2. Take the water tank
A3
off the base unit
A9
.
3. Screw off the cap
A4
and pour any remaining water out into the sink or down the
drain.
4. Fill the water tank
A3
with one cup of white vinegar (approx. 200 ml) and allow
it to act for 15 minutes. Using a cleaning brush with soft bristles, you can remove
limescale deposits that have accumulated inside the water tank
A3
.
5. Pour out the contents of the water tank
A3
into a sink or down the drain and rinse
out the water tank
A3
using clean cold water.
6. Wipe it with a dry wiping cloth.
Cleaning the ultrasound disc
1. Turn off the humidifier and disconnect the power cord
A5
from the power socket.
2. Take the water tank
A3
off the base unit
A9
.
3. For cleaning the ultrasound disc
A13
, use only the supplied cleaning brush
A11
.
4. Carefully wipe the disc
A13
with the cleaning brush
A11
to remove any dust and dirt
that is on it – see figure
C.
Warning:
Do not push on the cleaning brush
A11
so that you do not scratch
or damage the disc
A13
.
Storage
■
When not using the appliance for an extended period of time, disconnect the power
cord
A5
from the socket, allow the appliance to cool down and clean it according
to the instruction above.
■
Before storing it, check that the appliance and all its accessories are thoroughly
clean and dry, and that there is no water in the water tank
A3
.
■
Store the appliance in a dry, clean and well-ventilated location not exposed to
extreme temperatures and out of children's reach.