EN-6
EN
Wall Mount Fan
SFG 4055WH
2014
06/2014
FAN ASSEMBLY
Take the fan out of the packaging material and check that you have all the parts illustrated in the
chapter Description of the fan. Apart from the parts mentioned above, the deliver comes with
a set of two screws and dowels for fastening the holder A
9
to the wall and a screw with a nut for
fastening the joint on the outer band A
1
.
Place the motor unit A
8
on an even dry and stable surface. Place the rear protective grill A
6
on to
the motor shaft A
7
. Push the grill A
6
towards the motor unit A
8
ensuring the lugs on the front
part of the motor unit A
8
pass through the round holes in the central part of the rear grill A
6
.
Use the nut A
5
to secure the grill A
6
to the motor unit A
8
.
On to the motor shaft A
7
place the fan blades A
4
and push them in the direction of the motor
unit A
8
. Make sure that the motor shaft A
7
with the T-shaped end, slides correctly into the cut-
outs in the centre part of the fan blades A
4
. Connect the fan blades A
4
to the shaft A
7
using the
fastening nut A
3
. When you spin the fan blades A
4
by hand, they must rotate freely. If they jam
up, it is necessary to disassemble the fan blades A
4
and to connect them again to the shaft A
7
.
On to the rear grill A
6
place the outer band A
1
ensuring that the grill A
6
is seated in the groove
of the band A
1
around the entire perimeter. Fasten the band joint A
1
using the supplied screw
and nut. Do not fully tighten the screw so that it is still possible to insert the front protective grill
A
2
into the outer band A
1
.
Insert the front protective grill A
2
into the second groove in the band A
1
. As soon as the grill
A
2
snaps into the groove in the band A
1
around the entire perimeter, tighten the screw used to
secure the joint of band A
1
. The joint must be fi rm to prevent the movement of grills A
2
and A
6
.
MOUNTING THE FAN ON A WALL
Choose a suitable location for the installation of the fan on the wall. The fan must be located within
reach of a wall power socket and at a suffi cient distance from curtains, drapes, sources of heat, etc.
Press the holder A
9
against the wall so that the hook for hanging the fan points upwards and the
screw holes are aligned on a single vertical axis. Mark out the points for drilling the holes on the
wall and place the holder A
9
aside. Drill holes into the wall and insert the dowels into them. Press
the holder A
9
against the wall and screw the screws (2 pcs) into the dowels to fasten the holder
A
9
to the wall. Hang the fan on the holder A
9
.
Note:
Before drilling holes into the wall, make sure that in the marked out points there is no electrical
wiring or other utility lines.
OPERATING THE FAN
Connect the fan to a power socket.
1. Setting the speed and turning off the fan
1.1 Set the timer A
qa
to the ON position. To set the speed of the fan turn dial A
qs
to position
1, 2 or 3 (low, medium and high speed). The fan will run at the set speed.
1.2 To turn off the fan, turn the dials A
qa
–
qs
to the OFF position.
1.3 The control panel A
q;
is equipped with a string (SPEED) A
qd
, which makes it possible to comfortably
control the dial A
qs
. Each time that the string (SPEED) A
qd
is pulled, the setting of dial A
qs
will
change in the following sequence: OFF
1
2
3
OFF
1
2
3.
2. Setting the auto-off timer
2.1 The timer A
qa
can be used to set the automatic shut off time for the fan in the range 0–120
minutes. Use the dial A
qs
to select a fan speed. Use the timer A
qa
to set the desired shut off time.
The fan will run at the set speed and after the set time elapses it will turn itself off automatically.
The timer A
qa
will switch to the OFF position.