Sencor SAC MT1220C Translation Of The Original Manual Download Page 4

 

10/2019

- 4 -

 Copyright © 2019, Fast ČR, a.s.

 

Disconnect the appliance from the power socket by pulling on the plug, 

never pulling on the power cord. Otherwise, this could damage the power 

cord or the socket.

 

In the event that the power cord or power plug are damaged in any way, do 

not use the appliance.

 

Store the appliance in a vertical position. It may be transported in a vertical 

position or tilted on the sided. If you have already used the appliance, check 

that all the condensate has been drained. After transporting it, wait at least 

1 hour before using the appliance.

 

Do not use the appliance if it is not working correctly, if it has been damaged 

or has been submerged in water. To avoid a hazardous situation arising, do 

not repair the device yourself or modify it in any way. Have all repairs or 

adjustments performed at an authorised service centre. By tampering with 

the appliance, you risk voiding your legal rights arising from unsatisfactory 

performance or quality warranty.

 

Installation must be performed in accordance with the installation instructions. 

Incorrect installation may result in a water leak, injury by electrical shock or fire.

 

To prevent the risk of fire or injury by electrical shock, do not use this appliance 

with a timer or any another similar device that could spontaneously start 

this appliance.

 

The appliance must be installed in accordance with national electrical codes.

 

Only use this product for the purposes that are described in this user’s manual. 

Otherwise, this may result in damage or excessive noise and vibrations.

 

Use only the accessories and components that are supplied together with 

the appliance and the tools explicitly intended for its installation. The use 

of non-standard parts and accessories may result in a water leak, injury by 

electrical shock, fire, injury or damage to property.

 

DO NOT ADJUST the length of the power cord of the unit and do not use an 

extension cord for its power supply.

 

DO NOT CONNECT the unit to a power socket to which other electrical 

appliances are already connected. The incorrect selection of an electrical 

power supply may result in a fire or injury by electrical shock.

 

Do not cover the cable with a carpet. Do not place carpets, fillets or any 

other floor coverings on the power cord. Do not locate the cable underneath 

furniture or appliances. Lead the cable where nothing will ride over it and 

where nobody can trip over it. If this occurs, immediately disconnect the 

unit from the power socket.

Summary of Contents for SAC MT1220C

Page 1: ...10 2019 1 Copyright 2019 Fast R a s EN Portable Air Conditioner Translation of the original manual SAC MT9020C SAC MT9021C SAC MT1220C SAC MT1224CH SAC MT1225CH...

Page 2: ...must not play with the appliance If the power cord is damaged it must be replaced by an authorised service centre or by another similarly qualified person this will prevent the creation of a dangerou...

Page 3: ...r to connecting the appliance to a power socket make sure that the appliance is correctly assembled according to the instructions in this user s manual Do not touch the appliance with wet or damp hand...

Page 4: ...fire To prevent the risk of fire or injury by electrical shock do not use this appliance with a timer or any another similar device that could spontaneously start this appliance The appliance must be...

Page 5: ...90 Carefully study any warnings For defrosting and cleaning do not use any other tools than those recommended by the manufacturer This appliance must be located in an environment that has no continuou...

Page 6: ...ertifies this person s competence to work with refrigerants in accordance with the specific assessment of the association for this sector Maintenance tasks must be performed solely on the basis of the...

Page 7: ...10 2019 7 Copyright 2019 Fast R a s 1 2 3 A 8 9 7 4 5 6 10 1 B 2 3 4 5...

Page 8: ...10 2019 8 Copyright 2019 Fast R a s 2 C 8 1 3 4 5 6 7 9 10 11 12 13 1 D 4 2 7 5 6 3 8 9 10 s E...

Page 9: ...ource located in the room Do not locate the portable air conditioner in a room with high humidity e g laundry Note Do not use the portable air conditioner to cool a room where computer servers etc are...

Page 10: ...rs set in 30 minute intervals until 10 hours and one hour intervals until 24 hours After a few seconds the time is saved to the memory of the air conditioner and the automatic start indicator appears...

Page 11: ...d dehumidification modes 2 Automatic start and shut off function Automatic start The automatic start function makes it possible to set a time after which the portable air conditioner will start automa...

Page 12: ...air filters are clean Insert a new set of batteries into the remote control Proceed according to the instructions in section Inserting and replacing batteries Install the portable air conditioner acco...

Page 13: ...r w d h 440 369 720 mm Weight 31 kg net Operating temperature cooling 18 32 C Operating temperature heating 10 25 C Recommended room area 30 41 m2 The declared noise emission level of the appliance is...