50Hz electrical loads.
OFF
Page 1: ...l carefully and pay particular attention to the IMPORTANT SAFETY INSTRUCTIONS on Pages 2 3 Remember that all power equipment can be dangerous if used improperly Also keep in mind that SAFETY requires...
Page 2: ...product and this document at any time without prior notice SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that foll...
Page 3: ...his generator is not for use in mobile equipment or marine applications WHEN TRANSPORTING OR REPAIRING EQUIPMENT Transport repair with petrol tank EMPTY or with petrol shutoff valve OFF Disconnect spa...
Page 4: ...an damage it and shorten its life Use generator only for intended uses Operate generator only on level surfaces DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT inser...
Page 5: ...nerator Running Time per time Total Running time Air Filter Fuel tank Engine cover Engine Switch Circuit breaker Switch between single phase and three phase Multifunctional display meter Power indicat...
Page 6: ...m of 85 octane DO NOT use petrol which contains Methanol DO NOT mix oil with petrol 2 Clean area around petrol fill cap remove cap 3 Add regular unleaded petrol to petrol tank Be careful not to overfi...
Page 7: ...decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain DO NOT hand...
Page 8: ...50Hz electrical loads OFF...
Page 9: ...ning 45A 10KVA The three phase in Grannitto Service Center Use a compatible three prong plug with this receptacle Figure 4 Connect a 3 wire cord set rated 220V at 30 AC Amps to the plug For Single pha...
Page 10: ...is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have...
Page 11: ...Maximum output Watts 12000 VA Continuous Wattage Capacity 10000 VA Power Factor 1 0 Rated Maximum Continuous AC Load Current At 220 Volts 45 Amps Phase 1 phase Rated Frequency 50 Hertz Petrol Tank Cap...
Page 12: ...se approved spark plug tester DO NOT check for spark with spark plug removed Generator Cleaning Use a damp cloth to wipe exterior surfaces clean STORAGE The generator should be started at least once e...
Page 13: ...rator circuit 1 Out of petrol 2 Petrol valve is in the Closed position 3 Low oil level 1 Out of petrol 2 Low oil level 3 Generator tipped at angle Load is too high Solution 1 Reset circuit breaker 2 C...
Page 14: ...portant emissions information and critical safety warnings Read Understand and Follow all warnings and instructions in this manual the engine manual and on the machine engine and attachments If you ha...