www.semtech.com
Page 13
ADVANCED COMMUNICATIONS & SENSING
USER GUIDE
SX8724SEVK
Evaluation Kit for SX8724S Data Acquisition System
ACS - Revision 1.0 May 2011
© Semtech Corp.
8.2
Power Supply Selection
Available supply voltages vs. selected power source is described below.
IMPORTANT NOTICE
- DO NEVER CONNECT VEXT JUMPER IF EXTERNAL VOLTAGE IS HIGHER THAN 5.5VDC.
- CONNECT ONLY ONE JUMPER ON THIS SELECTOR
The picture below shows the selector. User should place the jumper on the desired SX8724S supply voltage
value.
Figure 7. Power Supply Schematic
Figure 8. SX8724SEVK Power Supply Selector
1
2
J8
GND
Fe
rr
ite
F2
VBUS
1
D- 2
D+ 3
GND
5
SHL D 4
J6
H2959CT-ND
Ferrite
F1
10uF
C3
NC
C6
1uF
C7
100nF
C8
1uF
C4
100nF
C5
ON
Re d
470R
R3
SHDN
3
N
C
4
VS
S
2
VOUT
5
VI N
1
U3
MCP1802
27pF
C1
27pF
C2
VLDO
W3
W1
W2
VBUS
VBOARD
PGD/D+
PGC/D-
VEXT
USB
INTERFACES
VEXT
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
BOARD VOLTAGE SELECTOR
W4
Power jumper
Power LED
Enter here with an
external power supply
External voltage
5V from USB
Regulated 3.3V
Board voltage
Board Voltage Selectors