Instructions for Use
HEAD 10 Escape Set
K0² Regenerative Device for Short Term Use
IFU21082017 - HEAD 10 Issue_v2c
© Semmco LPS Ltd 2017
– This document is not to be copied or reproduced without the permission of Semmco LPS Ltd
STORAGE AND USAGE CONDITIONS
The device can be stored for up to 12 years (after a satisfactory inspection at
6 years and 9 years at Semmco LPS Ltd). Official regulations on inspection
must be observed. For units which are routinely carried, the following visual
checks must be carried out daily.
•
The carrying case must be free from damage.
•
The security tag must be in place and un-damaged.
•
The vacuum indicator must be blue.
If these conditions are not met the unit should not be used
and should be replaced with a new unit
RETURN CONDITIONS
The protective device contains potassium superoxide (K02) therefore
transportation hazard regulations apply when in transport. The devices can
only be transported by road, rail or air cargo and should be returned in their
original transportation packaging and marked with the appropriate hazard
identification label. When returning damaged or used devices they must be
sealed in a plastic bag prior to placing in the transportation packaging.
The devices can be returned for disposal or rework to the Reclamation Unit
at the address below:
Semmco LPS Ltd
9 Kestrel Way, Goldsworth Trading Estate
Woking
Surrey
GU21 3BA
England
ORDERING INFORMATION
Description
Part No.
HEAD 10 ESCAPE SET CARRY CASE
802.000.19
HEAD 10
–
Rework
on request
HEAD 10
–
6 & 9 year inspection
on request
HEAD 10
–
Training systems
on request
Semmco LPS Ltd
9 Kestrel Way, Goldsworth Trading Estate
Woking
Surrey GU21 3BA
UK
Tel: +44 (0) 1483 757200
Fax: +44 (0) 1483 740795
www.semmco.com
PRODUCT IDENTIFICATION
–
HEAD 10 CARRY CASE
KEY
1
HEAD 10 VAC PACK
2
VACUUM INDICATOR
3
CARRY CASE
4
DATE AND SERIAL NUMBER LABEL
5
SECURITY TAG
KEY
1
OVER PRESSURE VALVE FITTED TO BACK OF HOOD
2
PRESSURE RELIEF VALVE
3
OXYGEN STARTER
4
RESERVOIR BAG
5
OXYGEN GENERATOR
6
SUPPLY TUBE
7
MASK AND HARNESS
8
WARNING LED
9
HEAT SINK
10
FRONT PORT
11
VISOR
12
HOOD
TECHNICAL DATA
Intrinsic Safety Label
•
Inspiratory/expiratory resistance at 35L/min
<±4 mbar
•
Temperature Inhaled gas 35L/min
< 50°C
•
Breathing Bag Volume
≥
8 litre
•
CO² content (inhaled gas)
< 3 vol%
•
Operating time according to EN13794
10 minutes
•
Weight with case
(kg)
2.4 CC
•
Weight without case (kg)
1.5
•
Case dimensions (mm) approx
330 x 190 x 140
•
Temperature: Storage
-20 to +50°C
•
Temperature: In Use
-6 to +50°C
•
Max surface temp
< 100°C
EU DECLARATION OF CONFORMITY
Manufacturer: Semmco LPS Ltd
9 Kestrel Way Goldsworth Trading Estate
Woking Surrey GU21 3BA
Under the sole responsibility declares that the PPE described below
HEAD 10 Escape Set
–
CC 802.000.19
1.
Is in conformity with the PPE Regulation (EU) 2016/425 and with the relevant
requirements of the appropriate sections of the harmonized standards
EN13794:2002, EN145:1998 and DIN58652:2005-. for general specification and
performance and EN1146 for the hood, it is deemed to meet the basic safety and
health requirements (Annex 11) of the Regulation.
2.
Are identical to the PPE which is the subject of EU certification of conformity No.
CE690202 issued by:
BSI Group
Kitemark Court
Davy Avenue
Knowlhill
Milton Keynes
MK5 8PP
3.
Are subject to the procedures set out in PPE Regulation (EU) 2016/425 under the
supervision of the notified body SGS United Kingdom Ltd. NB0120
Signed:
Authorised Signatory
–
General Manager Semmco Group
On behalf of Semmco LPS Ltd
Issue: 02c
Dated: January 2021
Telephone: +44 (0)1483 757200 Fax: +44 (0)1483 740795
Email: [email protected] www.semmco.com