Instructions for Use
HEAD 10 Escape Set
K0² Regenerative Device for Short Term Use
IFU21082017 - HEAD 10 Issue_v2c
© Semmco LPS Ltd 2017
– This document is not to be copied or reproduced without the permission of Semmco LPS Ltd
CONTENTS
•
IMPORTANT NOTICE
•
INTENDED USE
•
PRECAUTIONS
•
PRIOR TO USE
•
OPENING DEVICE
•
DONNING DEVICE
•
USAGE PICTOGRAMS
•
USE
•
AFTER USE
•
STORAGE AND USAGE CONDITIONS
•
RETURN CONDITIONS
•
ORDERING INFORMATION
•
PRODUCT IDENTIFICATION
•
TECHNICAL DATA
•
EU DECLARATION
IMPORTANT NOTICE
1.
The equipment should only be used for the purposes specified in this
manual.
2.
All individuals involved in the use of the equipment must read and
understand the contents of this manual and have been trained by a
Semmco LPS Ltd certificated trainer.
3.
All individuals involved with the training of the end user or maintenance
of this equipment must be authorised and certificated by Semmco LPS
Ltd.
4.
The warranties made by Semmco LPS Ltd with the regard to this product
are void if the equipment is not used and serviced in accordance with the
instructions in this manual.
5.
The warranties and conditions of sale of Semmco LPS Ltd are not to be
altered by the above recommendations.
INTENDED USE
HEAD 10 ESCAPE SET is a short duration, oxygen breathing device, which is
intended for a single emergency use, in areas of:
•
smoke
•
toxic contamination and
•
oxygen deficiency
•
Potentially explosive atmospheres (when supplied in a carry case)
HEAD 10 is available in the following options;
HEAD 10 CC
–
Carry Case
The apparatus, described in these instuctions for use, has been designed and
tested in accordance with EN13794, EN145, EN1146 and DIN 58652-1
where applicable, to demonstrate compliance with the essential safety
requirements with PPE Regulation (EU) 2016/425. Intrinsic safety as per SIRA
certificate Sira 04Y2057X.
Type examination performance by: BSI Group, Kitemark Court, Davy
Avenue, Knowlhill, Milton Keynes MK5 8PP
(Notified Body Number 0086)
PRECAUTIONS
•
Due to the potential fire risk it is important to prevent the ingress of
flammable substances such as petrol, grease or solvents into the device
before and during operation.
•
If the device is damaged there is a risk that flammable substances may be
ignited if they come into contact with the oxygen producing chemical.
•
Do not remove the device from the case until the equipment is required
for use. Doing so may reduce the protection afforded by the device.
PRIOR TO USE
Check case to ensure:
•
The case is not damaged.
•
The security seal is still intact.
•
The unit is within the expiry date.
•
The vacuum pack is intact and the Indicator is not pink in colour.
•
The equipment should not be used if these conditions are
not met.
OPENING DEVICE
HEAD 10 CARRYING CASE
1.
Open carrying bag by pulling webbing tag.
2.
The lid will fall away to reveal vacuum pack. Go to 3 below.
3.
Pull firmly on the breathing protection device to remove from
vacuum pack. This action automatically activates the oxygen
generation into the breathing bag, commences the alarm self-test
procedure and removes the two red sealing bungs from the device. If
these remain attached remove manually.
DONNING HEAD 10
1.
Unfold the hood, place fingers inside neck seal, inhale and pull onto
head.
2.
Hold front port and adjust position of inner mask to ensure correct
fit, comfort and field of vision.
3.
Exhale into mask and commence normal breathing.
NOTE:
•
The action of removing the breathing device from the vacuum bag
automatically activates oxygen generation, the alarm self test and
removes the two red sealing bungs from the device. The LED and
alarm will sound for a few seconds to indicate it is functioning
correctly. In the unlikely event the alarm self check is not
activated, HEAD 10 remains safe to use however no reliance
should be placed on the alarm timer. The two red rubber bungs
are connected inside the bag via a red lanyard, if for any reason
the bungs stay attached to the device when it has been removed
from the bag they should be removed from the device manually
before donning starts.
•
Facial hair in the sealing area may cause leaks and can seriously
reduce the protection provided by the apparatus.
•
The correct positioning of the inner mask is essential to
provide a face seal and prevent ingress of atmospheric
contaminants.
•
Always follow training procedures. The hood must be
properly sealed before starting to use the equipment.
USAGE PICTOGRAMS
HEAD 10 ESCAPE SET CC
USE
•
Once activated and the correct function checked, the red LED
’s
and
audible warning will operate intermittently when two thirds duration
of the operating time has elapsed. This will change to the constant
mode when the stated duration is reached. This warning will continue
for a further period of approximately 5 minutes.
•
When the warning device activates the constant mode, HEAD 10 may
be ending and that the device may no longer be providing protection.
IMPORTANT NOTES FOR USERS
•
Immediately the device is donned and a seal obtained
activities should commence in a calm manner. Do not
rush.
•
Maintain a steady work rate to ensure regular breathing.
Rapid breathing uses more oxygen.
•
During use the starter and oxygen
generators will
increase in temperature and the air provided by this
device will be warm and dry and slight odours or tastes
may be detected. These are normal conditions and
indicate the device is functioning correctly.
AFTER USE
•
Remove the hood immediately in a safe area, or when the warning
device indicates oxygen production may have ceased.
•
The device can be returned to Semmco LPS Ltd for reclamation or
rework
, see section on ‘RETURN CONDITIONS’
.