508.366.1488 | www.semshred.com
10
After the unit has discharged, the media tray will be released automatically so that the now
erased media can be removed.
NEVER PULL ON THE MEDIA TRAY DOOR. This will damage the locking mechanism.
If the door ever fails to open, it will try again every five seconds. If it continues to fail or an
error is displayed, please contact the SEM service deptartment.
The magnetic field strength indicator is displayed in the upper middle portion of the screen.
This displays the actual measured strength of the magnetic field produced during the cycle
and grades the value PASS or FAIL. Shown above is a model EMP1000, where 1.53 Tesla is
results as a PASS.
The magnetic field strength is displayed in units of Tesla (flux density). If PASS is indicated,
the media can be removed, the next media to be erased can be inserted and the cycle
started again.
If FAIL is indicated then the current media should be run again. If FAIL is encountered too
many times or if an error is present, please contact the SEM service department.