Seltron RCD1 Premium Manual Download Page 11

 |  11

Instructions for use 

EN

OPERATION MODE SELECTION 

(RCD2 ONLY)

SETTING THE TEMP. FOR FROST PROTECTION

PARTY FUNCTION (RCD2 ONLY)

We can change the setting of the requested room temp. which is considered when the 

heating is on. When the heating is off, by pressing the button   or   recall the display 

of the set temp. 

If the button   or   is pressed and held for at least 2 seconds, 

the setting value will begin to flash. Now you can change it with buttons   and   . 

By pressing the button we confirm the setting. 

By the next press of the button return to the basic display.

For the frost protection to be active, the boiler or the heat generator must be 

turned on! Frost protection temp. setting is enabled only when heating is off 

and functions Party, Eco and Vacation are not active.

Party function enables to turn on heating according to the requested comfort tempera-

ture at any time. Function can be activated by pressing the button  .

Now we can change the requested comfort temperature with buttons   and  .

Change the setting while the value is flashing. By pressing the   or button, we move 

to time setting. Use buttons   and   to set time until when comfort heating should 

operate. Change the setting while the value is flashing. By the next press of the button 

 or return to the basic display.

When the Party function is on, we can check or change settings by pressing button   

or  .

Party function can be reactivated before expiration of time by pressing again the but-

ton   (RCD2 only).

Requested comfort or Party temp.

Time when Party function expires

Party function display

Summary of Contents for RCD1 Premium

Page 1: ...RCD Room unit EN EN...

Page 2: ......

Page 3: ...r frost protection 11 Party function RCD2 only 11 Holiday function RCD2 only 12 Eco function RCD2 only 12 Operation mode selection RCD2 only 12 One time domestic hot water warming function RCD2 only 1...

Page 4: ...4 3 1 2 Illuminated display 1 Button for increasing a setting or moving forwards 2 Light sensor 3 Button for reviewing data and entering settings 4 Button for reducing the setting or moving backwards...

Page 5: ...n for reviewing data and entering settings 4 Button for turning on off room heating 5 Button for reducing the setting or moving backwards 6 Button for turning on off the Party function Button for turn...

Page 6: ...lashing When the protective function is no longer present the symbol is lighted When we read the protective function in the notification list on the controller the symbol turns off Notification about...

Page 7: ...ecast sunny Weather forecast overcast Weather forecast cloudy Weather forecast rainfall Sound signalling of warnings and notifications is repeated at 20 00 if warnings or notifications are still prese...

Page 8: ...e Holiday function ends SYMBOLS FOR DISPLAYING DAY OF THE WEEK AND STATE OF TIME PROGRAMMES SYMBOLS FOR OPERATION MODE INDICATION The number by the symbol marks the first or the second time program ac...

Page 9: ...and displays the room temperature in addition to other infor mation about the microclimate in the room Use the button to browse through data How much and which information can we browse is determined...

Page 10: ...ssing the button or activate settings of the requested temperatures Actual requested temp is displayed Buttons and change the requested temp Change the setting while the value is flashing For setting...

Page 11: ...tting is enabled only when heating is off and functions Party Eco and Vacation are not active Party function enables to turn on heating according to the requested comfort tempera ture at any time Func...

Page 12: ...Requested saving or Eco temp Time when Eco function expires Eco function display Vacation function enables activation of heating according to the requested saving temp until a specific date at any ti...

Page 13: ...One time d h w warming function display The Fireplace function enables temporary shut down of room temp effect on room heating regulation This function is turned on when we make a fire in the fireplac...

Page 14: ...s P2 user settings parameters S1 service settings parameters By pressing the button for 2 seconds we enter the menu Move between groups with buttons and By pressing the button we enter the selected gr...

Page 15: ...ER SENSOR Measured and calculated temp for T7 sensor are displayed alternately t1 8 T8 CONTROLLER SENSOR Measured and calculated temp for T8 sensor are displayed alternately t1 9 T9 CONTROLLER SENSOR...

Page 16: ...play illumina tion The following settings are available 0 no display illumination 1 The display has maximum brightness when entering settings to the room unit After a delay display illumination is red...

Page 17: ...G WARNINGS AND MESSAGES This setting determines whether warnings and notifi cations are displayed 0 no display 1 warnings 2 warnings and notifications P1 10 BASIC DISPLAY This setting determines which...

Page 18: ...ine Setting range is identical to parameter P1 11 Factory setting is 0 no display P1 16 SIXTH DISPLAY IN THE INFO LINE This setting determines which information will be displayed sixth in the info lin...

Page 19: ...setting determines the correction of measured relative humidity in the room 10 10 0 S1 6 AIR PRESSURE SENSOR CALIBRATION This setting determines correction of measured air pressure 100 100 mb 0 S1 7 A...

Page 20: ...m possible setting of room temp 4 40 C 30 S1 13 TIME OF IGNORING ROOM TEMP RCD2 only Used with the fireplace function Operation of fire place function is described in the chapter Fireplace Function 1...

Page 21: ...GS LOCKING SETTINGS By locking keys we limit or disable unrequested settings or activation of functions Buttons are locked by pressing the button for 10 seconds and unlocked by pressing the button for...

Page 22: ...uilt in or the auxiliary sensor contains the fault Check type and connection of auxiliary sensor If the error is not fixed room unit should be sent to service Auxiliary sensor error Check type and con...

Page 23: ...1 P2 1 2 Room unit address is 2 During initial operation room unit address is set automati cally If one room unit is connected it acquires address 1 If an additional room unit is connected it acquires...

Page 24: ...r Yes Yes Air quality sensor No Yes Air pressure sensor Yes Yes Power communication line bus communication line bus Maximum use 0 02 W 0 02 W Level of protection IP 30 acc to EN 60529 IP 30 acc to EN...

Page 25: ...ot be discarded as household waste It needs to be taken to a collection point for waste electrical and electronic equipment WEEE Suitable disposal of this product prevent negative effect on the enviro...

Page 26: ...26 Instructions for use EN MOUNTING AND ELECTRICAL CONNECTION 1 2 3...

Page 27: ...27 Instructions for use EN MOUNTING AND ELECTRICAL CONNECTION 0 25 mm2 0 75 mm2 0 25 mm2 0 5 mm2 0 25 mm 2 0 5 mm 2 WDC WXD KXD CMP25 2 4 5 6 7...

Page 28: ...28 EN NOTES...

Page 29: ...29 EN NOTES...

Page 30: ...30 EN NOTES...

Page 31: ......

Page 32: ...serve the right to errors changes and improvements without prior notice Seltron d o o Tr a ka cesta 85 A SL 2000 Maribor Slovenia T 386 0 2 671 96 00 F 386 0 2 671 96 66 info seltron si www seltron eu...

Reviews: