ENG
SETTING MANUAL
18
Basic parameters P1
Basic parameters P1 are used for the thermostat user settings. To change the
selected parameter, hold key for approximately 5 seconds. Parameter
starts to flash. Press key or to set the parameter value. To store the
setted value, again hold key for approximately 5 seconds. Group P1
contains the following parameters;
(factory setting)
:
- [P1.1] night temperature (6 °C ÷ 26 °C);
(17 °C)
- [P1.2] temperature reduction in ECO mode
(0 °C ÷ -9 °C);
(-3 °C)
- [P1.3] frost protection temperature (0 °C ÷ 20 °C);
(6 °C)
- [P1.4] temperature sensor calibration (-2 °C ÷ 2 °C);
(0 °C)
- [P1.5] auxiliary temperature sensor calibration
(-2 °C ÷ 2 °C);
(0 °C)
- [P1.6] display of measured temperatures (1 - room, 2 - outdoor,
3 - room and outdoor alternating, 4 - requested temp.);
(1)
- [P1.7] beeper mode (
- - -
silent,
1
- by typing,
2
- by timer
switchover,
3
- by typing and timer switchover);
(1)
- [P1.8] display of controlled devices (1 - visible, 2 - hidden);
(1)
- [P1.9] temperature increase in PARTY mode
(0 °C ÷ -9 °C);
(0 °C)
- [P1.10] temperature display by ESC command in normal display (see table):
Parameter
value
WDC
CMP25-2
D10, D20 / CMP25
---
Auxilliary sensor
DD2+
Auxilliary sensor DD2+
Auxilliary sensor DD2+
1
T1
Room temperature
Outdoor temperature AF
2 T2
Not used.
Room temperature RF
3 T3
Outdoor
temperature
Stand-pipe
VF
4 T4
Stand-pipe
Return-pipe
RLF
Summary of Contents for DD2+
Page 1: ...DD2 ITA ENG FRE Thermostat d ambiance Termostato ambiente Room unit Raumeinheit DEU ...
Page 2: ......
Page 4: ......
Page 5: ...ENG Room unit DD2 User manual Setting manual Installation maual ...
Page 6: ......
Page 32: ......
Page 33: ...DEU Raumeinheit DD2 Bedienungsanleitungen Betriebsanleitungen Montageanleitungen ...
Page 59: ...ITA Termostato ambiente DD2 Istruzioni per l uso Istruzioni per il montaggio ...
Page 60: ......
Page 86: ......
Page 87: ...FRE Thermostat d ambiance DD2 Notice d emploi Instructions de service Instructions de montage ...
Page 114: ...114 DD2 Promatic D10 Promatic D20 Promatic D10 D20 ...
Page 115: ...115 DD2 Promatic CMP25 Promatic CMP25 2 CMP25 CMP25 2 ...
Page 116: ...116 DD2 Promatic WDC10B WDC10 WDC20 Promatic WDC10B Promatic WDC10 Promatic WDC20 ...
Page 117: ...NOTES 117 Notes ...
Page 118: ...NOTES 118 Notes ...
Page 119: ......
Page 120: ...J5060384 V1 2r0 0 1 MC0 6 0 1 8 7 ...