SellEton Scales SL-924 User Manual Download Page 3

1

SAFETY PRECAUTIONS 

For safe operation of the weighing scale, please follow these 
instructions:

Calibration inspection and maintenance of the scale are prohibited by
non-professional staff

Please ensure that the scale hangs securely

The scale is a piece of static sensitive equipment; Please cut off power during
electrical connections

Touching the internal components by hand is prohibited

DO NOT exceed the rated load limit of the unit

DO NOT hang on the unit

DO NOT use this product if any of the components are cracked

DO NOT use for purposes other then weight taking

To avoid damaging the battery do not keep charger plugged in once the battery is
fully charged

Make sure the weight is not over the Max capacity as it could damage the load cell
inside

● Material that has a static electric charge could influence the weighing. Discharge

the static electricity of the samples, if possible. Another solution to the problem is
to wipe the scale with an anti-static agent

Please take anti-static prevention measures

Any accumulated charge on the body of the human operator should be discharged first 

before opening the protective container with ESDS devices inside. The discharge can 
be accomplished by: 

Putting a hand on a grounded surface or, ideally, by wearing a grounded Anti-static
Wrist Strap and an Anti-static Mat

PREPARATION & SET UP

Plug into a wall outlet to avoid interference with other wirings

Turn on the scale while there is no load

Calibration may be required before weighing when the scale is initially installed or
moved from a location

Summary of Contents for SL-924

Page 1: ...www selletonscales com SL 924 CRANE SCALE USER S MANUAL SL 924A SL 924B Series...

Page 2: ...cautions 1 Preparations and Set Up 1 Features 2 Specifications 3 Power Supply 4 Displays 5 Display and Key Descriptions 6 Operating Instructions 7 98 Calibration 9 10 Scale Parameter Settings 11 Troub...

Page 3: ...re the weight is not over the Max capacity as it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the sampl...

Page 4: ...ght Remote controller can capture peak weight at a distance of up to 100 feet 30m Wireless remote control has Hold function Low battery reminder Automatic power off power saving mode Technical Paramet...

Page 5: ...TERIOR DIMENSIONS A B C D E 5 88 8 50 5 75 2 91 15 16 17 13 HOOK DIMENSIONS A B C D E F G H I J K UP TO 2 000 LBS 2 55 0 60 1 35 2 65 3 25 0 90 0 90 2 92 0 96 3 15 4 92 OVER 2 000 LBS 2 55 0 60 1 35 2...

Page 6: ...ge resulted from left leakage of battery Once charged the battery should last for 45 hours An AC adapter should be provided with your scale Please use only the AC adapter provided to prevent damage to...

Page 7: ...5 SL 924A LED SL 924B LCD...

Page 8: ...in Gross weighing mode Battery Flashes red low battery Solid red charging Power Up Arrow Key Right Arrow Key Return Enter Enter 2nd Mode REMOTE KEY DESCRIPTIONS KEY Weighing Mode 2nd Mode Data Input...

Page 9: ...ss the 2nd key followed by the Zero key to switch between units Tare Function The Tare function is used when you only wish to see the current change in weight not the entire amount of weight that is o...

Page 10: ...nt to accumulate have been added to the scale Note Incase of a mistake Press DEL to clear the last accumulation data the display should show deL if not it will display nodeL Press F1 to total your wei...

Page 11: ...lbs FS 01 3 000 lb 0 5 lb 300 lbs 10 The display should show CALon Press HOLD to enter calibration mode or press to exit calibration mode 11 If calibration mode is entered then it should display LoAd0...

Page 12: ...ntrols the relationship to the weight in direct proportion 3 Use the arrow keys to modify the parameters then press HOLD to confirm 4 The display should now show EnD press HOLD to confirm 5 Note after...

Page 13: ...ically if no change within 90 min 10 Power Saving Mode idle mode idl 0 turn off power saving setting 10 turn off display if no change within 10 minutes 30 turn off display if no change within 30 minut...

Page 14: ...splay and Instructions Error Reason Solution Err6 Exceed zero range Check the crane load U 628 Battery Power uuuuu Overload nnnnn Lower than the minimum value Reduce the weight 2nd 2nd mode weit foe c...