IF YOU'RE USING A STEEL PLATFORM:

You will need to weld each mounting block to the corner of the platform. Only weld on the outside of

the mounting block & ensure that all blocks are positioned in the same way, with the feet of the load

cell located in the corner of the platform (not facing inside the platform).

Picture below demonstrates the correct installation format.

WARNING:

Do not weld the mounting blocks

to the platform with the load cell

attached to it, it will damage the

load cells.

SL-720 

INSTALLATION MANUAL - WEIGHING KIT

Summary of Contents for SL-720

Page 1: ...ce platform not included with the kit This weighing kit is mostly used for floor scale livestock scale applications or to turn any object platform into a scale with Maximum capacity of 10 000 lbs You...

Page 2: ...g block x 4 load cell Mounting blocks typically welded to steel structures or bolted to wood x 8 Hexagon bolts x 8 washers x 8 lock washers x 1 Junction Box Plastic or Stainless steel x 1 Quick Connec...

Page 3: ...be drilled on every corner Each hole should be drilled as close to its respective edge as possible You need to purchase longer bolts for thicker platforms Measure the mounting block load cell along w...

Page 4: ...the mounting block ensure that all blocks are positioned in the same way with the feet of the load cell located in the corner of the platform not facing inside the platform Picture below demonstrates...

Page 5: ...refer to the diagram below for the indicator cable load cell wiring SL 720 INSTALLATION MANUAL WEIGHING KIT CAPACITY ACCURACY CHOICES 1000 lb Capacity x 2 lb Accuracy 2500 lb Capacity x 5 lb Accuracy...

Page 6: ...ow C03 10 Press PRINT to access the C3 channel The display should show C3 11 Press ZERO to cycle through the values until the desired graduation appears The C3 channel adjusts the divisions on the sca...

Page 7: ...n weight Single Point Calibration 20 Press PRINT to continue The display will now show C06 21 Press PRINT to access the C06 channel The display will show C6 0 22 The C6 channel is used to calibrate th...

Page 8: ...3 Check load cell input and output resistance 4 See Q A section 1 Calibration is no good 2 Wrong connection with load cell 3 Load cell has quality problem During calibration weight is not used or the...