Demand Start Adjust LED (5) (green) ON
It is sometimes necessary to adjust the demand start sensitivity to overcome
what is called “Phantom Loads”. A phantom load is a load that tricks the
inverter into thinking it should be ON instead of in SLEEP mode.
The wiring of a house or a portable stereo system in standby are good
examples of a phantom load. These loads serve no purpose but yet can
increase battery drain by bringing the inverter ON. Hold the Mode button (7)
down until LED (5) comes ON, (approximately 1 second) indicating you are
ready to adjust this setting. The LD700-24 will leave the factory with a
setting of 4 watts. Now press the Mode button (7) until the desired value is
sought. LEDs (1) – (4) will return to Status after 20 seconds.
Demand Start
Watts
LED 1
LED 2
LED 3
LED 4
4 Watts
5 Watts
6 Watts
7 Watts
Slow Flash
Medium Flash
Fast Flash
ON
ON
ON
ON
8 Watts
9 Watts
10 Watts
11 Watts
Slow Flash
Medium Flash
Fast Flash
ON
ON
ON
ON
12 Watts
13 Watts
14 Watts
15 Watts
Slow Flash
Medium Flash
Fast Flash
ON
ON
ON
ON
16 Watts
Continuous
ON
ON
ON
ON
ON
After “continuous”, the next button press “rolls back” the demand start
setting to 4 Watts