LD600-12 Manual 

Selectronic Australia

 

 

LED (2) 

AC Overload should normally remain OFF. If the inverter shuts 

down due to too much AC load being drawn from it then LED (2) will come 
ON. The LD600-12 will remain in this condition for 1 minute after the AC 
load has been decreased to a safe level. LED (2) will flash if the inverter 
shuts down due to “time to shutdown”. 

 

If the inverter remains in this condition after one minute, switch (12) 
should be turned OFF and then back ON. 

LED (3) 

DC Volts Low / High

 should normally remain OFF. If the inverter 

shuts down because the battery volts are too high then this LED (3) will 
come ON. It will remain ON until normal battery volts are restored. 

 

If the inverter shuts down due to not enough battery volts, then LED (3) 
will flash. 

 

LED (3) will continue to flash until the battery volts have risen 
sufficiently. In this case, charge the battery by starting the vehicle or 
using a battery charger. 

 
The low voltage point that the inverter will cut out is adjustable to suit your 
particular battery, see page 10 for details of this adjustment. 
 

LED (4) 

Temperature Overload

 should normally remain OFF. If the inverter 

shuts down due to the heatsink getting too hot, then this LED (4) will come 
ON. If the transformer is too hot then LED (4) will FLASH. The LED will 
remain ON or FLASHING until the temperature has lowered to a safe level; 
the inverter will then come back ON. 

 

If this LED (4) is coming on regularly, either reduce the amount of load 
on the inverter or try to move the inverter to a cooler location. 

LD600-12 Manual 

Selectronic Australia

 

Demand Start Adjust LED (5) (green) ON 

It is sometimes necessary to adjust the demand start sensitivity to overcome 
what is called “Phantom Loads”. A phantom load is a load that  tricks the 
inverter into thinking it should be ON instead of in SLEEP mode. 

The wiring of a house or a portable stereo system in standby are good 
examples of a phantom load. These loads serve no purpose but yet can 
increase battery drain by bringing the inverter ON. Hold the Mode button (7) 
down until LED (5) comes ON, (approximately 1 second) indicating you are 
ready to adjust this setting. The LD600-12 will leave the factory with a 
setting of 4 watts. Now press the Mode button (7) until the desired value is 
sought. LEDs (1) – (4) will return to Status after 20 seconds. 
 

Demand Start 
Watts 

LED 1 

LED 2 

LED 3 

LED 4 

4 Watts 
5 Watts 
6 Watts 
7 Watts 

 
 
 
 

 
 
 
 

 
Slow Flash 
Medium Flash 
Fast Flash 

ON 
ON 
ON 
ON 

8 Watts 
9 Watts 
10 Watts 
11 Watts 

 
 
 
 

 
Slow Flash 
Medium Flash 
Fast Flash  

ON 
ON 
ON 
ON 

 

12 Watts 
13 Watts 
14 Watts 
15 Watts 

 
Slow Flash 
Medium Flash 
Fast Flash  

ON 
ON 
ON 
ON  

 

 

16 Watts 
Continuous 

ON 
ON 

 
ON 

 
ON 

 
ON 

 
After “continuous”, the next button press “rolls back” the demand start 
setting to 4 Watts 

Summary of Contents for LD600-12

Page 1: ...erter Services Reid Technology 13 Thirteenth Ave Unit D 15 17 Saturn Place Sawtell North Harbour NSW Auckland 1330 2452 New Zealand Ph 02 66581733 Ph 9 489 8100 Fax 9 489 8585 psands reidtechnology co nz Suite 5 20 Fletcher Road Mooroolbark Victoria 3138 Australia Phone 61 3 9727 6600 Fax 61 3 9727 6601 Web www selectronic com au Email sales selectronic com au CS0135 Rev 04 Part No 003620 LD600 12...

Page 2: ...c Service Network Back Cover Legend for Symbols Warnings and electrician s notes Hints and Pointers Examples LD600 12 Manual Selectronic Australia 17 Miscellaneous Specifications Reverse Polarity Protection Output Voltage Accuracy 0 350 watts Output Frequency Peak Efficiency Total Harmonic Distortion Memory Retention Operating Temperature Range Transformer Type Cooling Method Power Point Chassis M...

Page 3: ...ctronic Australia 1 Introduction Thank you for choosing to purchase the Selectronic LD600 12 TRUE SINE WAVE inverter Many hours of Research and Development have gone into the LD600 12 to ensure this inverter provides you with many years of reliable service Warranty Card It is imperative that you complete your warranty card NOW Your LD600 12 is covered by a TWO year warranty this warranty is in add...

Page 4: ...ear the cost of parts and labour to repair any faults found within the terms and period of this warranty Faulty product or parts must be returned to Melbourne Australia at the owner s expense for claim under warranty No allowance is made for the cost of labour or traveling time required to disconnect or reinstall faulty parts Cost of freight to return parts to the customer will be paid by the manu...

Page 5: ...ll loads will still bring the inverter ON when required Inverter shuts down during the middle of the day and comes back ON late in the afternoon This is more than likely caused by high battery volts during peak charging times from Solar Panels Battery volts should never exceed 17 volts If this is the case have your Solar Regulator checked LD600 12 Manual Selectronic Australia 3 Portable Use By usi...

Page 6: ...n series add the voltage of each battery The capacity will equal the capacity of the smallest battery 2 x 6 Volt 150 Ah batteries connected in series would have a total capacity of 12 Volts 150 Ah LD600 12 Manual Selectronic Australia 13 Radio Frequency Interference Radio Frequency Interference RFI can be a problem for owners of inverters RFI in a domestic situation may produce noise or interferen...

Page 7: ...n parallel add the capacities together the voltage will remain the same as each batteries voltage 2 x 12 Volt 150 Ah batteries connected in parallel would have a capacity of 12 Volts 300 Ah Only use identical batteries when joining batteries together How long will my battery last To work out how long your battery will last follow this basic guide This guide presumes commencing with a fully charged...

Page 8: ...or any obstructions to the black cooling heatsink at the rear of the inverter The heatsink must be cleared of any accumulated foreign matter that may have lodged itself between the fins since the last maintenance check e g insect nests Also verify that airflow around the inverter has not become restricted Batteries 1 Every week carry out a thorough visual inspection of all battery wiring taking pa...

Page 9: ... front panel to indicate a number of parameters and allow adjustment of some of these parameters LED 5 tells you what LED 1 4 is displaying as indicated on the front panel of the LD600 12 Pressing Mode Button 7 will change the information being displayed STATUS indicators LED 5 green flashing When power is first applied LED 1 should flash When LED 5 green is OFF this indicates the LED 1 4 is showi...

Page 10: ...will FLASH The LED will remain ON or FLASHING until the temperature has lowered to a safe level the inverter will then come back ON If this LED 4 is coming on regularly either reduce the amount of load on the inverter or try to move the inverter to a cooler location LD600 12 Manual Selectronic Australia 9 Demand Start Adjust LED 5 green ON It is sometimes necessary to adjust the demand start sensi...

Reviews: