Selectronic 2506.192 Installation Instructions Manual Download Page 1

(In Toronto Area only: 1-905-3061093)

To learn more about American Standard Faucets visit our website at: 

www.us.amstd.com 

or U.S.

customer's e-mail us at: 

[email protected]

For Parts, Service, Warranty or other Assistance, 
please call

 

1-800-442-1902 (In Canada: 1-800-387-0369)

NOTE TO INSTALLER: Please give this manual to the customer after installation.

(In Toronto Area only: 1-905-3061093)

Installation Instr

uctions

In

s

ta

ll

a

ti

o

n

 I

n

s

tr

u

c

ti

o

n

s

© 2007 American Standard

Certified to comply with ASME A112.18.1M

M965274

2506.192, 2506.195

SELECTRONIC®

Hard-Wired AC Powered Moments

Lavatory Proximity Faucet

PRODUCT NUMBERS

Product No.'s & Options
Specifications
How to Install
Electrical Hook-up
Maintenance
FAQ,s
Replacement Parts

1
2
2-3
4-5
6-7
8
9

Summary of Contents for 2506.192

Page 1: ...ER Please give this manual to the customer after installation In Toronto Area only 1 905 3061093 I n s t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s 2007 American Standard Certified to comply with ASME A112 18 1M M965274 2506 192 2506 195 SELECTRONIC Hard Wired AC Powered Moments Lavatory Proximity Faucet PRODUCT NUMBERS Product No s Options Specifications...

Page 2: ...MBER 2506 192 with cast spout 1 5 GPM vandal resistant aerator 2506 195 with cast spout 0 5 GPM vandal resistant aerator OPTIONAL Mixing Valve 605XTMV Thermostatic mixing valve flex hoses 3 8 compression 20 hose length M965274 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 6 5 In Toronto Area only 1 905 3061093 To learn more about American Standard Faucets visit our w...

Page 3: ... checks and flexible stainless steel 15 reach inlet hose for spout connection 159mm 6 1 4 126mm 5 154mm 6 1 16 FINISHED WALL Fig 1a Fig 1b 1 4 6 5 3 2 INSTALL SPOUT ASSEMBLY Fig 1 CAUTION Turn off hot and cold water supplies before beginning 1 1 Insert WIRES 1 FLEX HOSE 2 and SPOUT SHANK 3 through center hole of mounting surface Fig 1a 2 Assemble C WASHER 4 STAR WASHER 5 and LOCKNUT 6 onto threads...

Page 4: ...TING HOLES SUPPLIES WASTE ENCLOSURE MOUNTING HOLES LAVATORY RIM OR MOUNTING SURFACE 3 NOTE If using Mixing Valve optional See Sheet M968808 for installation instructions MOUNT ENCLOSURE Fig 2 2 1 Connect SUPPLY NUT 1 from spout assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight connection Fig 3 NOTE If using the optional Mixing Valve See Sheet M968808 for...

Page 5: ...NNECTOR 11 into available CIRCUIT BOARD RECEPTORS 10 slots Fig 1e 8 Connect wires from SENSOR to SOLENOID VALVE 6 Red to Black to Fig 1d 9 Replace ENCLOSURE COVER 1 Tighten cover screws firmly 10 Contractor to supply ELECTRICAL BOX 12 and connection to ENCLOSURE 5 Mount POWER SUPPLY 13 into ELECTRICAL BOX 12 Connect White and Black power connections to POWER SUPPLY CABLE 14 Fig 1f 11 Connect the E...

Page 6: ...Unit 2 approximately 4 from connector Fig 3 Push SPLIT PLUG 7 into GROMMET 8 to seal 7 Insert connector of 10 ft EXTENSION into lower receptor as shown in fig 3 on CIRCUIT BOARD 6 of Unit 2 8 Feed gray sensor wire 9 from Unit 2 through upper U GROMMET 10 of Unit 2 ENCLOSURE 4 from connector Fig 3 Insert wire into SPLIT PLUG 7 Push SPLIT PLUG 7 into GROMMET 8 to seal Fig 3a 9 Insert GROMMET 2 back ...

Page 7: ...TROL LED 2 is blinking slowly place your hand 1 2 in 30 50mm in front of the sensor Fig 2a 3 When the LED stops blinking and stays ON move your hand to the desired position and hold in place until the LED begins to blink again Fig 2a 4 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set HOW TO CHANGE SEN...

Page 8: ...CLOSURE COVER 2 Close SUPPLY STOP 5 with 4mm Hex wrench Note Keep water flowing out of faucet while shutting off 3 Pull off Red 1 and Black 2 CONNECTORS from SOLENOID VALVE 3 4 Unthread STRAINER 4 using a 7 16 socket 5 Pull out the STRAINER 4 and clean with an old toothbrush Rinse thoroughly with water 6 Install the STRAINER 4 back in its place and tighten with a 7 16 socket Caution do not over ti...

Page 9: ...ow out of faucet when I m in the sensor range A Check sensor If sensor blinks 2 times interrupted by pause replace battery or call 1800 442 1902 Q Why does the faucet operate the opposite of expected Turns On when not in sensor range but turns off when in sensor range A Sensor wires to solenoid are reversed Black to Red to is correct Q What is the normal operating pressure range A Faucet will oper...