Testing the Unit: (See figure 1A)

 

Ø

  Turn the TIME dial clockwise on to the minimum (-) while also turning the LUX dial 

clockwise to the maximum (sun).

 

Ø

  Switch on the power; the sensor and its connected lamp will have no signal at the beginning. 

After Warm-up 30sec, the sensor will start to work.    If the sensor receives a signal within its 

radius, the lamp will turn on. When there is no signal to activate the lamp then it will turn off 

within 10sec

±

3sec.   

Ø

  Turn the LUX dial anti-clockwise on the minimum (10S). If the ambient light is more than 

3LUX,  the  sensor  would  stay  off  and  the  lamp  will  not  turn  off  also.    If  you  cover  the 

detection  window  with  an  opaque  object  (towel,  dark  cloth  etc),  the  sensor  will  work.   

When there is no signal within the radius of the unit then the sensor should turn itself off 

within 10sec

±

3sec. 

 

 

 

 

 

 

 

 

Note:  when  testing  in  daylight,  please  turn  LUX  dial  to  the        (SUN)  position, 

otherwise the sensor lamp may not work. If the lamp is more than 60W, the distance 

between lamp and sensor should be 60cm at the least. 

Problem Solving: 

Ø

 

If the load does not work: 

a. Please check if the connection of power source and load is correct. 

b. Please check if the load is good. 

c. Please check if the settings of working light correspond to ambient light. 

Ø

 

If the sensitivity is poor: 

a. Please check if there is any hindrance in front of the detection window which may 

affect the signal being received. 

b. Please check if the ambient temperature is too high or too low. 

c. Please check if the induction signal source is in the detection field. 

d.  Please  check  if  the  installation  height  corresponds  to  the  height  required  in  this 

instruction manual dependant on the wattage used. 

e. Please check if the moving orientation is correct and no loose parts are showing 

which may affect the sensor. 

Ø

 

The sensor cannot shut off the load automatically: 

a. Please check if there is continual signal in the detection field. 

b. Please check if the time delay is set to the maximum position 

c. Please check if the power / wattage corresponds to this instruction manual. 

INSTALLATION ADVICE:

 

As the detector responds to changes in temperature, avoid the following situations: 

Ø

 

Avoid  pointing  the  detector  towards  objects  with  highly  reflective surfaces,  such  as 

mirrors, reflective glass, windows etc. 

Ø

 

Avoid  mounting  the  detector  near  heat  sources,  such  as  central  heating,  heating 

vents, air conditioning units and artificial heat lamps etc. 

Ø

 

Avoid  pointing  the  detector  or  locating  the  detectors  in  places  where  objects  or 

household pets may continuously move. 

Ø

 

If in doubt always consult a qualified electrician before installation. 

 

 