background image

Page 4

3. Maintenance

Cartridge Replacement Schedule

1.

When the line pressure downstream of the filter

housing drops to 30 psi or below during system

operation, the cartridge(s) needs to be replaced.

Occasional dips below 30 psi and back are normal.

2.

For system backplate label for ordering informa-

tion for cartridge replacements.

3.

See below for Cartridge Changing Instructions.

4. Cartridge Changing Instructions

Step #1

Shut off inlet valve

. Push “Red” pressure relief button

located

at left end of SMF filter system to relieve pressure until no more

water comes out. Grasp filter cartridge, turn counter-clockwise 1/4

turn (when viewed from bottom) and pull downward about 1 1/2” to

remove the filter cartridge. Properly dispose of old cartridge.

Step #2

Remove and discard the “Red” sanitary cap from the top of the new

cartridge. Be sure to apply sufficient lubrication (supplied) to the

O-Rings. Align ear on cartridge with notch in filter head and push

upwards to insert. Be sure to push cartridge all the way in! Turn car-

tridge clockwise (when viewed from bottom) until a definite stop is felt

and cartridge is sealed. Hand tight is sufficient. Turn on inlet valve

Flush for one minute.

It is recommended that the cartridge be changed at least yearly, when

pressure drops significantly, or when bad tastes and/or odors return.

See page 1 or system backplate label for proper replacement cartridge

part number.

5

5

6

Lubricate O-Rings

Summary of Contents for SMF Series

Page 1: ...em Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Proud Member of UM SMF IC Rev 9 12 07 Installation and Operating Instructions covering all SMF water filtration systems including but not limited to SMF IC600 SMF IC600 SMF IC620 SMF IC600 3 SMF IC620 IC620 2 IC620 3 SMF IM600 IM614 SMF IcePRO SMF CoffeePRO SMF Espresso 7500 SMF Espresso 120...

Page 2: ...1 Installation Precautions 2 Installation Page 2 ...

Page 3: ...are being used See Item Teeing the tubing should be done appropri ately for example 1 2 x 1 2 x 1 2 This is only to be done at equipment location if line is to be used for other equipment Initializing Water Filter 4 Check to be sure that the cartridge is properly installed Do this by turning the cartridge counter clockwise when looking at the bottom of the cartridge and then back clockwise until t...

Page 4: ...se 1 4 turn when viewed from bottom and pull downward about 1 1 2 to remove the filter cartridge Properly dispose of old cartridge Step 2 Remove and discard the Red sanitary cap from the top of the new cartridge Be sure to apply sufficient lubrication supplied to the O Rings Align ear on cartridge with notch in filter head and push upwards to insert Be sure to push cartridge all the way in Turn ca...

Page 5: ...to remove Gently remove the leaking fitting by pulling straight out Apply additional lubricant supplied to the O ring and re insert the fitting by gently pushing all the way in until the shoulder on the fitting contacts the filter head Examine the retaining clip for any cracks from removal and re insert by pushing straight down until it is all the way in If retaining clip is cracked or stretched i...

Page 6: ...ridge by following the procedures outlined in Step 1 of the Cartridge Changing Instructions on Page 5 and installing the Bypass Plug in its place When installing the Bypass Plug it is necessary to properly lubricate the O Ring using the lubricant provided Install the plug the same as a replacement cartridge by fol lowing the procedures outlined in Step 2 of the Cartridge Changing Instructions on P...