![Selecto MF620C Conversion Instructions Download Page 2](http://html.mh-extra.com/html/selecto/mf620c/mf620c_conversion-instructions_1236844002.webp)
MF620C to SMF IC620 Conversion Instructions
Page 2
5
7
6
8
Selecto, Inc.• 3980 Lakefield Court • Suwanee, GA 30024 USA • 800-635-4017 • 678-475-0799
a.) Align the “ears” of the plug and cartridge with slots in
the SMF Adapters and insert by pushing upwards.
b.) Turn the plug and cartridge 1/8 turn “clockwise” , when
viewed from the bottom, until the “ears” are fully enaged
into the slots of the SMF Adapters.
c.) In problematic water areas, it may be desirable to use
optional pre-filter #108-231 in place of the bypass plug.
a.
b.
a.) Turn water supply back “On”.
b.) Leave 3-way valve handle “down” to drain until all air is
purged from the system and only water comes out.
c.) Turn 3-way valve handle “Up” to direct water to equip-
ment. Check for leaks.
Apply lubricant (supplied) to O-Rings of plug and cartridge.
Apply new label to backplate and new cartridge identification
labels to left and right hand side filter heads.
b.
a.
c.
c.