MANUAL DE INSTRUCCIONES CODIGO 80115 REV E FEB 2017 (Sujetas a modi
fi
caciones sin previo aviso)
Pag.: 16
J
.P. SELECTA s.a.u.
Ctra. NII Km 585.1 Abrera 08630 (Barcelona) España
Tel 34 937 700 877 Fax 34 937 702 362
e-mail: selecta @jpselecta.es - website: http://www.jpselecta.es
7 Installation
7.1 Placement
Place the equipment near of a socket on a levelled
fl
oor (see «Power supply connection
section) keeping in mind the follwing:
- When placing the equipment make sure that the pipes are not damaged.
- Once in position, use the provided spanner to adjust the feet so that the
equipment is leveled.
- Do not place it in direct sunlight or near to a heating source.
- Do not place the equipment in wet places or where may get water splashes.
- The room where is installed the equipment has to be at a distance of, at
least, 7 squared metres because, in case of refrigerant gas leakages, would
not exist risk of
fl
ammable mixtures production.
- Before starting up, remove all the transport blocking.
DO NOT INSTALL THIS EQUIPMENT IN EXPLOSIVE ATMOSPHERES OR IN PLACES
WHERE THERE ARE SOLVENTS OR OTHER PRODUCTS WHICH MAY PRODUCE EX-
PLOSIVE OR FLAMMABLE GAS.
7.2 Power Supply Connection
Make sure that the voltage given by the socket is the indicated on the feature label
attached on the rear part.
The plug socket must be protected by a 10A to 16A fuse or circuit breaker.
Do not use the equipment unless it is correctly earthed.
If you replace the plug, keep in mind the following:
Blue wire:
Neutral
Brown wire:
Phase
Yellow/green wire:
Ground
6.3 Panel de mandos
1. ON / OFF key
2. SuperFrost key
3. Brightness Symbol
4. SuperFrost Symbol
5. Temperature indicator
6. Up / Down adjustment key
7. Alarm key
8. Block symbol for accidental handling
9. Menu symbol
10. Alarm symbol