Please read these instructions carefully and store in a safe
place for future reference.
Select
As part of the Insect-O-Cutor
®
brand of insect control
products, the Select range is an effective and flexible range of
professional flykillers which utilise highly effective Synergetic
®
UV tubes. Constructed from coated mild steel or robust
stainless steel, the Select range can be wall mounted or ceiling
suspended.
Contents of package
- 1 x Insect-O-Cutor flykiller
- 1 x Mains cable (Type X)
- 2 x Wall mounting screws and wall plugs
- 2 x Suspension hooks
- 2 x Suspension chains
- 1 x Backplate
- 1 x High powered UV tube (SE22 - Fitted)
or
- 2 x High powered UV tubes (SE44 - Fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
The Select range utilise high powered ultra violet tubes to
attract flying insects and then electrocutes them on a killing
grid, before collecting them in a removable catch tray.
WARNING
The Select range is not to be used by persons with reduced
physical, sensory or mental capabilities, or lack of experience
and training, unless they have been given instruction.
Children should be supervised to ensure they do not play with
the appliance.
If the mains cable is damaged it must be replaced by a
specialist mains cable available from Pelsis Ltd or your supplier.
The Select range must only be used in areas which are free of
dust and any possible explosive vapour mixture, are suitable
for indoor use only and are not suitable for use in barns, stables
and similar locations.
POSITIONING AND GUIDANCE FOR USE
The Select range should ideally be fixed around two meters
above the ground, preferably in the darkest place within the
area to be protected. Do not position the unit close to
windows, skylights or other sources of light, or where it may be
obscured by furniture, doors or other obstacles.
The Select range should ideally be in operation for 24 hours a
day, ensuring your premises are kept free of flying insects.
Insects are most attracted to the Select range units at night
when there is no competition from daylight or other light
sources.
GUARANTEE
The Select range has a five year guarantee and if maintained
as recommended in these instructions should continue to work
for many years*. Use of non-approved consumables may
invalidate the guarantee.
*Excludes tubes and starters. Does not cover breakdown due to misuse, incorrect operation
or use in an incorrect application.
INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE
PERSONNEL ONLY.
Before installation, first remove the plastic tie-wraps that are
securing the removable killing grid in place during transit. The
Select range should be mounted as shown in the mounting
options section of this document. Keep out of reach of
children.
Wall Mounting - Install the supplied wall plugs and screws to
the mounting surface, having first made sure that appropriate
wall plugs are used for specialist mounting materials, such as
plasterboard.
Over time, Ultraviolet light may discolour the mounting
surface. If this would be a problem, mount the supplied
backplate between the back of the flykiller and the wall.
Ceiling Suspension - Fit the suspension hooks to the top of the
unit, by first removing the two top screws, then replacing them
with the suspension hooks in place. Then fix the suspension
chains to the hooks. The Select range should be hung 2 - 3m
from the ground, so if the supplied chains do not allow this,
chains of appropriate length and strength should be sourced.
Once installed into position, use the removable mains lead
and plug to connect the Select range to an appropriate
power supply, as specified on the specification label found on
the flykiller.
CLEANING
CLEANING
SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM
THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly every
month. During cleaning the unit should be thoroughly wiped
down with a damp cloth, removing any build up of dirt.
Ensure the unit is completely dry before reconnecting it to the
power supply.
MOUNTING FIXING CENTRES
METHOD
SE22
SE44
Wall
150mm
365mm
Suspended 300mm
511mm
Select
Professional Electric Insect Control
Select
Mounting Options
Wall
Suspended