background image

Please read these instructions carefully and store in a safe 
place for future reference.

Select

As part of the Insect-O-Cutor

®

 brand of insect control 

products, the Select range is an effective and flexible range of 

professional flykillers which utilise highly effective Synergetic

®

 

UV tubes.  Constructed from coated mild steel or robust 

stainless steel, the Select range can be wall mounted or ceiling 

suspended.

Contents of package

- 1 x Insect-O-Cutor flykiller

- 1 x Mains cable (Type X)

- 2 x Wall mounting screws and wall plugs

- 2 x Suspension hooks

- 2 x Suspension chains

- 1 x Backplate

- 1 x High powered UV tube (SE22 - Fitted)

or

- 2 x High powered UV tubes (SE44 - Fitted)

WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)

INSECT CONTROL PRODUCTS
The Select range utilise high powered ultra violet tubes to 
attract flying insects and then electrocutes them on a killing 
grid, before collecting them in a removable catch tray.

WARNING
The Select range is not to be used by persons with reduced 

physical, sensory or mental capabilities, or lack of experience 

and training, unless they have been given instruction.

Children should be supervised to ensure they do not play with 
the appliance.

If the mains cable is damaged it must be replaced by a 
specialist mains cable available from Pelsis Ltd or your supplier.

The Select range must only be used in areas which are free of 
dust and any possible explosive vapour mixture, are suitable 
for indoor use only and are not suitable for use in barns, stables 
and similar locations.

POSITIONING AND GUIDANCE FOR USE
The Select range should ideally be fixed around two meters 
above the ground, preferably in the darkest place within the 
area to be protected.  Do not position the unit close to 
windows, skylights or other sources of light, or where it may be 
obscured by furniture, doors or other obstacles.

The Select range should ideally be in operation for 24 hours a 
day, ensuring your premises are kept free of flying insects.  
Insects are most attracted to the Select range units at night 
when there is no competition from daylight or other light 
sources.

GUARANTEE
The Select range has a five year guarantee and if maintained 

as recommended in these instructions should continue to work 

for many years*. Use of non-approved consumables may 

invalidate the guarantee.

*Excludes tubes and starters.  Does not cover breakdown due to misuse, incorrect operation 

or use in an incorrect application.

INSTALLATION

INSTALLATION SHOULD BE CARRIED OUT BY SERVICE 

PERSONNEL ONLY.

Before installation, first remove the plastic tie-wraps that are 

securing the removable killing grid in place during transit.  The 
Select
 range should be mounted as shown in the mounting 

options section of this document.  Keep out of reach of 

children.  

Wall Mounting - Install the supplied wall plugs and screws to 

the mounting surface, having first made sure that appropriate 

wall plugs are used for specialist mounting materials, such as 

plasterboard.  

Over time, Ultraviolet light may discolour the mounting 

surface.  If this would be a problem, mount the supplied 

backplate between the back of the flykiller and the wall.    

Ceiling Suspension - Fit the suspension hooks to the top of the 

unit, by first removing the two top screws, then replacing them 

with the suspension hooks in place.  Then fix the suspension 

chains to the hooks.  The Select range should be hung 2 - 3m 

from the ground, so if the supplied chains do not allow this, 

chains of appropriate length and strength should be sourced.

Once installed into position, use the removable mains lead 

and plug to connect the Select range to an appropriate 

power supply, as specified on the specification label found on 

the flykiller.

CLEANING
CLEANING 

SHOULD BE CARRIED OUT BY SERVICE PERSONNEL 

ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM 

THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly every 
month.  During cleaning the unit should be thoroughly wiped 
down with a damp cloth, removing any build up of dirt.  
Ensure the unit is completely dry before reconnecting it to the 
power supply.

MOUNTING FIXING CENTRES
METHOD 

 SE22 

 SE44

Wall 

 150mm 

 365mm

Suspended 300mm 

  511mm

Select

Professional Electric Insect Control

Select

Mounting Options

Wall

Suspended

Reviews: