Working with ARCANE device
"ARCANE" has two main operating modes: mode of signal search and the mode of finding
(localizing) the sources of signals detected by the device.
1. Turn on the device by pressing and holding the on/off
button located on the right side. As soon as you see the loading
screen-release the button (the firmware version is displayed at the
bottom of the loading screen). Upon successful loading ARCANE
automatically starts scanning the spectrum.
"ARCANE" automatically switches to the search mode of signals from video cameras.
Every detected suspicious signal is displayed on the "main screen" as
a colored "cell" with two rows of numbers inside. Fields of which are shone
in shades of red (depending on the degree of coincidence probability with
the "images" of cameras) and information about the detected suspicious
signal (bin-file).
«Main screen» consists of 3 pages of 25-cell arrays, which limits
the number of simultaneously detectable signals up
to 75. Page
number is displayed in a top-left corner. You can navigate through
pages by pressing either ">>" or "<<" buttons, which can be found at
the bottom of the "main screen". Battery charge level is displayed at
the top-right corner of the main screen.
2. The selection of any detected signal is performed by
pressing on a "cell" (selected cell will be marked with white outline),
which will give access to "B/W" and "Info" option buttons.
«B/W»
- Will add the selected "cell" to "white list". Selected cell
will be marked and transferred to the end of the array at the last
page.