Selco SBT-30F User Manual Download Page 2

2. Look through the 
    v iewfinder  as  shown
    b elow.

Vertical adjustment

to raise
(loosen)

to lower
(tighten)

1

5

4

3

2

ADJUSTMENT OF OBSCURATION 

Obscuration time control

CONFIRMATION OF OPERATION

After completion of the installation, confirm correct operation by suitable walk test. Refer to the following LED
indications during the walk test. Confirm tamper operation prior to replacing covers. Confirm system operation
with covers replaced.

NOTE: Conduct a Walk Test at least once a year

OUTLINE DIMENSION

9

TROUBLE SHOOTING GUIDE

SPECIFICATION

Caution: Obscuration time settings exceeding 70msec (exceeding a setting of 1) do

Set the obscuration time of the receiver by adjusting the obscuration time control

conditions where there are a lot of birds or wind blown material.

5

 ADJUSTMENT OF OPTICAL AXIS

The best adjustment of optical axis can be done by reading the output voltage of the 
monitor jack.

7

10

6

8

It is important to ensure correct optical alignment between the 
transmitter and receiver for proper operation.

HOW   TO   USE   THE   MONITOR   JACK

Scale 1

fast running at full

Scale 2

Scale 3

Scale 4

walking with quick

normal walking

slow action

speed(8.6m/s)

steps(1.2m/s)

(0.6m/s)

(0.2

0.4m/s)

to the required setting according to the sketch beside. The obscuration time should
be set lower to detect faster moving targets, however care should be taken to note
the environmental conditions as the obscuration time should be set higher to ignore 

not comply with the requirements in UL639, Instrusion Detection Units.

Possible cause

A  Remedy

Indication lamp of Transmitter
does not light.

Improper voltage of power supply

Check power supply and wiring

Power supply indication Lamp
of Receiver does not light.

Improper voltage of power supply

Check power supply and wiring

Alarm indication lamp does not
light even when the beams are
intercepted.

Remove the reflecting object or

Check two beams to intercept
at the same time.
Adjust obscuration time setting 
to be shorter.

Although alarm LED lights

Melted bridge on the signal

Check the wiring.

It needs to be repaired.

Alarm LED on the Receiver 
does not turn off.

Inadequate optical axis.
Shading objects between the

of the Transmitter and/or Receiver. 

Readjust the optical axis.
Remove the shading objects.

Clean optics with soft cloth.

Bad wiring connection.
Change of supply voltage.

Shading objects moving by wind

Unstable installation of the sensor
unit.
Incomplete optical axis adjustment.

Birds and other large flying objects
intercept the  beam.

Check the wiring connection.
Check the voltage (for stabilized
supply voltage.) 
Remove the shading objects or

Fix steadily.

Readjust the optical axis.

Readjust the obscuration time
to be longer or reposition.

Infrared beam from Transmitter is

sent into the Receiver.

Shorter obscuration time than that

Q  Symptom

Intermittent alarm.

intercepted, alarm does

when the beams are

not ring.

reflected on another object and 
   
Two beams are not intercepted 

set on the obscuration control.

at the same time.

Broken wires or short on the

(Wrong current on the signal wires)

connection

signal wires.

Transmitter and the Receiver.
Dirty cover or dirty reflection mirror

between the Transitter and the
Receiver.

change the place for installation
and the optical axis direction. 

change the place for installation.

 Protection range (outdoor)

 Distance allowance

 Infrared beam

 Detection system

 Light source

Interruption Period

 Power Input

 Power consumption

Operation Temperature 

 Tamper output

 Optical axis horizontal adjust

 Optical axis vertical adjust

 Collimator

 Measure for moisture/frost

functions

 Weight

2-Beam

2-beam simultaneous cut-off detection

Infrared LED

Relay contact, form 'C' contact rating
AC/DC 24V, 0.5A Max.

Normally closed voltage free contacts 50m A.

Finder ( peep window )

 Slit type cover,heater option

Monitor jack output,OK monitoring,AGC circuit,
Adjustable beam interruption time

800g(28.2oz) (Transmitter and Receiver)

Dimenstion(H   W   D)

SBT-30F

   350m
(1,148ft)

50~700 msec (Selectable)

DC 10.5V~28V

65mA

 Model

 Alarm  output

  80-100m
(262-328ft)

 1,100m
(3,608ft)

   650m
(2,132ft)

   40-60m
(131-196ft)

   5-30m
(16-98ft)

70mA

75mA

20

    10 

180

    90 

   450m
(1,476ft)

  30-40m
(98-131ft)

70mA

SBT-40F

SBT-60F

SBT-100F

-25 C~+55 C(-13  F~+131  F)

196.5   82   73.5mm (7.7"   3.2"   2.9")

Good  Sensitivity

Alarm Activated

Power LED (green) is on

Good LED (green) is on

Alarm (red) .Level (red) LED are on

Poor  Sensitivity

Level LED (green) is on

Operating

Conditions

Indication

Transmitter

Transmitting

Receiver

1. Insert the meter pins into the monitor jack. 
    ( pay attention to the polarity because of DC voltage )
2. a) Adjust the horizontal adjustment until the output is at a maximum.
    b) Adjust  the vertical adjustment screw to obtain best signal. 
    ( Do not interrupt beam by hands during the adjustment )
3. The following minimum voltages should be obtained to ensure best
    performance.0.85V for all of the SBT-XXF series.
    If this is not obtained then the transmitter and receiver should be 
    re-aligned.

Monitor Jack

1. Turn on the power supply after uninstallation.  
    Place the viewfinder on either right or left hand 
    side of the lens whichever makes easier viewing.

viewfinder

Transmitter

Channel  Switch

Receiver

2

Long distance

    stack up 
    protection

1

Long distance 

    protection

3

perimeter protection

3. Adjust the angle of the lens via the 
    Horizontal angle adjustment and the
    Vertical adjustment screw so that the
    sensor can be seen in the center of 
    the Viewfinder.This adjustment is carried
    out on both the Transmitter and Receiver.
    Confirm after adjustment that the green
    GOOD LED is on, otherwise alignment 
     should  be  readjusted. 

NOTE: After completion of optical adjustment,    

ensure that both filters on the receiver
are replaced to their original position 
behind the mirrors.

To avoid the mutual interference ofbeams,please set the beams at different channels,
when installing more than one pairs at the same time.
TR:Transmitter; RE:Receiver

  Examples of the installation as below.

73.5

67.0

196.5

82.0

38~50mm

10cm

CH1

CH4

CH2 CH3

CH1

CH4

CH2 CH3

   900m
(2,952ft)

    60-80m
(196-262ft)

75mA

SBT-80F

 100-150m
(328-492ft)

 1,600m
(5,249ft)

SBT-150F

80mA

SHENZHEN SUNWAVE ELECTRONICS CO., LTD.

http://www.sunwave.cc

CHINA

TEL: +86-755-8998-3101      FAX: +86-755-8998-3102

No.21 Plant, Da Wei Industrial Zone, Huang Ge Keng,

Heng Gang Town, Shenzhen

P/N

W.97.0058  Rev.: A