Sel SEL-WCS Manual Download Page 7

7

Date Code 20191014

Information Sheet

SEL-734W and SEL-WCS

Safety Information

Safety Information

Regulatory Information

The SEL-WCS is approved for use only with specific output power configura-
tions that have been tested and approved. Modifications to the SEL-WCS, the 
antenna system, and the power output that have not been explicitly specified by 
the manufacturer are not permitted and may render the radio noncompliant with 
applicable regulatory authorities. The radio equipment described in this manual 
emits radio frequency energy. Professional installation is required.

United States (FCC) 

Per FCC 15.19(a)(3) and (a)(4) This device complies with part 15 of the FCC 
Rules. Operation is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.

Per FCC 15.21, changes or modifications not expressly approved by the party 
responsible for compliance could void the user's authority to operate the equip-
ment.

Canada

                    

DANGER

Install fault transmitters and 
sensors in accordance with 
normal safe operating 
procedures. These instructions 
are not intended to replace or 
supersede existing safety or 
operating requirements. Only 
trained qualified personnel with 
knowledge of high voltage 
safety should install or operate 
fault transmitters.

CAUTION

Although the power level is low, 
concentrated energy from a 
directional antenna may pose a 
health hazard. Do not allow 
users to come closer than 23 cm 
(9 in) to the transmitter when it 
is operating.

DANGER

To ensure proper safety and 
operation, the equipment 
ratings, installation instructions, 
and operating instructions must 
be checked before 
commissioning or maintenance 
of the equipment. The integrity 
of any protective conductor 
connection must be checked 
before carrying out any other 
actions. It is the responsibility of 
the user to ensure that the 
equipment is installed, 
operated, and used for its 
intended function in the manner 
specified in this manual. If 
misused, any safety protection 
provided by the equipment may 
be impaired.

This device complies with Industry Canada 
license-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) 
this device may not cause interference, and 
(2) this device must accept any interference, 
including interference that may cause unde-
sired operation of the device.

Le présent appareil est conforme aux CNR 
d'Industrie Canada applicables aux appareils 
radio exempts de licence. L'exploitation est 
autorisée aux deux conditions suivantes : (1) 
l'appareil ne doit pas produire de brouillage ; 
(2) l'utilisateur de l'appareil doit accepter tout 
brouillage radioélectrique subi, même si le 
brouillage est susceptible d'en compromettre 
le fonctionnement.

Per RSS-Gen, Radio apparatus shall comply 
with the requirements to include required 
notices or statements to the user of equipment 
with each unit of equipment model offered for 
sale.

Selon RSS-Gen, un appareil radio doit être 
conforme avec les exigences d'inclure requis 
avis ou déclarations à l'utilisateur de l'équipe-
ment avec chaque unité de modèle d'équipe-
ment offert pour vente.

These statements are required regarding 
antennas and for certain types of equipment. 
Please see the specified sections of RSS-Gen 
for details and suggested verbiage: Transmit-
ter Antenna -Section 6.8

Ces déclarations sont obligatoires concernant 
antennes et pour certains types d'équipement. 
Veuillez consulter les sections spécifiées de 
RSS-Gen pour plus de détails et le verbiage 
suggéré: Emetteur Antenne - Section 6.8

Devices operating in the 5250 - 5350 MHz 
band shall be labeled "for indoor use only". 
Alternatively, that text can be included in the 
user manual and not on the device. Note how-
ever the user manual is the only option avail-
able for devices operating in the 5150 - 5250 
MHz band. In all cases the user manual shall 
contain instructions "for indoor use only".

Périphériques fonctionnant dans la bande 
5250 - 5350 MHz la bande doit porter la men-
tion "pour utilisation à l'intérieur unique-
ment". Alternativement, ce texte peut être 
inclus dans le manuel de l'utilisateur et non 
sur l'appareil. Notez cependant le manuel 
d'utilisation est la seule option disponible 
pour les appareils fonctionnant dans le 5150 – 
5250 Bande MHz. Dans tous les cas, le man-
uel d'utilisation doit contient des instructions 
"pour une utilisation en intérieur uniquement".

Summary of Contents for SEL-WCS

Page 1: ...w the SEL 734W and the SEL 734B differ refer to the sections below SEL Wireless Current Sensor SEL WCS Overview The SEL WCS provides measurement of power line current both for the funda mental frequen...

Page 2: ...allows the SEL WCS to be mounted on the line or removed from the line using only a shotgun stick The springs simplify installa tion on overhead lines and hold the SEL WCS in position See SEL WCS Inst...

Page 3: ...L 734W Figure 2 shows an SEL 734W The orange rectangle in the figure indicates the switches where you make the different settings from those on the SEL 734B Settings Settings are made on both the SEL...

Page 4: ...associated with each Network ID DIP switches SW1 SW4 shown in Figure 2 are for the Network ID Harmonic Content DIP Switch Setting DIP switch SW7 configures the SEL WCS whether it calculates and sends...

Page 5: ...ta available Distance to Sensor The Distance to Sensor setting is used to ensure that an SEL 734W does not hear data from an SEL WCS on the system that has reused the Network ID of the SEL WCS associa...

Page 6: ...ce is closed around the line The spring mechanism should be pushed in so that it wraps around the line Step 3 Apply slight upward pressure until the device is secured around the line as shown in Figur...

Page 7: ...may be impaired This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device...

Page 8: ...ical shock resulting in injury or death DANGER D brancher tous les raccordements externes avant d ouvrir cet appa reil Tout contact avec des tensions ou courants internes l appareil peut causer un cho...

Page 9: ...self your work surface and this equip ment before removing any cover from this equipment If your facility is not equipped to work with these components contact SEL about returning this device and rela...

Page 10: ...odulation FSK Link Range TBD Type Tests Electromagnetic Compatibility Emissions Radiated 47 CFR Part 15 109 Class A Conducted 47 CFR Part 15 107 Class A Electromagnetic Compatibility Immunity Electros...

Page 11: ...ate Code 20191014 Information Sheet SEL 734W and SEL WCS SEL WCS Specifications Table 2 Certifications by Country Country Part Number Authority Reference U S A and Colombia TBD FCC TBD Canada TBD IC T...

Reviews: