![Sekotech GCU-OCD15 Operating Manual Download Page 3](http://html1.mh-extra.com/html/sekotech/gcu-ocd15/gcu-ocd15_operating-manual_1236357003.webp)
3
Operating manual (OM) worked out to provide correct and safe operation
of device
for observation hidden television systems
GCU-OCD15
(further
in the text “device” or “instrument”) and to carry out the evaluation of
the Instrument technical condition with the goal to make decision whether it
should be sent for repair. No additional training of the operator is required.
1.
DESCRIPTION AND PRINCIPLE OF OPERATION
1.1 Area of application
1.1.1. Detector of hidden television surveillance systems
GCU-OCD15
is
designed for searching and visualizing the location of portable hidden television
surveillance systems (HTSS), such as cameras hidden in the walls or furniture,
button, icon, briefcase or handbag, with a conventional lens or micro lens
(pin-hole type), enabled or disabled, transmitting image via wire or radio
channel, and operating indoors in mild climate.
1.2. Technical parameters
1.2.1. Minimum diameter of HTSS pupil detected 1 mm.
1.2.2. Detection range:
- minimum - 2 ± 0,1 m;
- maximum - 25 ± 0,5 m.
1.2.3. Operating observation field 8°.
1.2.4. Maximum zoom 4.
1.2.5. Probing LEDs radiation with white LED.
1.2.6. Power from one CR123A battery.
1.2.7. Power supply voltage from 2.5 to 3 V.
1.2.8. Continuous operation under standard climatic conditions from a new battery
at least 10 hours.
1.2.9. The product has the following functions and settings:
- eyepiece diopter adjustment ± 5 diopters;
- continuous radiation mode;
- pulse radiation mode.
1.2.10. Time to enable operation mode after switching, no more than 5 seconds.
1.2.11. Dimensions, no more than 80x70x45 mm.
1.2.12. Overall dimensions of the standard package (cover) no more than
130x80x60 mm.
1.2.13. Weight of the device with standard batteries, no more than 0.25 kg.
1.2.14. Weight of the product in standard package with battery, no more than
0.5 kg.
1.2.15. Climatic conditions:
- Relative humidity no more than 95% at temperature 25 ° C;
- operating temperature range from -10 ° C to + 50 ° C.