Sekotech GCU-OCD15 Operating Manual Download Page 3

Operating  manual  (OM)  worked  out  to  provide  correct  and  safe  operation 

of  device

 

for  observation  hidden  television  systems 

GCU-OCD15 

  (further 

in  the  text  “device”  or  “instrument”)  and  to  carry  out  the  evaluation  of 
the  Instrument  technical  condition  with  the  goal  to  make  decision  whether  it 
should be sent for repair. No additional training of the operator is required. 

1.

 

DESCRIPTION AND PRINCIPLE OF OPERATION

1.1 Area of application

1.1.1. Detector of hidden television surveillance systems 

GCU-OCD15 

 is 

designed for searching and visualizing the location of portable hidden television 
surveillance systems (HTSS), such as cameras hidden in the walls or furniture, 
button, icon, briefcase or handbag, with a conventional lens or micro lens 
(pin-hole type), enabled or disabled, transmitting image via wire or radio 
channel, and operating indoors in mild climate. 

1.2. Technical parameters 

1.2.1. Minimum diameter of HTSS pupil detected 1 mm. 
1.2.2. Detection range: 
- minimum - 2 ± 0,1 m;
- maximum - 25 ± 0,5 m.
1.2.3. Operating observation field 8°.
1.2.4. Maximum zoom 4.
1.2.5. Probing LEDs radiation with white LED.
1.2.6. Power from one CR123A battery.
1.2.7. Power supply voltage from 2.5 to 3 V.
1.2.8. Continuous operation under standard climatic conditions from a new battery
at least 10 hours.
1.2.9. The product has the following functions and settings:
- eyepiece diopter adjustment ± 5 diopters;
- continuous radiation mode;
- pulse radiation mode.
1.2.10. Time to enable operation mode after switching, no more than 5 seconds.
1.2.11. Dimensions, no more than 80x70x45 mm.
1.2.12. Overall dimensions of the standard package (cover) no more than
130x80x60 mm.
1.2.13. Weight of the device with standard batteries, no more than 0.25 kg.
1.2.14. Weight of the product in standard package with battery, no more than
0.5 kg.
1.2.15. Climatic conditions:
- Relative humidity no more than 95% at temperature 25 ° C;
- operating temperature range from -10 ° C to + 50 ° C.

Summary of Contents for GCU-OCD15

Page 1: ...Detector of Hidden Television Surveillance Systems GCU OCD15 Operating manual CONTENT...

Page 2: ...hnical parameters 3 1 3 Delivery set 4 1 4 Principal of operation 4 1 5 Marking 5 1 6 Packing 5 2 PROPER USE 5 2 1 Operational restrictions 5 2 2 Getting started 5 2 3 Product use 6 2 4 Safety measure...

Page 3: ...te 1 2 Technical parameters 1 2 1 Minimum diameter of HTSS pupil detected 1 mm 1 2 2 Detection range minimum 2 0 1 m maximum 25 0 5 m 1 2 3 Operating observation field 8 1 2 4 Maximum zoom 4 1 2 5 Pro...

Page 4: ...of the device and control layout are shown in Figure 1 Figure 1 Table 1 Name Pcs Note GCU OCD15 1 CR123 battery 1 Cloth for cleaning optics 1 Operation Manual 1 Data sheet 1 Delivery package cover 1 B...

Page 5: ...1 5 2 The product is sealed on a standard package cover The product itself is not sealed 1 6 Packing 1 6 1 The product is packed in a standard package cover 1 6 2 The product in a standard package is...

Page 6: ...device power off the device and to take measures to put out fire 2 4 2 In case of emergency operating conditions high temperature humidity vibration etc take measures to reduce the impact of accidenta...

Page 7: ...wed 5 2 Storage life 5 2 1 Storage life of the product in a standard package is 1 year without batteries in heated ventilated premises at ambient temperature from 50 C to 40 C and a relative humidity...

Page 8: ...nd transporting the requirements of handling marks on the shipping container must be strictly observed 6 3 Transport characteristics of the product 6 3 1 Dimensions of the product in the standard pack...