value is shown. Use the 

 

and 

 

keys to change the value and

press the 

 

key to save your entry. A larger value of damping

will slow down the flickering of the displayed digits but result in
a slower response to depth changes. The display damping limits
are 5 to 20 with 10 being the default value.

Selecting NMEA 0183 or External Alarm Output:
The NMEA 0183 serial data line can be programmed to
function as an external alarm output
To toggle the data line between NMEA 0183 and External
Alarm Output, press and hold down both the 

 

and 

 

 

keys

for 10 seconds (until you hear a long beep). The display will
briefly show "dAtA" / or "E-AL" to show you which mode is
selected. The new output mode is automatically saved to
memory. A 5V signal (10 mA Max.) is output whenever an
alarm condition exists and the alarms are enabled.

NMEA 0183 Sentence:
The SW RP05 outputs serial data of depth in NMEA 0183 format.
The sentence is output in the following format:

Depth: 

$SDDPT,xxx.x,yyy.y*CS

xxx.x = Depth in Metres yyy.y = Keel offset in Metres
*CS = Check Sum

Notes and Warnings:
a) The displayed depth should be used as a guide and cannot
always be relied on to be correct. Surface clutter, schools of
fish, air bubbles under the transducer caused by other boats,
thermoclines and high speed operation of your boat can cause
the depthsounder to mis-read.
b) A display of " 

- - - - 

" means the unit has not acquired or

is no longer able to track the bottom.

Other Seiwa Products

l

Is possible to connect to 

SW RP05

,  to all the Seiwa multifunction chartplotters and use it for take the 

deep value. Another equipment it's the:

SW RP03 NMEA repeater

Summary of Contents for SW RP05

Page 1: ...SW RP05 ...

Page 2: ...ms built in and can display the depth in feet metres or fathoms A keel offset from 20 0 to 20 0 feet can be entered so the SW RP05 shows the depth below the surface below the keel or below the transducer Under 20 feet Meters or Fathoms the depth is displayed in tenths The SW RP05 outputs NMEA 0183 serial data as a standard SDDPT Depth below the transducer sentence If not required the NMEA 0183 dat...

Page 3: ...display damping NMEA 0183 Out SDDPT Depth below transducer Installation Before starting the installation please read this entire section first Finger tighten the screws that mount the instrument bracket It is not necessary or recommended to use tools Drill a 2 1 8 55mm mounting hole where you desire to mount the instrument Figure 1 Connect the various wires from Cable 1 and Cable 2 as shown in Fig...

Page 4: ...s on off set alarms values set change keel offset and display damping New information is automatically saved to non volatile memory Turning Alarms ON OFF Press the key 1 2 second to turn alarms ON The alarm icon will light Press the key 1 2 second to turn the alarms and alarm icon OFF Backlight Intensity ...

Page 5: ...d keys to set the desired alarm value Press the key to save the deep depth alarm value to memory Setting Anchor Drag Alarm After anchoring set the shallow alarm a few feet more shallow than the actual displayed depth Similarly set the deep alarm a few feet deeper than the actual displayed depth Make allowances for local tidal changes to prevent false alarms Setting Keel Offset While viewing Depth ...

Page 6: ...saved to memory A 5V signal 10 mA Max is output whenever an alarm condition exists and the alarms are enabled NMEA 0183 Sentence The SW RP05 outputs serial data of depth in NMEA 0183 format The sentence is output in the following format Depth SDDPT xxx x yyy y CS xxx x Depth in Metres yyy y Keel offset in Metres CS Check Sum Notes and Warnings a The displayed depth should be used as a guide and ca...

Reviews: