SC-­‐OM-­‐V614

 

   
   

   TEMPERATURE   &   PRESSURE   RELIEF   VALVES         

   

Neither   Seisco   nor   the   national   code   requires   a   

combination

   temperature   and   pressure   relief   

valve   for   this   appliance,   however   local   codes   may   require   it.      

HOWEVER,

   

WHEN   INSTALLING   

THE   SEISCO   IN   ANY   AREA   THAT   IS   NOT   READILY   VISIBLE   OR   ROUTINELY   MONITORED   
INCLUDING   CLOSETS,   CABINETS,   ATTICS   OR   ANY   OTHER   AREAS   WHERE   LEAKS   OF   ANY   
NATURE   COULD   CAUSE   PROPERTY   DAMAGE,   A   150-­‐PSI   MAXIMUM   PRESSURE   RELIEF   
VALVE   WITH   DRAIN   LINE   

IS   

REQUIRED.   

 

The   discharge   from   the   temperature   and/or   pressure   relief   valve   should   be   piped   to   the   
ground   or   into   a   drain   system   to   prevent   exposure   or   possible   burn   hazards   to   humans   or   
other   plant   or   animal   life.   Follow   local   codes.   Water   discharged   from   the   relief   valve   could   
cause   severe   burns   instantly,   scalds,   or   death.   

 

The   temperature   and/or   pressure   relief   valve   must   be   manually   operated   once   a   year   to   
check   for   correct   operation.      

 

The   temperature   and/or   pressure   relief   valve   should   be   added   to   the   hot   water   outlet   line   
according   to   the   manufacturer’s   instructions.   DO   NOT   place   any   other   type   valve   or   shut   
off   device   between   the   relief   valve   and   the   water   heater.      

 

Do   not   plug   the   temperature   and/or   pressure   relief   valve   and   do   not   install   any   reducing   
fittings   or   other   restrictions   in   the   relief   line.   The   relief   line   should   allow   for   complete   
drainage   of   the   valve   and   the   line.      

 

If   a   temperature   and/or   pressure   relief   valve   discharges   periodically,   this   may   be   due   to   
thermal   expansion   in   a   closed   water   supply   system.   Contact   the   water   supplier   or   local   
plumbing   inspector   on   how   to   correct   this   situation.   Do   not   plug   the   relief   valve.      

 

   

DRAIN   PAN   

   
The   Seisco   heater   must   be   located   in   an   area   where   water   leakage   of   the   unit   or   connections   will   
not   result   in   damage   to   the   area   adjacent   to   the   appliance   or   to   lower   floors   of   the   structure.      
When   such   locations   cannot   be   avoided,   it   is   

required

   that   a   suitable   drain   pan,   adequately   

drained,   be   installed   under   the   appliance.      A   splash   cover   must   be   included   to   protect   the   area   of   
attachment   to   the   wall.      The   pan   must   be   large   enough   to   protect   the   area   below   the   heater   and   
must   be   piped   to   a   suitable   drain   with   the   complete   drain   pan/splash   cover/pipe/drain   
combination   sufficient   to   contain   the   full   flow   of   the   supply   line   in   the   event   of   a   leak   and   
sufficient   to   prevent   any   property   damage.   

Summary of Contents for SC70

Page 1: ...NTY OF YOUR UNIT WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE UNIT HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES DUE TO FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES THE INSTALLATION MUST CONFORM TO ALL INSTRUCTIONS IN THIS MANUAL AND TO ALL LOCAL A...

Page 2: ...US INJURY IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR CONSULT QUALIFIED PERSONNEL HAZARD OF ELECTRICAL SHOCK BEFORE REMOVING THE COVER OR SERVICING THE UNIT MAKE SURE THE ELECTRICAL SUPPLY TO THE WATER HEATER IS DISCONNECTED FAILURE TO DO THIS COULD RESULT IN DEATH SERIOUS BODILY ...

Page 3: ...ONTENTS General Safety Inside Cover Introduction to the SEISCO WATER HEATER 1 Features and Benefits 2 DOs and DON Ts 3 Installation Guide 4 Electrical Installation 6 Limited Warranty 11 Warranty Claims Procedure 12 Troubleshooting Guide 13 Product Specifications 14 Wiring Diagrams 15 Service Warranty Information Back Cover ...

Page 4: ...ian period are inherrently inadequate for the lifestyle enjoyed by most of the Western world Only in the past several years has technology advanced to the point that Metal parts used in demanding applications can be replaced with glass fiber reinforced heat stabilized nylon resin Micro control has reached a new high level of speed and proficiency The SEISCO uses a patented technology that combines...

Page 5: ...water in water heating applications ANOTHER WAY YOU SAVE Because of the state of the art design you can expect a long service life from the heater components All maintenance even major requirements including replacement of the electronic control board can easily be diagnosed and completed in minutes In the unlikely event you do have a problem the ten year limited warranty READ YOUR WARRANTY assure...

Page 6: ...t any mineral deposits from the chambers NEVER POUR OR SPRAY LIQUIDS DIRECTLY ON THE UNIT THAT MIGHT ENTER THE CASE POSSIBLY CAUSING DAMAGE TO YOUR UNIT Your Supercharger is designed for safe operation and ease of service Qualified service personnel must service your unit only BEFORE YOUR UNIT IS TO BE SERVICED ALWAYS TURN OFF ALL MAIN POWER CIRCUIT BREAKERS TO THE UNIT After servicing always RUN ...

Page 7: ...ittings on top or tilted up slightly with the water fittings up to 3 higher in the vertical position as shown in figure 2 Be sure to allow adequate clearance and proper orientation for field wiring installation and inspection Mount at least 6 from all surrounding surfaces and 18 from the flue of a gas water heater Unit must be mounted in dry conditioned space to protect from freezing Use a pressur...

Page 8: ...gasket and seal with Teflon tape For other adapters be sure to use 3 4 NPT fittings and seal with TEFLON TAPE ONLY Connect plumbing to the adapters with Teflon tape Do not reduce below for whole house extender applications to avoid flow restrictions 3 Flex pipe is recommended for ease of installation and service Where fixed pipe is used a plumbing union is recommended for ease of service 4 Always ...

Page 9: ...her type valve or shut off device between the relief valve and the water heater Do not plug the temperature and or pressure relief valve and do not install any reducing fittings or other restrictions in the relief line The relief line should allow for complete drainage of the valve and the line If a temperature and or pressure relief valve discharges periodically this may be due to thermal expansi...

Page 10: ...oper wiring Proper connectors should be chosen for the wire conduit selected Connect properly sized copper leads to the terminal block as shown Connect the power circuits to L1 and L2 as shown and the ground to GND For 120V models connect the Neutral to L2 N on the terminal block PRE POWER CHECK Verify that all connections are secure Verify that an adequate ground has been properly connected Verif...

Page 11: ...on the water temperature in the tank and the combined heating capacity of the primary heating source PLUS the Supercharger The performance chart demonstrates as the water temperature in the tank declines the combined capacity to provide hot water flow also declines but remains more than sufficient to provide that hot water needed to allow for a tempered 105 F hot shower Endlessly SUPERCHARGER PERF...

Page 12: ...SCO models rated 5KW to 28KW are designed to operate from a 208V to 240V power supply Connect a voltmeter at power circuit 1 CKT 1 between L1 and L2 For models with multiple power circuits utilized continue to check voltage at each additional power circuit OPERATIONAL CHECKS Turn water on MEDIUM LOW utilizing any sink allowing water to run for a couple of minutes to ensure that all air is purged f...

Page 13: ... are not turned on especially heaters with multiple circuits Incoming power wires to the water heater are out of phase heaters with multiple circuits Water supply valve not turned on no water in the heater chamber Water supply lines are reversed hot and cold reversed shipping plugs installed Water supply connection s are leaking T P Relief Valve where required by local code is leaking or stuck ope...

Page 14: ...r has been installed and the operational checks are completed the output of the hot water can be measured and adjusted if necessary The temperature adjusting knob can be found on the left side of the control board The factory setting is usually between 118 and 122 degrees F The knob will usually be in the 2 to 3 o clock position Turning the knob to the left decreases the temperature and turning it...

Page 15: ...repair Only Seisco can authorize the replacement of the product If a component or product returned to Seisco is found to be free of defects in material or workmanship the warranty claim may be denied How do I get service You must contact Seisco or an authorized service provider for the repair of a product under this Warranty For the name of a service provider please contact your place of purchase ...

Page 16: ...eturn shipment must have the RMA number clearly marked on the package or it may be refused If service personnel have repaired the unit to operable condition with their own inventory Seisco International Limited upon receipt of defective parts will replace or issue credit for those parts verified to be under warranty Owner must promptly notify the installing contractor dealer to obtain service unde...

Page 17: ... MAIN POWER BREAKERS may be tripped BAD Heating Element or Temperature Sensor CIRCUIT BOARD failure Reduce flow Turn off power and run water for 5 minutes Check power panel Reset breaker if tripped Call local service contractor Call local service contractor Hot water temperature fluctuates FLOW is too high ONE OF THE MAIN POWER BREAKERS may be tripped BAD Heating Element BAD Temperature Sensor Red...

Page 18: ...ight Width Depth Pipe Size NPT Approx Shipping Weight One Chamber 7 5 15 6 5 9 lbs Model Number Kilowatts KW Voltage VAC Maximum Amperes AMPS Circuit Breakers SC 70 7 0 240 30 2 pole 30A SC 90 9 0 240 38 2 pole 40A RATINGS ELECTRICAL PHYSICAL DESCRIPTION ...

Page 19: ...SC OM V614 16 WIRING DIAGRAM SUPERCHARGER ...

Page 20: ...__________________________________________ NOTES AND SERVICE Your SEISCO can be serviced by most major brand authorized appliance repair or heating and plumbing centers in your area If your preferred service center does not already have service information Seisco International Limited will upon request and with no charge promptly fax the information to the service center For information regarding ...

Reviews: