Seisco RA-14 Owner'S Manual Download Page 4

 

 

RA-­‐OM-­‐713

 

   
   

   
   

   
   
   

   
   
   

   
   

   
   
   

   
   
   

   
   

   
   
   

   
   

   
   
   

   
   
   

   
   

   
   
   

   
   

   
   
   

   
   
   

   
   

   
   

INTRODUCTION   TO   SEISCO

   

   

Congratulations   on   your   purchase   of   the   

   

SEISCO

®

   ON-­‐DEMAND   TANKLESS   WATER   HEATER

   

   

You   are   now   in   a   rapidly   growing   and   highly   discriminating   group   of   individuals   and   businesses   that:   

Prefer   the   freedom   of   managing   ones   own   lifestyle   through   technologically   advanced   equipment   

Have   the   need   and   desire   for   hot   water   WHEN   they   want   it   from   an   ENDLESS   SUPPLY.   

   

No   more   waiting,   no   more   running   out   of   hot   water.   

   

Early   civilization   relied   on   hot   water   springs   to   supply   all   the   hot   water   needed   for   cleansing   and   for   

therapeudic   purposes.      However,   as   civilization   progressed,   the   accepted   method   of   producing   hot   

water   has   become   restrictive   –   the   storage   tank   water   heater.      We   have   become   conditioned   to   the   

statement   “We   can’t   do   the   laundry   after   the   family   showers”.   Or   in   the   winter   months,   “I   have   to   

wait   an   hour   for   enough   hot   water   to   take   my   shower”      

   

For   the   past   70   years   little   change   has   been   made   in   the   most   common   water   heater   delivery   system,   

the   cumbersome   inefficient   storage   tank   heater   that   still   delivers   only   a   LIMITED   SUPPLY   OF   HOT   

WATER.      Even   the   classic   flow   through   water   heaters   around   since   the   Victorian   period   are   

inherrently   inadequate   for   the   lifestyle   enjoyed   by   most   of   the   Western   world.   

      

Only   in   the   past   several   years   has   technology   advanced   to   the   point   that:   

Metal   parts   used   in   demanding   applications   can   be   replaced   with   glass   fiber   reinforced,   heat   

stabilized   nylon   resin.   

Micro-­‐control   has   reached   a   new   high   level   of   speed   and   proficiency   

   
The

   SEISCO

®

   

uses   a   patented*   technology   that   combines   and   implements   the   best   of   both.   

   

Only   SEISCO   has   been   able   to   develop   a   water   heater   that   is   inherently   highly   energy   efficient,   modular,   

rust   free,   scale   resistant,   and   endlessly   responsive   to   the   varying   demands   of   flow.   

   

The   development   of   such   a   system   was   no   small   task.   Your

   SEISCO

®

   heater’s   patented   technology   

represents   the   culmination   of   over   10   years   and   millions   of   dollars   of   intensive   development   and   testing.      

We   have   outlined   what   we   think   are   major   benefits   in   this   manual.   After   reading   the   manual,   YOU   

DECIDE   which   is   the   most   important   to   you.   

   
Congratulations   again.   We   know   you   are   already   beginning   to   enjoy   the   benefits   of   your   new   

   

SEISCO   CONTINUOUS   WATER   HEATING   SYSTEM   

   

*U.S.   Patents

:               #6,246,831   issued   June   12,   2001;   

#6,080,971   issued   June   23,   2000;      

#5,866,880   issued   February   2,   1999;      

#5,325,822   issued   July,   1994;      

#5,216,743   issued   June,   1993.         

In   addition   to   the   U.S.   patents,   there   are   many   foreign   patents   issued   and   in   process.      
   

Summary of Contents for RA-14

Page 1: ...TY OF YOUR UNIT WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE UNIT HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES DUE TO FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES THE INSTALLATION MUST CONFORM TO ALL INSTRUCTIONS IN THIS MANUAL AND TO ALL LOCAL AN...

Page 2: ...EM MAY RESULT IN DEATH OR SERIOUS INJURY IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR CONSULT QUALIFIED PERSONNEL HAZARD OF ELECTRICAL SHOCK BEFORE REMOVING THE COVER OR SERVICING THE UNIT MAKE SURE THE ELECTRICAL SUPPLY TO THE WATER HEATER IS DISCONNECTED FAILURE TO DO THIS COULD ...

Page 3: ...eneral Safety Inside Cover Introduction to the SEISCO WATER HEATER 1 Features and Benefits 2 DOs and DON Ts 3 Installation Guide 4 Electrical Installation 6 Limited Warranty 11 Warranty Claims Procedure 12 Troubleshooting Guide 13 Product Specifications 14 Parts Diagrams 15 Wiring Diagrams 17 Service Warranty Information Back Cover ...

Page 4: ...he Victorian period are inherrently inadequate for the lifestyle enjoyed by most of the Western world Only in the past several years has technology advanced to the point that Metal parts used in demanding applications can be replaced with glass fiber reinforced heat stabilized nylon resin Micro control has reached a new high level of speed and proficiency The SEISCO uses a patented technology that...

Page 5: ...ter in water heating applications ANOTHER WAY YOU SAVE Because of the state of the art design you can expect a long service life from the heater components All maintenance even major requirements including replacement of the electronic control board can easily be diagnosed and completed in minutes In the unlikely event you do have a problem the ten year limited warranty READ YOUR WARRANTY assures ...

Page 6: ...achable base plates and clean out any mineral deposits from the chambers NEVER POUR OR SPRAY LIQUIDS DIRECTLY ON THE UNIT THAT MIGHT ENTER THE CASE POSSIBLY CAUSING DAMAGE TO YOUR UNIT Your SEISCO is designed for safe operation and ease of service Qualified service personnel must service your unit only BEFORE YOUR UNIT IS TO BE SERVICED ALWAYS TURN OFF ALL MAIN POWER CIRCUIT BREAKERS TO THE UNIT A...

Page 7: ...wood screws to attach the water heater to the plywood PROPERTY DAMAGE PROTECTION WHEN INSTALLING THE SEISCO IN ANY AREA THAT IS NOT READILY VISIBLE OR ROUTINELY MONITORED INCLUDING CLOSETS CABINETS ATTICS OR ANY OTHER AREAS WHERE LEAKS OF ANY NATURE COULD CAUSE PROPERTY DAMAGE A 150 PSI MAXIMUM PRESSURE RELIEF VALVE WITH DRAIN LINE AND A DRAIN PAN AND DRAIN LINE SUITABLE FOR CONTAINING THE FLOW OF...

Page 8: ... not install any reducing fittings or other restrictions in the relief line The relief line should allow for complete drainage of the valve and the line If a temperature and or pressure relief valve discharges periodically this may be due to thermal expansion in a closed water supply system Contact the water supplier or local plumbing inspector on how to correct this situation Do not plug the reli...

Page 9: ...ONNECT ALL POWER SUPPLIES BEFORE SERVICING IF USING STRANDED WIRE MAKE SURE THAT ALL STRANDS ARE IN SECURELY PLACED IN THE TERMINAL BLOCK A LOOSE STRAND IN CONTACT WITH THE CIRCUIT BOARD CAN IMPAIR PERFORMANCE OR DAMAGE THE BOARD HEATER SUPPLY SIDE CONNECTION FOR TWO CHAMBER MODELS INSTALLED WITH A SINGLE BREAKER AND WITH JUMPERS INSTALLED ON THE CIRCUIT BOARD ONE PAIR OF WIRES SHOULD BE ATTACHED ...

Page 10: ...al wires entering the heater from the side 3 Mounting Height For safety ease of installation and service the suggested height above the floor is 42 to 48 inches minimum 10 inches Do not install electrical disconnect or sub panels below heater as this may interfere with access to the clean out plates located under the heater 4 Front Clearance In the absence of a door or removal access panel in fron...

Page 11: ...ed 5KW to 28KW are designed to operate from a 208V to 240V power supply Connect a voltmeter at power circuit 1 CKT 1 between L1 and L2 For models with multiple power circuits utilized continue to check voltage at each additional power circuit OPERATIONAL CHECKS Turn water on MEDIUM LOW utilizing any sink allowing water to run for a couple of minutes to ensure that all air is purged from the unit Y...

Page 12: ...ircuit breakers are not turned on especially heaters with multiple circuits Incoming power wires to the water heater are out of phase heaters with multiple circuits Water supply valve not turned on no water in the heater chamber Water supply lines are reversed hot and cold reversed Water supply connection s are leaking T P Relief Valve where required by local code is leaking or stuck open THE SEIS...

Page 13: ...ing when selecting multiple Seisco heaters for a high flow application Refer to the Electrical Service Requirements and Sample Load Calculations section in the Product Guide Typical Flow Use Rates in Gallons per Minute GPM Fixture Type Lavatory Bathtub Shower Kitchen Sink Pantry Sink Laundry Sink Dishwasher Flow Rates 0 5 1 5 2 0 4 0 1 5 3 0 1 0 1 5 1 5 2 5 2 5 3 0 1 0 3 0 TEMPERATURE ADJUSTMENT A...

Page 14: ...ONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU This warranty gives you specific legal rights and you may have other rights THAT vary from state to state These warranties shall be void and have no effect If the SEISCO heater is not used for its intended application If the design or structure of the SEISCO heater is modified or altered in any way If appliances or equi...

Page 15: ...turn shipment must have the RMA number clearly marked on the package or it may be refused If service personnel have repaired the unit to operable condition with their own inventory Seisco International Limited upon receipt of defective parts will replace or issue credit for those parts verified to be under warranty Owner must promptly notify the installing contractor dealer to obtain service under...

Page 16: ...Reset if tripped Check power panel Reset breaker if tripped Call local service contractor Call local service contractor Hot water temperature fluctuates FLOW is too high ONE OF THE MAIN POWER BREAKERS may be tripped BAD Heating Element BAD Temperature Sensor Reduce flow Check power panel Reset breaker if tripped Call local service contractor Call local service contractor Do not attempt to fill a l...

Page 17: ...75 2 2 pole 40A1 1 2 pole 75A RA 22 22 240 91 4 2 pole 25A1 2 2 pole 50A RA 28 28 240 116 4 2 pole 30A 2 2 pole 60A1 RA 32 32 240 134 4 2 pole 40A 2 2 pole 70A1 1 Optional wiring method shown in italics VERIFY CORRECT JUMPER INSTALLATION on control board when using a single breaker for two Chamber Models or 2 breakers for Four Chamber models Be sure to REMOVE JUMPERS when using two breakers for tw...

Page 18: ...s 8 ea 12 LED Light Indicator 13 Audible Speaker 14 Output Temperature Control 15 Microprocessor Control Chip LEGEND 16 Blue Button Manual Audible Activation 17 Terminal Spades for Leak Detect Wires 18 Triacs 4 each 19 Triac Mounting Blocks to Heat Sink 4 ea 20 Copper Heat Sink Tube L1 Power Connection Lugs 208 240 VAC L2 Power Connection Lugs 208 240 VAC Limit Over Temperature Limit Switches 2 TH...

Page 19: ...Heating Element Relays 4 8 Transformer 9 LED Light Indicator 10 Audible Speaker 11 Output Temperature Control 12 Microprocessor Control Chip 13 Blue Button Manual Audible Activation LEGEND 14 Triacs 2 15 Triac Mounting Blocks to Heat Sink 2 16 Copper Heat Sink Tube L1 Power Connection Lugs 208 240 VAC L2 Power Connection Lugs 208 240 VAC Limit Over Temperature Limit Switch TH IN Inlet Temperature ...

Page 20: ...RA OM 713 17 WIRING DIAGRAMS TWO CHAMBER SINGLE CIRCUIT IMPORTANT NOTE Jumpers must be INSTALLED on the circuit board in this configuration ...

Page 21: ...RA OM 713 18 WIRING DIAGRAMS TWO CHAMBER DUAL CIRCUITS IMPORTANT NOTE Jumpers must be REMOVED from the circuit board in this configuration ...

Page 22: ...RA OM 713 19 WIRING DIAGRAMS FOUR CHAMBER DUAL CIRCUITS IMPORTANT NOTE Jumpers must be INSTALLED on the circuit board in this configuration ...

Page 23: ...RA OM 713 20 WIRING DIAGRAMS FOUR CHAMBER FOUR CIRCUITS IMPORTANT NOTE Jumpers must be REMOVED from the circuit board in this configuration ...

Page 24: ...________________________________________ NOTES AND SERVICE Your SEISCO can be serviced by most major brand authorized appliance repair or heating and plumbing centers in your area If your preferred service center does not already have service information Seisco International Limited will upon request and with no charge promptly fax the information to the service center For information regarding se...