Seisco CA-10-208-3P Owner'S Manual Download Page 14

 

 

CA3-­‐‑OM-­‐‑V615

 

   

   

   
   

   

What   is   covered?      

This   Warranty   covers   any   defects   in   materials   or   workmanship   when   the   product   is   installed   and   operated   according   to   
these   written   installation   instructions,   subject   to   the   terms   within   this   Limited   Warranty.      This   Warranty   applies   only   to   

products   that   are   installed   in   accordance   with   the   National   Electric   Code,   all   applicable   plumbing   codes,   all   local   ordinances   
and   regulations   and   these   installation   instructions.      Improper   installation   may   void   this   Warranty.      This   Warranty   extends   to   
the   original   purchaser   and   subsequent   owners,   but   terminates   if   the   product   is   reinstalled   at   a   new   location.         

   

How   long   does   coverage   last?      

Item

   

Initial   Warranty   Period:         
   

Extended   Warranty   Period   

Tank   

Three   Years

   

After   Three   up   to   Five   Years*   

Element   

Three   Years

   

   

Circuit   Board   

Eighteen   Months   

After   18   Months   up   to   Five   Years*   

Other   Electronic   Components   

Eighteen   Months   

   

All   other   Components   

One   Year   

   

*Subject   to   replacement   charge   not   to   exceed   25%   of   the   current   MSRP   of   the   complete   product   (Five   Years   Commercial)   

   

Replacements   and/or   parts   furnished   under   warranty   carry   only   the   unexpired   portion   of   the   original   warranty   or   90   days   
whichever   is   longer.      All   costs   for   shipping   and   handling   are   NOT   included   in   this   warranty   including   the   cost   of   return.      
Seisco   may   require   a   deposit   to   ensure   the   return   of   defective   items   when   advance   shipping   of   replacements   are   
requested.         

   

What   will   Seisco   do?      

Subject   to   the   terms   and   limits   of   coverage   listed   above,   Seisco   will   replace   any   component   that   is   defective   in   materials   or   
workmanship   and   pay   reasonable   labor   charges   associated   with   the   replacement   as   set   forth   as   follows:      All   repair   parts   
must   be   genuine   Seisco   parts.      All   repairs   or   replacements   must   be   performed   by   an   individual   or   servicing   company   that   is   

properly   trained,   qualified   or   licensed   to   do   the   type   of   repair.      Only   Seisco   can   authorize   the   replacement   of   the   product.      If   
a   component   or   product   returned   to   Seisco   is   found   to   be   free   of   defects   in   material   or   workmanship   the   warranty   claim   
may   be   denied.         

   

How   do   I   get   service?      

You   must   contact   Seisco   or   an   authorized   service   provider   for   the   repair   of   a   product   under   this   Warranty.      For   the   name   of   
a   service   provider   please   contact   your   place   of   purchase,   visit   the   Seisco   website   (www.seisco.com),   or   contact   Seisco.      
Receipt   of   registration   by   Seisco   will   constitute   proof-­‐of-­‐purchase;   registration   is   not   necessary   in   order   to   validate   this   
Warranty.         

   

What   is   not   covered?      

   

This   Warranty   does   not   cover   any   failures   or   operating   difficulties   due   to   accident,   abuse,   misuse,   alteration,   
misapplication,   force   majeure,   improper   installation   including   failure   to   install   properly   sized   drain   pan   with   drain   hole   at   
least   1”   in   diameter   under   unit,   improper   maintenance   or   service,   inadequate   water   quality,   scale   buildup,   freeze   damage,   
or   for   any   other   causes   other   than   defects   in   materials   or   workmanship.      This   Warranty   does   not   apply   to   any   product   
whose   serial   number   or   manufacture   date   has   been   defaced.      This   Warranty   does   not   cover   any   product   when   used   for   

other   than   its   intended   purpose.      This   warranty   does   not   apply   if   the   unit   is   not   property   installed   in   compliance   with   the   
National   Electric   Code,   all   applicable   plumbing   codes,   all   local   ordinances   and   regulations   and   these   installation   instructions.         

   
   

Seisco   is   not   liable   for   any   special,   incidental,   indirect   or   consequential   damages   that   may   arise,   including   damage   to   person   
or   property,   loss   of   use,   or   inconvenience.      Some   states   do   not   allow   the   exclusion   or   limitation   of   incidental   or   
consequential   damages,   so   the   above   limitation   may   not   apply   to   you.         

   

Limitation   on   implied   warranties      

   

Any   implied   warranties   of   merchantability   and   fitness   arising   under   state   law   are   limited   in   duration   to   three   years,   
unless   the   period   provided   by   state   law   is   less.      Some   states   do   not   allow   limitations   on   how   long   an   implied   Warranty   
lasts,   so   the   above   limitation   may   not   apply   to   you.      This   Warranty   gives   you   specific   legal   rights,   and   you   may   also   have   
other   rights   that   vary   from   state   to   state.      

   

   

FIVE   YEAR   LIMITED   COMMERCIAL   WARRANTY

   

Summary of Contents for CA-10-208-3P

Page 1: ...ANTY SHALL BE VOID IF THE UNIT HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES DUE TO FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES THE INSTALLATION MUST CONFORM TO ALL INSTRUCTIONS IN THIS MANUAL AND TO ALL LOCAL AND NATIONAL CODES IF YOU HAVE ANY QUESTIONS OR REQUIRE ANY ASSISTANCE WITH...

Page 2: ...SING CORRECTLY RATED WIRES AND CIRCUIT BREAKERS FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR CONSULT QUALIFIED PERSONNEL HAZARD OF ELECTRICAL SHOCK BEFORE REMOVING THE COVER OR SERVICING THE UNIT MAKE SURE THE ELECT...

Page 3: ...eral Safety Inside Cover Introduction to the SEISCO WATER HEATER 1 Features and Benefits 2 DOs and DON Ts 3 Installation Guide 4 Electrical Installation 6 Limited Warranty 11 Warranty Claims Procedure 12 Troubleshooting Guide 13 Product Specifications 14 Parts Diagrams 15 Wiring Diagrams 17 Service Warranty Information Back Cover ...

Page 4: ...ictorian period are inherrently inadequate for the lifestyle enjoyed by most of the Western world Only in the past several years has technology advanced to the point that Metal parts used in demanding applications can be replaced with glass fiber reinforced heat stabilized nylon resin Micro control has reached a new high level of speed and proficiency The SEISCO uses a patented technology that com...

Page 5: ...high sulfur content water in water heating applications ANOTHER WAY YOU SAVE Because of the state of the art design you can expect a long service life from the heater components All maintenance even major requirements including replacement of the electronic control board can easily be diagnosed and completed in minutes In the unlikely event you do have a problem the ten year limited warranty READ ...

Page 6: ...ers NEVER POUR OR SPRAY LIQUIDS DIRECTLY ON THE UNIT THAT MIGHT ENTER THE CASE POSSIBLY CAUSING DAMAGE TO YOUR UNIT Your SEISCO is designed for safe operation and ease of service Qualified service personnel must service your unit only BEFORE YOUR UNIT IS TO BE SERVICED ALWAYS TURN OFF ALL MAIN POWER CIRCUIT BREAKERS TO THE UNIT After servicing always RUN WATER through your unit before turning the ...

Page 7: ...ection of plywood 20 x 20 inches square to the wall first then use wood screws to attach the water heater to the plywood PROPERTY DAMAGE PROTECTION WHEN INSTALLING THE SEISCO IN ANY AREA WHERE LEAKS OF ANY NATURE COULD CAUSE PROPERTY DAMAGE OR ANY OTHER AREAS THAT ARE NOT READILY VISIBLE OR ROUTINELY MONITORED INCLUDING CLOSETS CABINETS ATTICS A DRAIN PAN AT LEAST 3 DEEP WITH 1 DIAMETER MINIMUM DR...

Page 8: ... and or pressure relief valve discharges periodically this may be due to thermal expansion in a closed water supply system Contact the water supplier or local plumbing inspector on how to correct this situation Do not plug the relief valve DRAIN PAN The Seisco heater must be located in an area where water leakage of the unit or connections will not result in damage to the area adjacent to the appl...

Page 9: ...S WATER HEATER MUST BE INSTALLED TO MEET THE CURRENT NATIONAL ELECTRIC CODE AND ANY APPLICABLE LOCAL PLUMBING ELECTRICAL HEATING AND AIR CONDITIONING CODES Install wiring see wiring diagram from the unit to the Main Power Circuit Breaker Panel Connect the wiring to the unit as shown on the wiring diagram attached to the inside of the unit s cover WIRING OPTIONS Three Phase Models ELECTRICAL INSTAL...

Page 10: ...al wires entering the heater from the side 3 Mounting Height For safety ease of installation and service the suggested height above the floor is 42 to 48 inches minimum 10 inches Do not install electrical disconnect or sub panels below heater as this may interfere with access to the clean out plates located under the heater 4 Front Clearance In the absence of a door or removal access panel in fron...

Page 11: ...d USE EXTREME CAUTION WHEN CHECKING VOLTAGE TO THE UNIT Check the voltage available to each active power circuit OPERATIONAL CHECKS Turn water on MEDIUM LOW utilizing any sink allowing water to run for a couple of minutes to ensure that all air is purged from the unit You will hear a click as the relays on the circuit board engage It is normal to hear a hissing or crackling noise from the heat exc...

Page 12: ...it breakers are not turned on especially heaters with multiple circuits Incoming power wires to the water heater are out of phase heaters with multiple circuits Water supply valve not turned on no water in the heater chamber Water supply lines are reversed hot and cold reversed Water supply connection s are leaking T P Relief Valve where required by local code is leaking or stuck open THE SEISCO H...

Page 13: ...e electrical capacity of the home or building when selecting multiple Seisco heaters for a high flow application Refer to the Electrical Service Requirements and Sample Load Calculations section in the Product Guide Typical Flow Use Rates in Gallons per Minute GPM Fixture Type Lavatory Bathtub Shower Kitchen Sink Pantry Sink Laundry Sink Dishwasher Flow Rates 0 5 1 5 2 0 4 0 1 5 3 0 1 0 1 5 1 5 2 ...

Page 14: ...eturned to Seisco is found to be free of defects in material or workmanship the warranty claim may be denied How do I get service You must contact Seisco or an authorized service provider for the repair of a product under this Warranty For the name of a service provider please contact your place of purchase visit the Seisco website www seisco com or contact Seisco Receipt of registration by Seisco...

Page 15: ... power Check power panel Reset breaker if tripped Call local service contractor Call local service contractor Hot water temperature fluctuates FLOW is too high ONE OF THE MAIN POWER BREAKERS may be tripped BAD Heating Element BAD Temperature Sensor Reduce flow Check power panel Reset breaker if tripped Call local service contractor Call local service contractor Do not attempt to fill a large batht...

Page 16: ...5 15 6 23 lbs Model Number Kilowatts KW Voltage VAC AMPS Phase Wire Size Model Chambers CA 10 208 3P 10 1 208 28 10 2 CA 14 208 3P 13 5 208 37 8 2 CA 18 208 3P 18 0 208 50 6 2 CA 21 208 3P 21 0 208 58 6 2 CA 12 480 3P 12 480 14 14 2 CA 15 480 3P 15 480 18 14 2 CA 21 480 3P 21 480 25 12 2 CA 24 480 3P 24 480 29 10 4 CA 27 480 3P 27 480 32 8 4 Use conductors rated for 75 C ...

Page 17: ...et Water Tube NPT 9 Transformer 10 Heating Element Relays 3 ea 11 LED Light Indicator 12 Audible Speaker 13 Output Temperature Control 14 Microprocessor Control Chip LEGEND 15 Button Manual Audible Activation 16 Triacs 3 each 17 Copper Heat Sink Tube 18 Power Connection Lugs 208 240 VAC TH IN Inlet Temperature Sensor TH 1 Chamber Temperature Sensor 1 TH 2 Chamber Temperature Sensor 2 FOUR CHAMBER ...

Page 18: ...ement Relays 3 7 Transformer 8 LED Light Indicator 9 Audible Speaker 10 Output Temperature Control 11 Microprocessor Control Chip 12 Blue Button Manual Audible Activation LEGEND 14 Triacs 2 15 Triac Mounting Blocks to Heat Sink 2 16 Copper Heat Sink Tube 17 Power Connection Lugs 208 480 VAC TH IN Inlet Temperature Sensor TH 1 Chamber Temperature Sensor 1 TH 2 Chamber Temperature Sensor 2 TWO CHAMB...

Page 19: ...________________ ______________________________________________ ______________________________________________ NOTES AND SERVICE Your SEISCO can be serviced by most major brand authorized appliance repair or heating and plumbing centers in your area If your preferred service center does not already have service information Seisco International LLC will upon request and with no charge promptly fax ...

Page 20: ...CA3 OM V615 SEISCO INTERNATIONAL LLC 241 Airtex Dr Houston TX 77090 Toll Free 888 296 9293 Phone 281 876 3300 Fax 281 876 3338 seisco com ...