Minimum headroom
Installation on lintel
Installation on ceiling
When mounting as shown in the
diagrams at right, make sure there
are at least 35 mm (1,37") of head-
room between the ceiling and highest
point reached by the door while pivoting.
Installation without the minimum headroom of 35 mm
If there is not enough room to leave the minimum headroom of 35 mm, then the opener
must be mounted with a drawbar extension (available as an optional extra).
Extension piece
Procedure
Mounting
Installation Instruction UK
-
Page 3
35 mm
Minimum headroom
Lintel attachment angle
Mount the lintel attachement
angle above the middle of
your garage door, either on
the lintel or on the ceiling.
Make sure to leave the
required minimum headroom.
Emergency release
The Bowden pull-wire for the
emergency release must be
attached to the garage door.
Handle in such a way that it is
pulled downwards when the
handle is turned.
Attaching the drive unit
When attaching the drive unit
to the ceiling, we recommend
placing a ladder underneath
it.