REMARKS ON INSPECTION AND MEASUREMENT

l

  Current consumption

   For the whole movement 

:  Less than 0.22 

μ

A (with voltage supplied from a battery)

   For the circuit block alone 

:  Less than 0.16 

μ

A (with voltage supplied from a battery)

1.  Remove the solar cell holder and solar cell.
2.  Remove the rechargeable battery unit, and then, reassemble the circuit block, circuit block cover 

and two circuit block cover screws.

 

(As a result, only the rechargeable battery is removed from the movement.)

3.  Apply the probes of the tester as shown in the illustration below.

Note:  When applying the minus probe of the tester, take care not to short-circuit the minus probe 

and circuit block cover.

4.  After checking that a stable measurement is obtained with the tester connected, read the current 

consumption. (As the hands move at 20-second intervals, 3 to 5 minutes may be required before a 
stable measurement is obtained.)

l

  Value checking - coil resistance (coil blocks)

l

  How to measure the current consumption for the whole movement

Note: If the measurement value remains high 

or unstable, shut out the light from the 
movement, and make a measurement 
again.

5.  Wait until a stable measurement becomes available. 

It usually takes 30 seconds to a few minutes for 
getting a stable measurement. 

6.   Make sure that the read value is less than 0.80 

μ

A.

*  When  measuring  the  current  comsumption  using 

the SEIKO digital multi-tester (S-860), use the range 
of 40 

μ

A of SUPPLy V (=1.55V) & GATE TIME 2S).

COIL BLOCK   4002 909      1.70K

Ω

 - 2.60K

Ω

Summary of Contents for V115A

Page 1: ...nd intervals 4002 909 1 70 2 60 K Circuit block Less than 0 16 A Movement Less than 0 22 A Time setting hand position adjustment resetting the circuit Free Outside 15 55 mm x 11 80 mm Casing 15 15 mm...

Page 2: ...le battery decreases it is necessary to have the watch repaired Environment Light source Illumination lux Time required for full charge Time required for steady operation Time to charge 1 day of power...

Page 3: ...screw 1 pc 5 4025 547 Solar cell 6 4246 644 Solar cell lead terminal 7 0491 735 Dial washer 4 0866 Holding ring for dial 8 0271 946 Hour wheel Disassembling procedures Figs 1 27 Reassembling procedure...

Page 4: ...block cover screw 10 4461 534 Circuit block cover 25 0282 804 Clutch wheel 26 4239 909 Rotor stator 27 0100 969 Main plate 22 0389 909 Setting lever spring 23 0383 806 Setting lever 24 Setting stem 18...

Page 5: ...sponding parts 3 DIAL SHEET 8700 The type of DIAL SHEET is determined based on the design of cases and some models do not need it Check the case nuumber and refer to the Parts Catalogue web site to ch...

Page 6: ...ll Set the 4 notched portions of the DIAL into the guide protrusions of the HOLDING RING FOR DIAL 3 DIAL SHEET 8700 How to install Set the 4 notched portions of the DIAL SHEET into the Guide protrusio...

Page 7: ...a scratch or damage IncasetheperformanceoftheSOLARCELLdoesnotsatisfythestandardwhichismentionedafterchecking page 13 Output of voltage for the solar cell unit please replace the SOLAR CELL with a new...

Page 8: ...hargeable battery unit will be deteriorated Never wash the rechargeable battery unit as it is an electronic part Rechargeable battery unit Guide post A portion of the lead terminal B portion of the le...

Page 9: ...ion and lubricating Refer to the illustrations below for the setting position and lubrication of the respective wheels Lubriccating Types of lubricant Watch oil AO 3 Watchi oil AO 2 Lubricang quantity...

Page 10: ...ustration below for the setting position and lubrication of the respective parts Have the spring portion of the yoke securely catchtheprotrudedportionofthemainplate A portion in the illustration Note...

Page 11: ...cuit the minus probe and circuit block cover 4 After checking that a stable measurement is obtained with the tester connected read the current consumption As the hands move at 20 second intervals 3 to...

Page 12: ...urement value may be obtained 3 After checking that a stable measurement is obtained with the tester connected read the current consumption Structure of the circuit block Coil output terminal Crystal...

Page 13: ...asshownintheillustration atrighttomeasurethevoltageoftherechargeablebattery before recharge initial voltage 2 Place the watch at a distance of 5 cm under a fluorescent light of 15 to 20 watts and char...

Page 14: ...the table below to determine whether the recharging function is normal or not Initial voltage and guidelines of normal defective decision Initial voltage Guidelines of normal defective decision 0 5 V...

Page 15: ...times Setting mechanism function of the time setting Make sure that it has a click at the 1st click position and the stem is not pulled off Pull out the crown to the 1st click then turn it Setting mec...

Page 16: ...ESIST 20BAR 20 BAR SCUBA DIVER S AIR DIVER S 150 m 18 75 BAR 150 m times 0 125 SCUBA DIVER S AIR DIVER S 200 m 25 BAR 200 m times 0 125 He GAS DIVER S 300 m 37 5 BAR 300 m times 0 125 He GAS DIVER S 6...

Reviews: