8
TECHNICAL GUIDE
Cal. V110A
Note: If the measurement value remains high or unstable, shut out the light from the movement, and
make a measurement again.
+
1.
Apply the probes of the tester as shown in the illustration.
2.
Shut out the light from the circuit block.
How to measure the current consumption for the circuit block alone
Note: If the circuit block is exposed to light, an extremely high measurement value may be obtained.
3.
After checking that a stable measurement is obtained with the tester connected, read the current
consumption.
+
●
Output voltage for the solar cell unit
Output voltage when the watch is placed at a distance
of 5 cm under a fluorescent light of 15 to 20 watts
:
More than 2.3 V
1.
Connect the tester to the output terminal of the
solar cell unit as shown in the illustration at
right.
Checking procedure
+