30
(2) Installation of Printer Bracket
Firmly attach the printer bracket with 4 printer attachment screws as shown in the figure below.
The tightening torque should be 39.2 cN•m (4 kgf•cm).
NOTE
◆
Turn off the printer before the operation.
◆
Remove the AC cable of the AC adapter and the interface cable.
(3) Installation of Wall Hanging Bracket
Fix the wall hanging bracket to the mounting surface, and then secure it with 6 wall hanging bracket
attachment screws. WLK-B01-1 is designed to be installed on a wall.
After installation, make sure that the wall hanging bracket is fixed on the wall securely without rattle.
NOTE
◆
The accompanying wall hanging bracket attachment screws are for installing to wood
materials. Do not use them for other materials.