Seiko Grand Seiko SPRING DRIVE DIVERS 9R65 Instructions Manual Download Page 3

54

55

Never use the watch in saturation diving 
using helium gas.

While diving, never operate the watch in any other 
manner than set forth in the instruction manual.

WARNING

WARNING

CAUTION

Before using the diver’s watch, you have to be properly trained in 
various types of diving and possess the requisite experience and skill 
to dive safely. When diving, strictly abide by the rules of diving.

CAUTION

Do not turn or pull out the crown when the watch is wet.

※  Should blur or moisture occur inside the dial glass and persist for a long time, this 

indicates poor waterproof capability. Consult the retailer from whom the watch 
was purchased or SEIKO CUSTOMER SERVICE CENTER as soon as possible.

Water may get inside of the watch.

Do not leave moisture, sweat and dirt on the watch for a long time.

Do not wear the watch while taking a bath or a sauna.

CAUTION

Be aware of a risk that a water resistant watch may lessen its water 

resistant performance because of deterioration of the adhesive on the 

glass or gasket, or the development of rust on stainless steel.

Steam, soap or some components of a hot spring may accelerate the 

deterioration of water resistant performance of the watch.

56

57

■ PRECAUTIONS FOR DIVING (PLEASE MAKE SURE TO OBSERVE THE FOLLOWING.)

● Before diving

Before diving, check the following:

1.The time is correctly set.

2. The power reserve indicator shows the level of remaining 

power not less than one-half. If the remaining power 
shows less than one-half, manually wind the mainspring.

3. The rotating bezel turns smoothly. (The bezel 

rotation must not be too loose or too tight.)

⇒ ● “How to read the power reserve indicator” page 69
⇒ ■ “HOW TO WIND THE MAINSPRING” page 66

⇒ ■ “ROTATING BEZEL” page 62

⇒ ■ “NAMES OF THE PARTS AND THEIR FUNCTIONS” page 60.

4.The crown is completely screwed in.

5. There are no visible cracks or scratches on the 

dial glass or band.

6. The band is firmly attached to the watch (with 

spring bars, clamp or other parts.)

⇒ ● “Screw lock type crown” page 61

1

2

3

4

5

6

CAUTION

If there are any malfunctions, contact the retailer from whom the watch was purchased or SEIKO CUSTIMER SERVICE CENTER.

58

59

● While diving

● After diving

Please observe the following cautions for use.

Please follow the care instructions below after diving.

Rinse the watch in fresh water to wash out 
all seawater to prevent rust from forming.

After rinsing the watch, wipe it 
thoroughly dry.

Wear the watch in air (scuba) diving 
within the water depth of 200 meters.

Do not operate the crown when the 
watch is in water.

Take care not to bump the watch against 
hard objects such as rocks.

Bezel rotation may become slightly harder 
in the water but this is not a malfunction.

60

61

L


:Crown at the locked position

: Crown unlocked at the 0 position for 

manual winding of the mainspring

:First click position for date setting
:Second click position for time setting

※ It is necessary to unlock the screw lock type crown before operating it.
※ In order to prevent any operational errors from occurring, once you have finished operating the crown, make sure to relock it.

The watch features a screw-lock mechanism that can securely lock the crown when it is not being operated in order to prevent any operational errors and to improve the water resistant property.

0 

1 

Confirmation line

CAUTION

When locking the crown, turn it slowly with care, ensuring that the screw is properly engaged. 
Be careful not to forcibly push it in, as doing so may damage the screw hole in the case.

To unlock the crown

Turn  the  crown  counterclockwise 

(downward) to unscrew it. When you 

see the red line, the crown can be operated.

To lock the crown

Turn  the  crown  clockwise 

(upward) while gently pressing 

it in toward the watch body until it stops.

■ NAMES OF THE PARTS AND THEIR FUNCTION

※ The orientation and design of the display may vary depending on the model.

● Screw lock type crown

● Basic mechanism

Minute hand

Hour hand

Second hand

Power reserve indicator

Calendar

Crown

Rotating bezel

page 62

page 68

Summary of Contents for Grand Seiko SPRING DRIVE DIVERS 9R65

Page 1: ...付修正について 28 より正確に時刻を合わせるために 30 使用上の注意とお手入れのしかた 31 性能と型式について 32 ルミブライトについて 33 耐磁性能について 磁気の影響 34 時計に影響を及ぼす身のまわりの磁気製品 35 バンドについて 36 アフターサービスについて 38 補修用性能部品について 39 分解掃除による点検調整 オーバーホール について 40 こんなときは 42 目 次 製品の特長 5 製品取扱上のご注意 6 潜水に際しての注意事項 必ずお読みください 10 潜水前 10 潜水中 12 潜水後 13 各部の名称と主なはたらき 14 基本部分について 14 ねじロック式りゅうずについて 15 回転ベゼルについて 16 回転ベゼルの使いかた 17 ダイバーアジャスターの使いかた 18 ぜんまいの巻き上げについて 20 巻き上げのめやす 20 ...

Page 2: ...and proper and safe use of the Grand Seiko please read the instruction manual carefully before use We thank you in advance for long time regular use of our product Keep this manual handy for easy reference as necessary For the details of the Spring Drive mechanism refer to the separate volume Spring Drive Handbook Spring Drive works by the power provided by the mainspring Remember to check the pow...

Page 3: ...d is firmly attached to the watch with spring bars clamp or other parts Screw lock type crown page 61 1 2 3 4 5 6 CAUTION If there are any malfunctions contact the retailer from whom the watch was purchased or SEIKO CUSTIMER SERVICE CENTER 58 59 While diving After diving Please observe the following cautions for use Please follow the care instructions below after diving Rinse the watch in fresh wa...

Page 4: ...g watch equipped with a manual winding mechanism When the watch is worn on the wrist the motion of your arm automatically winds the mainspring of the watch How to manually wind the mainspring by turning the crown In order to set the time and date after winding the mainspring manually do not relock the crown but continue the procedures How to set the date and time page 70 Guide for winding state of...

Page 5: ...ainspring is sufficiently wound and the watch is working When setting the date and time ensure that the watch is working 4 Pull out the crown to the first click The second hand continues moving Pull out the crown to the first click 2 Unlock the crown Screw lock type crown page 61 3 While the watch hands show any time between 9 00 PM and 1 00 AM pull out the crown to the second click and turn it co...

Page 6: ... the band itself Adjust the band with a little clearance with your wrist to ensure proper airflow Make a room for one finger around your wrist when you wear the watch Band The band touches the skin directly and becomes dirty with sweat or dust Therefore lack of care may accelerate deterioration of the band or cause skin irritation or stain on the sleeve edge The watch requires a lot of attention f...

Page 7: ...rating The mainspring has not been wound The watch stops even though the power reserve indicator is not showing 0 The watch has been left at a low temperature below 0ºC Wrong display of the time and or date The watch temporarily gains or loses time The watch has been left at an extremely high or low temperature The watch has been left close to an object generating a strong magnetic field You dropp...

Reviews: