While in the All-Segments-Light-Up mode, if Button D is pressed , EL backlight illuminates the
display for 2 to 3 seconds.

★★

While in the Buzzer mode, if Button C is pressed, the buzzer rings for 5 to 6 seconds, and if Button
D (SET button) is kept pressed for 5 to 6 seconds, the display returns to the normal TIME/
CALENDAR display.

2. Pressure Sensor

Remarks on atmospheric pressure

Pressure index value is determined by the following calculation.

Pressure index value = Output value from sensor – Offset value

In the case of the display in Illustration 2,

Pressure index value = 1452 – 1281 = 171

so the pressure index value is 171.

In order to calculate the atmospheric pressure out of the pressure index value, the caluculation is
as follows.

Atmospheric pressure (hPa) = ( Pressure index value + 5 ) x 2.5 + 550

In the case of the display in Illustration 2,

Atmospheric pressure (hPa) = ( 171 + 5 ) x 2.5 + 550 = 990 (hPa)

so the atmospheric pressure is 990 hPa.

TECHNICAL GUIDE

Cal. DH33A

1. How to set the watch to the TEST mode.

To show the "TEST mode", reset the circuit while keeping Button A (MODE button) and Button C
(SELECT button) pressed. (See Illustration 1 and 2.) If this is not done properly, the display becomes
blank or return to the normal TIME/CALENDAR display. (To reset the circuit, refer to “I. REMARKS
ON BATTERY CHANGE” on page 3.)

Illustaration 1

Button C

Button A

Offset value

Output value
from sensor

Illustaration2 - Offset

While in the TEST mode, the mode changes as follows with each press of Button A.

All-Segments-

light-up mode

Temperature

mode

Atmospheric pressure/

Water depth mode

Normal Time/Calendar mode

A

A

A

A

D

Press for 5 to 6
seconds

Buzzer mode

★★

Summary of Contents for DH33A

Page 1: ...tz Tester Any gate can be used Loss Gain Regulation System Monthly rate at normal temperature range less than 15 seconds Trimmer condenser DIVE PLAN display Daily Alarm function NITOROX Diving functio...

Page 2: ...00 000 c s Normal quantity Cal DH33A Please refer to II REMARKS ON DISASSEMBLING AND REASSEMBLING 1 Case back screw Piezoelectric element 2 Case back 5 6 Module 10 Case Button C Button D Gasket for se...

Page 3: ...by using the adhesive Use the LOCTITE 241 of Loctite Corporation to fix the screws Never use any other adhesive but LOCTITE 241 in the market place or any joining material for band adjustable screw S...

Page 4: ...e tip of the sensor unit board while passing it through the hole Caution Never touch the gel portion of the sensor 3 Set the sensor unit firmly to the set position of the case 4 Put the sensor unit cl...

Page 5: ...t Functional Checks After replacing module with a new one Cal DH33 requires checks for the accuracy of data such as 1 water depth measurement 2 pressure index value and 3 temperature measurement Those...

Page 6: ...n is as follows Atmospheric pressure hPa Pressure index value 5 x 2 5 550 In the case of the display in Illustration 2 Atmospheric pressure hPa 171 5 x 2 5 550 990 hPa so the atmospheric pressure is 9...

Page 7: ...043 1040 1038 1035 1033 1030 1028 185 184 183 182 181 180 179 178 177 176 175 174 173 172 171 170 169 168 167 166 165 164 163 162 1025 1023 1020 1018 1015 1013 1010 1008 1005 1003 1000 998 995 993 990...

Page 8: ...Press Button A several times to show the TIME CALENDAR mode 2 Press Button B only once to change the display to the TIME SETTING mode 3 While in the TIME SETTING mode press Button C first and while ke...

Reviews: