ELE
ELE
ELE
ELECTRIC STOVE
CTRIC STOVE
CTRIC STOVE
CTRIC STOVE INSTALLATION
INSTALLATION
INSTALLATION
INSTALLATION
Grounding Instructions
This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for
the electric current to reduce the risk of electric shock. This product is equipped with a cord with an equipment-grounding
conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. If the plug does not fit the
outlet, have a proper outlet installed by a qualified electrician.
This product is for use on a nominal 120V circuit and has grounding plug that looks like that plug illustrated below. Make
sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with
this product.
NOTE: A 15AMP,120 Volts circuit is required. Dedicated circuit is preferred but not essential in all cases, a dedicated
circuit will be required if, after installation, the circuit breaker trips or the fuse blows on a regular basis when the heater is
operating. Additional appliance on the same circuit may exceed the current rating of the circuit break.
WARNING:
1
Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power
cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons.
2. Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to
reduce the risk of fire, electric shock and injury to persons.
3. Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons,
always use a licensed electrician.
BEFORE USING THIS APPLIANCE:
1. Please check the circuit break for this appliance to make it’s on
2. Light bulbs may become loose during shipping, if the flame effect is dim or does not operate properly at first,
ensure that the light bulbs are properly secured in the sockets(bulbs should be finger tight, don’t over tighter) see
“Replacing Light Bulb” section of this manual for instructions.
3. The information regarding this appliance can be found on the rating plate located on the back of the unit
PLUGGING IN THE HEATER:
1. Make sure the appliance main “
I
/O” is switch OFF(refer to operating instruction section)
2. Plug the unit into a no less 15Amp/120V outlet.
TECHNICAL
TECHNICAL
TECHNICAL
TECHNICAL S
S
S
SPECIFICATIONS
PECIFICATIONS
PECIFICATIONS
PECIFICATIONS
Model#
EA1103A
Rate Voltage
AC 120V, 60Hz
Rate Power(Total)
1400W
Power of Heating Apparatus
650W/1300W
Flame Power
80W
Motor Power
20W
Specification of the Bulb
2 pcs E12