Section 2: Preflight Safety Check
Safety Checklist
2016 Bambi MAX Operations Manual
(Version C)
4
We Engineer Solutions
11. With power on, check the function of the pumps by pressing the pump’s ON button for four or five
seconds. The pump should turn on and run for the period the button is held. The pump will be
audible within a few feet of the bucket. Listen for abnormal noises that are not consistent with
smooth operation. If you are operating in a noisy environment, you can confirm that the pump is
running by holding your hand on the top of the filter screen. You may also see the shell move each
time you activate the switch.
12. Check the filter screen for debris accumulation and clear as necessary.
13. Check the filter screen for signs of damage that may affect water flow.
Warning
Do not put your fingers or other objects into the pump impeller while the pump is running.
Personal injury or damage to the pump can occur.