- 3 -

your hair, clothing, and gloves away from moving parts.

Loose clothes, jewelry, or

long hair can be caught in moving parts.

-

Avoid accidental starting. Be sure switch is off before plugging in.

Carrying tools

with your finger on the switch or plugging in tools may result in personal injury.

-

Remove adjusting keys or switches before turning the tool on.

A wrench or a key

that is left attached to a rotating part of the tool may result in personal injury.

-

Do not overreach. Keep proper footing and balance at all times.

Proper footing and

balance enables better control of the tool in unexpected situations.

-

Use safety equipment. Always wear eye protection.

Dust mask, non-skid safety shoes,

hard hat, or hearing protection must be used for appropriate conditions.

1.4 Tool use and Care

-

Use clamps or other practical way to secure and support the workplace to a

stable platform.

Holding the work by hand or against your body is unstable and may

lead to loss of control.

-

Do not force tool. Use the correct tool for your application.

The correct tool will do

the job better and safer at the rate for which it is designed.

-

Do not use tool if switch does not turn it on or off.

Any tool that cannot be

controlled with the switch is dangerous and must be repaired.

-

Disconnect the plug from the power source before making any adjustments,

changing accessories, or storing the tool.

Such preventive safety

-

Store idle tools out of reach of children and other untrained persons.

Tools are

dangerous in the hands of untrained users.

-

Maintain tools with care

.

Keep cutting tools sharp and clean.

Properly maintained

tools, with sharp cutting edges are less likely to bind and are easier to control.

-

Check for misalignment or binding of moving parts, breakage of parts, and any

other condition that may affect the tools operation. If damaged, have the tool

serviced before using.

Many accidents are caused by poorly maintained tools.

-

Use only accessories that are recommended by the manufacturer for your model.

Accessories that may be suitable for one tool, may become hazardous when used on

another tool.

1.5 SERVICE

-

Tool service must be performed only by qualified personnel.

Service or maintenance

performed by unqualified personnel could result in a risk of injury

-

When servicing a tool, use only identical replacement parts. Follow instructions in

the Maintenance section of this manual.

Use of unauthorized parts or failure to follow

Maintenance instructions may create a risk of electric shock or injury.

Summary of Contents for PYF100N

Page 1: ...2013 06 21 Products by CE certificate Instruction Manual YF series BLDC Screwdriver Usage Micro oven Refrigerator Washing Machine Automobile home appliances assembly...

Page 2: ...Specification 8 4 2 Available bit socket 8 4 3 Torque curve at maximum speed 8 4 4 Information by LED display 9 4 5 Dimensions 11 5 Controller 5 1 Specification 11 5 2 Overload overheat protection 11...

Page 3: ...s should electrically malfunction or break down grounding provides a low resistance path to carry electricity away from the user Avoid body contact with grounded surface ad pipes radiators ranges and...

Page 4: ...s not turn it on or off Any tool that cannot be controlled with the switch is dangerous and must be repaired Disconnect the plug from the power source before making any adjustments changing accessorie...

Page 5: ...flammer les poussi res ou les vapeurs Tenez distance les curieux les enfants et les visiteurs pendant que vous travaillez avec un outil lectrique Ils pourraient vous distraire et vous faire une fausse...

Page 6: ...eveux longs risquent d tre happ s par des pi ces en mouvement M fiez vous d un d marrage accidentel Avant de brancher l outil assurez vous que son interrupteur est sur ARR T Le fait de transporter un...

Page 7: ...endommag faites le r pqrer avant de vous en servir De nombreux accidents sont caus s par des outils en mauvais tat N utilisez que des accessoires que le fabricant recommande pour votre mod le d outil...

Page 8: ...feature Torque repeatability 3 300 1700 rpm Motor efficiency 85 Low noise heat and less energy consumption Over heat Overload Over voltage protection circuit LED display ESD free on bit socket Conduc...

Page 9: ...Model Screw Start Torque Kgf cm Speed rpm Weight Kg Bit YF30N M2 6 M5 Lever 7 30 500 1 700 0 7 Hex 1 4 Hex 5mm A B YF45N M3 M6 10 45 500 1 200 0 7 YF90N M4 M8 10 90 300 700 0 75 YF30NP M3 M6 PUSH 7 3...

Page 10: ...of motor RED Light On Off blink 0 5s Auto reset lower than 80 4 Driver Lock by external signal RED Light On continuously Reset by signal off YF45N YF45NP 1 2 3 4 5 6 7 8 YF90N YF90NP 1 2 3 4 5 6 7 8...

Page 11: ...10 4 5 Dimensions YF30N YF45N YF90N YF30NP YF45NP YF90NP PYF35N PYF505N PYF100N...

Page 12: ...wer Recovery Turn off the power switch and on after 1 min Turn the power switch off and on at lower than 90 temperature Model YFC 35D Safety certificate CE by MET EC countries Rated Input 230 VAC 50 6...

Page 13: ...n Once it is logged in it is effective until the power OFF button By pressing the MODE button it circulate Auto Log in and Parameter mode Auto means operating Before parameter mode password required E...

Page 14: ...st t Display the temperature of driver inside unit 0 1 2nd F The latest Fastening time unit mS 3rd L The latest Loosening time unit mS 4th Pc The latest current value unit 0 1A 5th tu The latest Faste...

Page 15: ...model the min and max speed is automatically limited according to the specification 6 2 3 Loosing speed L_SPD P3 Change rotation speed for reverse loosening Depend on the selected model the min and ma...

Page 16: ...stop in turn from 0 to 9999 unit 0 1 turn 6 2 10 Multi_3 Holding time for next step of operation hLd ti P10 Time setting of holding to next step from 0 to 99 unit 0 1 sec 6 2 11 Display setting dSP M...

Page 17: ...P15 All parameter will be changed to it s original torque setting Password is 77 6 2 16 Firmware version display VEr P16 7 I O details 7 1 Port on back panel Firmware Upgrade select Screw Counter Sco...

Page 18: ...TE START YFC 35 MOTOR RUN TORQUE UP 1 2 3 4 5 OUT COM OUT IN Pin no In Out Interface 1 OUT Torque Up 2 Motor Run 3 Out COM 4 IN Remote Start 5 Driver Lock 6 X 7 8 IN Reverse rotation 9 In COM 8 9 DRIV...

Page 19: ...ot connected Check the cable connection 2 111 SMPS fault The power supply system will be shut down by overload Turn off the power and On again after 1 min 3 112 Overload protection Automatic reset ref...