17
www.seuservice.com
When the game machines of a same or similar type are installed side by side, their sensors may
interfere with each other. To reject the interference, follow the procedure below.
The following game machines employ a same or similar type of sensor. If interference happens
to the sensors, operation of the games may be mutually disturbed.
• THE HOUSE OF THE DEAD 2, U/R type, DX type and Super DX type
• THE LOST WORLD, U/R type, DX type and Super DX type
• BRAVE FIRE FIGHTERS
• SAMBA DE AMIGO
• CONFIDENTIAL MISSION, U/R type and DX type
• SHAKATTO TAMBOURINE
• THE MAZE OF THE KINGS, U/R type and DX type
Locate an interference rejection wire inside the cabinet.
If the game machines of a same or similar type are installed side by side, place them alternately
(place the machine with an interference rejection wire next to the machine without).
PHOTO 6. 8
●
In order to prevent electric shock and short circuit hazards, be sure to turn
power off before performing work.
●
Be careful not to damage the wires. Damaged wires may cause electric shock
or short circuit or present a fire risk.
●
Do not expose the IC BD, etc. without a good reason. Failure to observe this
can cause electric shock hazard or malfunctioning.
●
Work should be performed by the Location's Maintenance Man or technical
personnel. Performing work by those who do not have technical knowledge
and expertise can cause electric shock accident or malfunctioning.
THE INTERFERENCE PREVENTION WIRING
INTERFERENCE PREVENTION WIRING
SPY-60019
WARNING!
1
*NOTE: Picture may differ from actual unit.
Summary of Contents for Ghost Squad
Page 2: ...VISIT OUR WEBSITE Now with a new look to make your experience that much easier ...
Page 78: ...71 www seuservice com ...
Page 79: ...72 www seuservice com COIN DOOR ...
Page 80: ......
Page 83: ......
Page 86: ...79 www seuservice com CONTROL UNIT CTF 2100 D 1 2 ...
Page 89: ...82 www seuservice com White text ...
Page 90: ...Notes ...
Page 92: ...SEGAAMUSEMENTS USA INC ...