SEQUENCER WITH
DIFFERENTIAL PRESSURE
SWITCH
Technical notice
FI 72.0567.0221E
Page 17 / 45
Sequencer / filter configuration (1/4):
Display of general parameters on the filter configuration
1.
Type of declogging: ONLINE or OFFLINE
2.
Number of cells constituting the filter
3.
Number of declogging solenoid valves per cell
4.
Number of slave boxes required to manage the declogging sequence
5.
Number of compressed air tanks constituting the filter
6.
Total number of declogging solenoid valves constituting the filter
7.
With or without dust emission check option
This option consists in checking that there is no appearance of dust emission downstream of the
filter.
8.
If the dust emission check option is integrated, display of the number of probes fitted on the filter.
Parameters 1 to 8 cannot be modified, they are defined during the project.
9.
Setting the type of stop of the cleaning cycle
When the SFX+V2 loses the run orders, the cleaning cycle has 2 stop modes:
•
Stop "on cycle": the SFX+V2 stops the declogging cycle as soon as the run order is lost.
The cycle will resume where it was stopped when the run order is present again.
•
Stop "end of the cycle": the SFX+V2 finishes the current cycle and stops.
Access in maintenance level
10.
Depends the configuration, forcing the run order from the HMI
Access at manufacturer level
11.
Depends the configuration, forcing the local mode authorisation from the HMI
Access at manufacturer level