-12-
6. Operation
The transmitter has 3 different modes:
●
Test mode:
When the power is on, the transmitter is on the test
mode. It can measure the AC or DC voltage of cable.
When the user presses the TEST/STOP button, the
transmitter will send a high frequency transmission
signal down the cable. When the user presses the
TEST/ STOP button again, the transmitter will stop
sending the transmission signal.
●
Level selection mode:
Press the LEVEL button to enter into the level
selection mode of the transmitter, the LEVEL symbol
will be flashing. User can press
or
button to
select the level of the transmission signal (level: 1~3).
The transmitter will return to the test mode by pressing
the LEVEL button again.
●
Code selection mode:
Press and hold the CODE button for more than 1
second to enter into the code selection mode of the
transmitter, the CODE symbol will be flashing. User
can press
or
button to select the code of the
transmission signal (code: F, E, H, d, L, C, O, A).
Once the code selection is done, the transmitter will
return to the test mode by pressing the CODE button
again.
Summary of Contents for MW9520
Page 1: ...MW9520 CABLE LOCATOR INSTRUCTION MANUAL...
Page 25: ......